Double-Tuned Birdcage Radio Frequency Coil for 7 T MRI: Optimization, Construction and Workbench Validation

被引:0
|
作者
Retico, Alessandra [1 ]
Maggiorelli, Francesca [1 ,2 ,3 ]
Giovannetti, Giulio [4 ]
Boskamp, Eddy [5 ]
Robb, Fraser [6 ]
Fantasia, Marco [7 ]
Galante, Angelo [7 ,8 ,9 ]
Alecci, Marcello [7 ,8 ,9 ]
Tiberi, Gianluigi [10 ,11 ]
Tosetti, Michela [3 ,12 ]
机构
[1] Natl Inst Nucl Phys INFN, Pisa Div, I-56127 Pisa, Italy
[2] Univ Siena, Dept Phys Sci Earth & Environm DSFTA, I-53100 Siena, Italy
[3] Imago7 Fdn, I-56128 Pisa, Italy
[4] Natl Res Council CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[5] Hyperfine Res Inc, Guilford, CT 06437 USA
[6] GE Healthcare Inc, Aurora, OH 44202 USA
[7] Univ Aquila, Dept Life Hlth & Environm Sci MESVA, I-67100 Laquila, Italy
[8] INFN, Gran Sasso Natl Lab, I-67100 Laquila, Italy
[9] Univ Aquila, CNR, SPIN, Dept Phys & Chem Sci, I-67100 Laquila, Italy
[10] London South Bank Univ, Sch Engn, London SE1 0AA, England
[11] Umbria Bioengn Technol UBT Srl, I-06081 Perugia, Italy
[12] IRCCS Stella Maris Fdn, I-56128 Pisa, Italy
关键词
UHF MRI; 7 T MRI; RF coils; double tuned; sodium imaging; TISSUE SODIUM CONCENTRATION; HUMAN BRAIN; MYOCARDIAL-INFARCTION; NA-23; MRI; QUADRATURE; DESIGN; SPECTROSCOPY; MUSCLE; PERFORMANCE; VIABILITY;
D O I
10.3390/electronics12040901
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The aim of the present study is the optimization, construction, and workbench validation of a double-tuned H-1- Na-23 volume radio frequency (RF) coil suitable for human head imaging at 7 T, based on the birdcage geometry. The birdcage-like design which is considered is the four-ring model, in which two standard birdcage-like structures with the same diameters are nested along the longitudinal axis. Simulations based on Maxwell's equations are performed to evaluate the RF magnetic field homogeneity and the RF coil efficiency varying the coil geometrical parameters. The RF magnetic field homogeneity is evaluated both on the transverse (z = 0) and longitudinal (y = 0) planes without performing the impedance matching procedure, so that the RF coil symmetry is not perturbed by the matching network. The RF coil efficiency is instead dependent on the effective coil input RF power, and it is evaluated after matching the coil, so that the reflected power is minimized, assuming that the stimulation power is totally delivered to the RF coil. Considering the simulation results and the target application, the useful RF coil geometrical parameters are fixed. The four-ring model, which showed the best performances, has been built and tested on a workbench, using a cylindrical phantom filled with a 0.05 M saline solution as load. This provides the first example of a four-ring realization intended H-1- Na-23 for human head imaging at 7 T.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Hilbert Curve-Based Metasurface to Enhance Sensitivity of Radio Frequency Coils for 7-T MRI
    Motovilova, Elizaveta
    Huang, Shao Ying
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2019, 67 (02) : 615 - 625
  • [42] Development of double-layer coupled coil for improving S/N in 7T small-animal MRI
    Kim, Kyoung-Nam
    Seo, Jeung-Hoon
    Han, Sang-Doc
    Heo, Phil
    Im, Geun Ho
    Lee, Jung Hee
    SCANNING, 2015, 37 (05) : 361 - 371
  • [43] 4 T Actively detuneable double-tuned 1H/31P head volume coil and four-channel 31P phased array for human brain spectroscopy
    Avdievich, N. T.
    Hetherington, H. P.
    JOURNAL OF MAGNETIC RESONANCE, 2007, 186 (02) : 341 - 346
  • [44] Design and test of a double-nuclear RF coil for 1H MRI and 13C MRSI at 7 T
    Rutledge, Omar
    Kwak, Tiffany
    Cao, Peng
    Zhang, Xiaoliang
    JOURNAL OF MAGNETIC RESONANCE, 2016, 267 : 15 - 21
  • [45] Optimization of an 8-Channel Loop-Array Coil for a 7 T MRI System with the Guidance of a Co-Simulation Approach
    Xinqiang Yan
    ChuangXin Ma
    Lei Shi
    Yan Zhuo
    Xiaohong Joe Zhou
    Long Wei
    Rong Xue
    Applied Magnetic Resonance, 2014, 45 : 437 - 449
  • [46] Optimization of an 8-Channel Loop-Array Coil for a 7 T MRI System with the Guidance of a Co-Simulation Approach
    Yan, Xinqiang
    Ma, ChuangXin
    Shi, Lei
    Zhuo, Yan
    Zhou, Xiaohong Joe
    Wei, Long
    Xue, Rong
    APPLIED MAGNETIC RESONANCE, 2014, 45 (05) : 437 - 449
  • [47] First In Vivo Potassium-39 (39K) MRI at 9.4 T Using Conventional Copper Radio Frequency Surface Coil Cooled to 77 K
    Elabyad, Ibrahim A.
    Kalayciyan, Raffi
    Shanbhag, Nagesh C.
    Schad, Lothar R.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) : 334 - 345
  • [48] Study on the Effect of Non-Symmetrical Current Distribution Controlled by Capacitor Placement in Radio-Frequency Coils for 7T MRI
    Hernandez, Daniel
    Nam, Taewoo
    Jeong, Yonghwa
    Kim, Donghyuk
    Kim, Kyoung-Nam
    BIOSENSORS-BASEL, 2022, 12 (10):
  • [49] 31P MR Spectroscopic Imaging Combined with 1H MR Spectroscopic Imaging in the Human Prostate Using a Double Tuned Endorectal Coil at 7T
    Luttje, Mariska P.
    Italiaander, Michel G. M.
    de Castro, Catalina S. Arteaga
    van der Kemp, Wybe J. M.
    Luijten, Peter R.
    van Vulpen, Marco
    van der Heide, Uulke A.
    Klomp, Dennis W. J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (06) : 1516 - 1521
  • [50] A Novel 1H/3He Dual-Tuned Transmit Coil at Ultra-low Field MRI Designed by Using Electromagnetic Field and Radio Frequency Circuit Co-Simulation Method
    Dou, Y.
    Li, Y.
    Xu, J.
    Chen, Q.
    Wang, L.
    Zhang, X.
    Li, N.
    Luo, C.
    Du, F.
    2018 IEEE INTERNATIONAL MAGNETIC CONFERENCE (INTERMAG), 2018,