Biometry and intraocular lens power calculation

被引:157
|
作者
Lee, Alexander C. [1 ,2 ]
Qazi, Mujtaba A. [1 ,2 ]
Pepose, Jay S. [1 ,2 ]
机构
[1] Washington Univ, Sch Med, Dept Ophthalmol & Visual Sci, St Louis, MO 63017 USA
[2] Washington Univ, Sch Med, Pepose Vis Inst, St Louis, MO 63017 USA
关键词
biometry; cataract surgery; intraocular lens calculation;
D O I
10.1097/ICU.0b013e3282f1c5ad
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review Heightened patient expectations for precise postoperative refractive results have spurred the continued improvements in biometry and intraocular lens calculations. In order to meet these expectations, attention to proper patient selection, accurate keratometry and biometry, and appropriate intraocular lens power formula selection with optimized lens constants are required. The article reviews recent studies and advances in the field of biometry and intraocular lens power calculations. Recent findings Several noncontact optical-based devices compare favorably, if not superiorly, to older ultrasonic biometric and keratometric techniques. With additional improvements in the internal acquisition algorithm, the new IOL Master software version 5 upgrade should lessen operator variability and further enhance signal acquisition. The modern Haigis-L and Holladay 2 formulas more accurately determine the position and the shape of the intraocular lens power prediction curve. Summary Postoperative refractive results depend on the precision of multiple factors and measurements. The element with the highest variability and inaccuracy is, ultimately, going to determine the outcome. By understanding the advantages and limitations of the current technology, it is possible to consistently achieve highly accurate results.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [1] Update on biometry and intraocular lens power calculation
    Hirnschall, Nino
    Findl, Oliver
    SPEKTRUM DER AUGENHEILKUNDE, 2020, 34 (5-6) : 137 - 143
  • [2] Biometry and intraocular lens power calculation for cataract surgery: an update
    Findl, O.
    SPEKTRUM DER AUGENHEILKUNDE, 2007, 21 (02) : 90 - 93
  • [3] Understanding intraocular lens calculation and biometry
    Barrett, Graham D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (12): : 1499 - 1501
  • [4] Intraocular lens power calculation for humanitarian missions based on partial biometry
    Schmitz, Joseph W.
    Davis, Kimberly D.
    IVcClatchey, Scott K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1187 - 1191
  • [5] Update Biometrie und KunstlinsenberechnungUpdate on biometry and intraocular lens power calculation
    Nino Hirnschall
    Oliver Findl
    Spektrum der Augenheilkunde, 2020, 34 : 137 - 143
  • [6] BIOMETRY AND INTRAOCULAR LENS CALCULATION IN EXTREME MYOPIA
    Haigis, Wolfgang
    ACTA CLINICA CROATICA, 2012, 51 : 65 - 69
  • [7] Intraoperative biometry for intraocular lens (IOL) power calculation at silicone oil removal
    El-Baha, SM
    El-Samadoni, A
    Idris, HF
    Rashad, KM
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2003, 13 (07) : 622 - 626
  • [8] Immersion Biometry for Intraocular Lens Power Calculation with Fourth-Generation Formulas
    Skrzypecki, Janusz
    Grabska-Liberek, Iwona
    Guszkowska, Maria
    Izdebska, Justyna
    Szaflik, Jacek P.
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2159 - 2162
  • [9] Biometry, keratometry, and calculation of intraocular lens power for the bald eagle (Haliaeetus leucocephalus)
    Kuhn, Sonia E.
    Hendrix, Diane V. H.
    Jones, Michael P.
    Ward, Daniel A.
    Baine, Katherine H.
    Franklin, Stephen R.
    VETERINARY OPHTHALMOLOGY, 2015, 18 : 106 - 112
  • [10] Accuracy of biometry using automated and manual keratometry for intraocular lens power calculation
    Khan, Lubna
    Sharma, Babita
    Gupta, Harshal
    Rana, Rimpi
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2018, 8 (02) : 93 - 98