摘要
PurposeTo investigate the effect of the optional biometric parameters lens thickness (LT) and center corneal thickness (CCT) in the Kane formula on intraocular lens (IOL) power calculation.MethodsA cross-sectional study included consecutive cataract patients who received uncomplicated cataract surgery with IOL implantation from May to September 2022 were enrolled. The ocular biometric parameters were obtained using IOLMaster 700 and then inputted into online Kane formula calculator. The IOL power was calculated for targeting emmetropia and compared between groups: not omitting (NO) group, omitting LT and CCT (OLC) group, omitting LT (OL) group and omitting CCT (OC) group. Further, according to the axial length (AL), anterior chamber depth (ACD), and mean keratometry (K-m), the eyes were divided into three subgroups, respectively.Results1005 eyes of 1005 consecutive patients were included. There was no significant difference in IOL power between NO group and OC group (P = 0.064), and the median absolute difference (MedAD) was 0.05D. The IOL power in NO group showed significant differences from OLC group and OL group respectively (P < 0.001), and both MedAD values were 0.18D. Among AL subgroups, MedAD ranged from 0.06D to 0.35D in short eyes. Among ACD subgroups, the above values ranged from 0.06D to 0.23D in shallow ACD subgroup. Among K-m subgroups, these values ranged from 0.05D to 0.31D in steep K-m subgroup.ConclusionThe optional biometric parameter CCT has no effect on the calculation results of the Kane formula, whereas the parameter LT has a great influence on the Kane formula results for the IOL power calculation in cataract patients with short AL, shallow ACD and steep K-m.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] The Effect of Testing Distance on Intraocular Lens Power Calculation
    Simpson, Michael J.
    Charman, W. Neil
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 726 - 726
  • [32] Effect of anterior chamber depth on the choice of intraocular lens calculation formula
    Yang, Soonwon
    Whang, Woong-Joo
    Joo, Choun-Ki
    PLOS ONE, 2017, 12 (12):
  • [33] Accuracy of a universal theoretical formula for power calculation in pediatric intraocular lens implantation
    Eppley, Sarah E.
    Arnold, Benjamin F.
    Tadros, Dina
    Pasricha, Neel
    Campomanes, Alejandra G. de Alba
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (05): : 599 - 605
  • [34] FACTORS INFLUENCING THE ACCURACY OF THE SRK FORMULA IN THE INTRAOCULAR-LENS POWER CALCULATION
    KALOGEROPOULOS, C
    ASPIOTIS, M
    STEFANIOTOU, M
    PSILAS, K
    DOCUMENTA OPHTHALMOLOGICA, 1994, 85 (03) : 223 - 242
  • [35] A new formula for intraocular lens power calculation after refractive corneal surgery
    Camellin, M
    Calossi, A
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) : 187 - 199
  • [36] Performance of a simplified strategy for formula constant optimisation in intraocular lens power calculation
    Langenbucher, Achim
    Wendelstein, Jascha
    Szentmary, Nora
    Cayless, Alan
    Hoffmann, Peter
    Debellmaniere, Guillaume
    Gatinel, Damien
    ACTA OPHTHALMOLOGICA, 2025, 103 (01) : e10 - e18
  • [37] DEVELOPMENT OF THE SRK/T INTRAOCULAR-LENS IMPLANT POWER CALCULATION FORMULA
    RETZLAFF, JA
    SANDERS, DR
    KRAFF, MC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (03): : 333 - 340
  • [38] Intraocular lens power calculation for lens exchange
    Kora, Y
    Shimizu, K
    Yoshida, M
    Inatomi, M
    Ozawa, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (04): : 543 - 548
  • [39] Intraocular Lens Power Calculation Without Corneal Parameters: A New Option
    Rosa, Nicola
    Zeppa, Lucio
    De Bernardo, Maddalena
    Coppola, Alessia
    Zeppa, Lucia
    Borrelli, Maria
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2021, 47 (04): : 208 - 212
  • [40] Intraocular lens power calculation formula in congenital cataracts: Are we using the correct formula for pediatric eyes?
    Kaur, Savleen
    Sukhija, Jaspreet
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (12) : 3442 - 3445