Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation

被引:1
|
作者
Li, Xiao-Yu [1 ,2 ]
Liao, Xuan [1 ]
Lin, Jia [1 ]
Lan, Chang-Jun [3 ]
Tan, Qing-Qing [1 ]
机构
[1] North Sichuan Med Coll, Dept Ophthalmol, Affiliated Hosp, Nanchong, Peoples R China
[2] Nanchong Cent Hosp, Clin Coll 2, Dept Ophthalmol, North Sichuan Med Coll, Nanchong, Peoples R China
[3] Sichuan Eye Hosp, Chengdu, Peoples R China
来源
PLOS ONE | 2023年 / 18卷 / 08期
关键词
PURSUING PERFECTION; ACCURACY;
D O I
10.1371/journal.pone.0289033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeTo investigate the effect of the optional biometric parameters lens thickness (LT) and center corneal thickness (CCT) in the Kane formula on intraocular lens (IOL) power calculation.MethodsA cross-sectional study included consecutive cataract patients who received uncomplicated cataract surgery with IOL implantation from May to September 2022 were enrolled. The ocular biometric parameters were obtained using IOLMaster 700 and then inputted into online Kane formula calculator. The IOL power was calculated for targeting emmetropia and compared between groups: not omitting (NO) group, omitting LT and CCT (OLC) group, omitting LT (OL) group and omitting CCT (OC) group. Further, according to the axial length (AL), anterior chamber depth (ACD), and mean keratometry (K-m), the eyes were divided into three subgroups, respectively.Results1005 eyes of 1005 consecutive patients were included. There was no significant difference in IOL power between NO group and OC group (P = 0.064), and the median absolute difference (MedAD) was 0.05D. The IOL power in NO group showed significant differences from OLC group and OL group respectively (P < 0.001), and both MedAD values were 0.18D. Among AL subgroups, MedAD ranged from 0.06D to 0.35D in short eyes. Among ACD subgroups, the above values ranged from 0.06D to 0.23D in shallow ACD subgroup. Among K-m subgroups, these values ranged from 0.05D to 0.31D in steep K-m subgroup.ConclusionThe optional biometric parameter CCT has no effect on the calculation results of the Kane formula, whereas the parameter LT has a great influence on the Kane formula results for the IOL power calculation in cataract patients with short AL, shallow ACD and steep K-m.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Comparison of two optical biometric devices for intraocular lens calculation
    Uckmann, M. -S.
    Stattin, M.
    Zehetner, C.
    Neururer, S.
    Speicher, L.
    OPHTHALMOLOGE, 2019, 116 (03): : 253 - 260
  • [42] COMPARISON OF INTRAOCULAR LENS CALCULATION RESULTS WITH BARRETT UNIVERSAL II FORMULA VS. KANE FORMULA VS, INTRAOPERATIVE ABERROMETRI WITH ORA® SYSTEM
    Leon Valle, Anne
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [43] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [44] Effect of pupil dilation on biometric measurements and intraocular lens power calculations in schoolchildren
    Wang, Xiaogang
    Dong, Jing
    Tang, Maolong
    Wang, Xiaoliang
    Wang, Haitao
    Zhang, Suhua
    PLOS ONE, 2018, 13 (09):
  • [45] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [46] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [47] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [48] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178
  • [49] Intraocular lens power calculation for microphthalmos
    Inatomi, M
    Ishii, K
    Koide, R
    Kora, Y
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (08): : 1208 - 1212
  • [50] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17