Intraocular lens power calculation for microphthalmos

被引:18
|
作者
Inatomi, M
Ishii, K
Koide, R
Kora, Y
Ozawa, T
机构
[1] Department of Ophthalmology, School of Medicine, Showa University Hospital, Tokyo, 8-5-1 Hatanodi, Shinagawa-ku
来源
关键词
D O I
10.1016/S0886-3350(97)80317-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the refractive results and accuracy of intraocular lens (IOL) power calculation formulas in eyes with microphthalmos. Setting: Department of Ophthalmology, Showa University Hospital, Tokyo, Japan. Methods: The accuracy of IOL power calculated using the SRK, SRK II, S-SRK, SRK/T, Holladay, and Hoffer Q formulas was evaluated in six eyes with axial lengths less than 19.0 mm. Results: Postoperative measurement of refraction showed a tendency toward hypermetropia compared with the refraction predicted by each formula. The best predicted refraction was calculated using the SRK/T formula. The tendency for hyperopic estimation was related to the axial length, particularly in eyes with a shorter axial length. However, there was no relationship between the refractive power of the cornea and the error in the predicted refraction by the SRK/T formula. Two eyes with an IOL power of 30.0 diopters (D) had severe hypermetropia. Conclusion: Theoretical formulas were more accurate than empirical ones in eyes with microphthalmos. The severe hypermetropia in the two eyes with a 30.0 D IOL indicates that such patients require a higher IOL power.
引用
收藏
页码:1208 / 1212
页数:5
相关论文
共 50 条
  • [1] Reliability of intraocular lens power calculation after cataract surgery in patients with relative anterior microphthalmos
    Bartke, TU
    Auffarth, GU
    Uhl, JC
    Völcker, HE
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (02) : 138 - 142
  • [2] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [3] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [4] INTRAOCULAR-LENS POWER CALCULATION
    HOPEROSS, M
    MOONEY, D
    EYE, 1988, 2 : 367 - 369
  • [5] CALCULATION OF INTRAOCULAR-LENS POWER
    SUNDERRAJ, P
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 387 - 388
  • [6] INTRAOCULAR-LENS POWER CALCULATION
    HOLLADAY, JT
    PRAGER, TC
    CHRISTIE, B
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1988, 14 (04): : 453 - 454
  • [7] Intraocular lens power calculation software
    Kuchenbecker, J
    Behrens-Baumann, W
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (05): : 735 - 736
  • [8] Intraocular lens power calculation in children
    Eibschitz-Tsimhoni, Maya
    Archer, Steven M.
    Del Monte, Monte A.
    SURVEY OF OPHTHALMOLOGY, 2007, 52 (05) : 474 - 482
  • [9] Intraocular lens power calculation REPLY
    Jin, Haiying
    Rabsilber, Tanja T.
    Ehmer, Angela
    Borkenstein, Andreas F.
    Limberger, Il-Joo
    Guo, Haike
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2177 - 2178
  • [10] Biometry and intraocular lens power calculation
    Lee, Alexander C.
    Qazi, Mujtaba A.
    Pepose, Jay S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (01) : 13 - 17