Double-Tuned Birdcage Radio Frequency Coil for 7 T MRI: Optimization, Construction and Workbench Validation

被引:0
|
作者
Retico, Alessandra [1 ]
Maggiorelli, Francesca [1 ,2 ,3 ]
Giovannetti, Giulio [4 ]
Boskamp, Eddy [5 ]
Robb, Fraser [6 ]
Fantasia, Marco [7 ]
Galante, Angelo [7 ,8 ,9 ]
Alecci, Marcello [7 ,8 ,9 ]
Tiberi, Gianluigi [10 ,11 ]
Tosetti, Michela [3 ,12 ]
机构
[1] Natl Inst Nucl Phys INFN, Pisa Div, I-56127 Pisa, Italy
[2] Univ Siena, Dept Phys Sci Earth & Environm DSFTA, I-53100 Siena, Italy
[3] Imago7 Fdn, I-56128 Pisa, Italy
[4] Natl Res Council CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[5] Hyperfine Res Inc, Guilford, CT 06437 USA
[6] GE Healthcare Inc, Aurora, OH 44202 USA
[7] Univ Aquila, Dept Life Hlth & Environm Sci MESVA, I-67100 Laquila, Italy
[8] INFN, Gran Sasso Natl Lab, I-67100 Laquila, Italy
[9] Univ Aquila, CNR, SPIN, Dept Phys & Chem Sci, I-67100 Laquila, Italy
[10] London South Bank Univ, Sch Engn, London SE1 0AA, England
[11] Umbria Bioengn Technol UBT Srl, I-06081 Perugia, Italy
[12] IRCCS Stella Maris Fdn, I-56128 Pisa, Italy
关键词
UHF MRI; 7 T MRI; RF coils; double tuned; sodium imaging; TISSUE SODIUM CONCENTRATION; HUMAN BRAIN; MYOCARDIAL-INFARCTION; NA-23; MRI; QUADRATURE; DESIGN; SPECTROSCOPY; MUSCLE; PERFORMANCE; VIABILITY;
D O I
10.3390/electronics12040901
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of the present study is the optimization, construction, and workbench validation of a double-tuned H-1- Na-23 volume radio frequency (RF) coil suitable for human head imaging at 7 T, based on the birdcage geometry. The birdcage-like design which is considered is the four-ring model, in which two standard birdcage-like structures with the same diameters are nested along the longitudinal axis. Simulations based on Maxwell's equations are performed to evaluate the RF magnetic field homogeneity and the RF coil efficiency varying the coil geometrical parameters. The RF magnetic field homogeneity is evaluated both on the transverse (z = 0) and longitudinal (y = 0) planes without performing the impedance matching procedure, so that the RF coil symmetry is not perturbed by the matching network. The RF coil efficiency is instead dependent on the effective coil input RF power, and it is evaluated after matching the coil, so that the reflected power is minimized, assuming that the stimulation power is totally delivered to the RF coil. Considering the simulation results and the target application, the useful RF coil geometrical parameters are fixed. The four-ring model, which showed the best performances, has been built and tested on a workbench, using a cylindrical phantom filled with a 0.05 M saline solution as load. This provides the first example of a four-ring realization intended H-1- Na-23 for human head imaging at 7 T.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Double Band-Pass Birdcage RF Coil for Dual Elements NMR Imaging at 4.7T MRI system
    Ahn, Chang Min
    Sheikh, Faisal Ahmad
    Kim, Yeong Cheol
    Kim, Hyun Deok
    2018 IEEE INTERNATIONAL RF AND MICROWAVE CONFERENCE (RFM 2018), 2018, : 189 - 192
  • [32] Double-crossed radiofrequency coil with improved uniformity for rodent MRI at 7 T
    Marrufo, O.
    Vazquez, F.
    Martin, R.
    Rodriguez, A. O.
    Solis-Najera, S. E.
    JOURNAL OF MAGNETIC RESONANCE OPEN, 2022, 12-13
  • [33] Universal radio-frequency receive-coil connector: Concept and validation at 3 T
    Feuillet, Thomas
    Saint-Jalmes, Herve
    Seurin, Marie-Jose
    Bordelois, Alejandro
    Beuf, Olivier
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2015, 45 (03) : 125 - 133
  • [34] Development of a Proton-Frequency-Transparent Birdcage Radiofrequency Coil for In Vivo 13C MRS/MRSI Study in a 3.0 T MRI System
    Yoon, Jun-Sik
    Kim, Jong-Min
    Chung, Han-Jae
    Jeong, You-Jin
    Jeong, Gwang-Woo
    Park, Ilwoo
    Kim, Gwang-Won
    Oh, Chang-Hyun
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [35] Self-Isolated Dual-Mode High-Pass Birdcage RF Coil for Proton and Sodium MR Imaging at 7 T MRI
    Jeong, You-Jin
    Kumar, Suchit
    Park, Seon-Woo
    Song, Youngkyu
    Cho, Jee-Hyun
    Moon, Chan Hong
    Oh, Chang-Hyun
    APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [36] Design and Performance of a Transformer-Coupled Double Resonant Quadrature Birdcage Coil for Localized Proton and Phosphorus Spectroscopy in the Human Calf Muscle at 7 T
    Brand, Robert C.
    Webb, Andrew G.
    Beenakker, Jan-Willem M.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2013, 42 (05) : 155 - 164
  • [37] Development of a Double Tuned 2H/31P Whole-Body Birdcage Transmit Coil for 2H and 31P MR Applications From Head to Toe at 7 T
    Gursan, Ayhan
    Kahraman-Agir, Busra
    Gosselink, Mark
    Welting, Dimitri
    Froeling, Martijn
    Hoogduin, Hans
    Wiegers, Evita C.
    Prompers, Jeanine J.
    Klomp, Dennis W. J.
    NMR IN BIOMEDICINE, 2025, 38 (03)
  • [38] A dual-tuned multichannel bilateral RF coil for 1H/23Na breast MRI at 7 T
    Ianniello, Carlotta
    Madelin, Guillaume
    Moy, Linda
    Brown, Ryan
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (04) : 1566 - 1575
  • [39] Current Recycled and Self-Phase Shift to Expand the Length of Radio-Frequency Coils, With Application to Brain and Spine Coil Array at 7T MRI
    Hernandez, Daniel
    Kim, Donghyuk
    Nam, Taewoo
    Jeong, Yonghwa
    Seo, Minyeong
    Lee, Eunwoo
    Kim, Junghwan
    Kim, Kyoung-Nam
    IEEE ACCESS, 2023, 11 : 120438 - 120448
  • [40] Design and Simulation of a Double Tuned RF Coil for 1H and 31P MR imaging at 7T
    Du, F.
    Liu, S.
    Li, N.
    Dou, Y.
    Zhang, X.
    Li, Y.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,