Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation

被引:1
|
作者
Li, Xiao-Yu [1 ,2 ]
Liao, Xuan [1 ]
Lin, Jia [1 ]
Lan, Chang-Jun [3 ]
Tan, Qing-Qing [1 ]
机构
[1] North Sichuan Med Coll, Dept Ophthalmol, Affiliated Hosp, Nanchong, Peoples R China
[2] Nanchong Cent Hosp, Clin Coll 2, Dept Ophthalmol, North Sichuan Med Coll, Nanchong, Peoples R China
[3] Sichuan Eye Hosp, Chengdu, Peoples R China
来源
PLOS ONE | 2023年 / 18卷 / 08期
关键词
PURSUING PERFECTION; ACCURACY;
D O I
10.1371/journal.pone.0289033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
PurposeTo investigate the effect of the optional biometric parameters lens thickness (LT) and center corneal thickness (CCT) in the Kane formula on intraocular lens (IOL) power calculation.MethodsA cross-sectional study included consecutive cataract patients who received uncomplicated cataract surgery with IOL implantation from May to September 2022 were enrolled. The ocular biometric parameters were obtained using IOLMaster 700 and then inputted into online Kane formula calculator. The IOL power was calculated for targeting emmetropia and compared between groups: not omitting (NO) group, omitting LT and CCT (OLC) group, omitting LT (OL) group and omitting CCT (OC) group. Further, according to the axial length (AL), anterior chamber depth (ACD), and mean keratometry (K-m), the eyes were divided into three subgroups, respectively.Results1005 eyes of 1005 consecutive patients were included. There was no significant difference in IOL power between NO group and OC group (P = 0.064), and the median absolute difference (MedAD) was 0.05D. The IOL power in NO group showed significant differences from OLC group and OL group respectively (P < 0.001), and both MedAD values were 0.18D. Among AL subgroups, MedAD ranged from 0.06D to 0.35D in short eyes. Among ACD subgroups, the above values ranged from 0.06D to 0.23D in shallow ACD subgroup. Among K-m subgroups, these values ranged from 0.05D to 0.31D in steep K-m subgroup.ConclusionThe optional biometric parameter CCT has no effect on the calculation results of the Kane formula, whereas the parameter LT has a great influence on the Kane formula results for the IOL power calculation in cataract patients with short AL, shallow ACD and steep K-m.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] SRK-II FORMULA IN THE CALCULATION OF INTRAOCULAR-LENS POWER
    DANG, MS
    RAJ, PPS
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1989, 73 (10) : 823 - 826
  • [22] Preliminary demonstration of a novel intraocular lens power calculation: the O formula
    Goto, So
    Maeda, Naoyuki
    Ohnuma, Kazuhiko
    Lawu, Tjundewo
    Kawasaki, Ryo
    Koh, Shizuka
    Nishida, Kohji
    Noda, Toru
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (11): : 1305 - 1311
  • [23] Biometric calculation of intraocular lens power for cataract surgery following pupil dilatation
    Bansal, Shveta
    Quah, Say A.
    Turpin, Tim
    Batterbury, Mark
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 36 (02): : 156 - 158
  • [24] Impact of uncertainties in biometric parameters on intraocular lens power formula predicted refraction using a Monte-Carlo simulation
    Langenbucher, Achim
    Hoffmann, Peter
    Cayless, Alan
    Bolz, Matthias
    Wendelstein, Jascha
    Szentmary, Nora
    ACTA OPHTHALMOLOGICA, 2024, 102 (03) : e285 - e295
  • [25] Effect of Intraocular Lens Power Calculation Formula Optimization in the Sum-of-Segments Optical Biometer
    Kojima, Takashi
    Tamaoki, Akeno
    Ichikawa, Kazuo
    Satoh, Yuya
    Tomemori, Ryota
    Watanabe, Keizo
    Hasegawa, Asato
    Sawaki, Ayako
    Kaga, Tatsushi
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 2545 - 2553
  • [26] Comparison of newer Kane formula with Sanders Retzlaff Kraff/Theoretical and Barrett Universal II for calculation of intraocular lens power in Indian eyes
    Paritekar, Prajakta
    Nayak, Akshay
    Umesh, Y.
    Sirivella, Indrani
    Manoharan, Sharanya
    Khatib, Zain
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1203 - 1207
  • [27] Evaluation of three biometric devices: ocular parameters and calculated intraocular lens power
    Rivkah Lender
    Devora Mirsky
    Riki Greenberger
    Zipora Boim
    Lee Ben-Yaakov
    Chaya Kashtan
    Ibrahim Naffar
    Shira Shine
    Itay Chowers
    Hadas Ben-Eli
    Scientific Reports, 12
  • [28] Evaluation of three biometric devices: ocular parameters and calculated intraocular lens power
    Lender, Rivkah
    Mirsky, Devora
    Greenberger, Riki
    Boim, Zipora
    Ben-Yaakov, Lee
    Kashtan, Chaya
    Naffar, Ibrahim
    Shine, Shira
    Chowers, Itay
    Ben-Eli, Hadas
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [29] Intraocular lens power calculation
    Olsen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (12): : 2176 - 2177
  • [30] Pterygium size and effect on intraocular lens power calculation
    Koc, Mustafa
    Uzel, Mehmet Murat
    Aydemir, Emre
    Yavrum, Fuat
    Kosekahya, Pinar
    Yilmazbas, Pelin
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (11): : 1620 - 1625