Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit

被引:2
|
作者
Boudjella, Manal Yasmine [1 ]
Belbachir, Ahmed Hafid [1 ]
Dib, Samy Anis Amine [1 ]
Meftah, Mustapha [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Versailles St Quentin En Yvelines, Sorbonne Univ, Univ Paris Saclay, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Solar spectral irradiance; Atmospheric transmittance; Radiative transfer models; Geant4; MYSTIC; Beer-Lambert law; RADIATIVE-TRANSFER; SOLAR IRRADIANCE; MULTIPLE-SCATTERING; MODELS; SIMULATION; RETRIEVAL; DATABASE; VERSION; CODE;
D O I
10.1016/j.jastp.2023.106077
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The spectral direct normal irradiance (DNI) of the surface spectral irradiance, with a spectral resolution of 1 nm in the range of 280-1600 nm, and 5 nm in the range of 1600-3000 nm, has been calculated for the first time with the Geant4 Monte Carlo simulation toolkit using the US Standard Atmosphere 1976 model and the reference extraterrestrial solar spectrum SOLAR-ISS. The atmospheric attenuation of DNI has been studied with and without aerosols. In the presence of aerosols corresponding to 10 km visibility, the total solar DNI attenuation can reach about 84% in the UV domain, 56% in the visible domain and 35.08% in the rest of the infrared domain. The Geant4 results have been compared to those calculated by the MYSTIC code of LibRadtran package and the Beer-Lambert law under the same atmospheric conditions. The average relative transmittance difference between Geant4 and MYSTIC is of the order of few percent in the entire solar spectrum. In the case of atmosphere with aerosols corresponding to 23 km visibility, the most important average of the relative difference between Geant4 and MYSTIC transmittances is about 7.5% in the UV domain and stays between 1.19% and, 3.31% in the rest of the spectrum. More importantly, in this last case of the atmosphere, the values of the spectral transmittance of Geant4 remain intermediate between those of MYSTIC and Beer-Lambert law in the entire visible range up to 800 nm.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Implementation of the reverse/adjoint Monte Carlo method into Geant4
    Desorgher, L.
    Lei, F.
    Santin, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 621 (1-3): : 247 - 257
  • [42] Dynamic Monte Carlo Dose Calculations for IMRT in Geant4
    Hancox, C.
    Seco, J.
    Sharp, G.
    Peroni, M.
    Paganetti, H.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [43] Evaluation of a commercial MRI Linac based Monte Carlo dose calculation algorithm with GEANT4
    Ahmad, Syed Bilal
    Sarfehnia, Arman
    Paudel, Moti Raj
    Kim, Anthony
    Hissoiny, Sami
    Sahgal, Arjun
    Keller, Brian
    [J]. MEDICAL PHYSICS, 2016, 43 (02) : 894 - 907
  • [44] Development of a complete simulation package for Self-Powered Neutron Detectors using the Monte Carlo Method and Geant4 toolkit
    Li, Kun
    Li, Gang
    Wan, Bo
    Yang, Daibo
    Li, Dan
    Weng, Xiaohui
    Li, Ang
    Yin, Qiusheng
    Wang, Haibo
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (08)
  • [45] Monte Carlo simulations of the n_TOF lead spallation target with the Geant4 toolkit: A benchmark study
    Lerendegui-Marco, J.
    Cortes-Giraldo, M. A.
    Guerrero, C.
    Quesada, J. M.
    Lo Meo, S.
    Massimi, C.
    Barbagallo, M.
    Colonna, N.
    Mancussi, D.
    Mingrone, F.
    Sabate-Gilarte, M.
    Vannini, G.
    Vlachoudis, V.
    Aberle, O.
    Andrzejewski, J.
    Audouin, L.
    Bacak, M.
    Balibrea, J.
    Becvar, F.
    Berthoumieux, E.
    Billowes, J.
    Bosnar, D.
    Brown, A.
    Caamano, M.
    Calvino, F.
    Calviani, M.
    Cano-Ott, D.
    Cardella, R.
    Casanovas, A.
    Cerutti, F.
    Chen, Y. H.
    Chiaveri, E.
    Cortes, G.
    Cosentino, L.
    Damone, L. A.
    Diakaki, M.
    Domingo-Pardo, C.
    Dressler, R.
    Dupont, E.
    Duran, I.
    Fernandez-Dominguez, B.
    Ferrari, A.
    Ferreira, P.
    Finocchiaro, P.
    Goebel, K.
    Gomez-Hornillos, M. B.
    Garcia, A. R.
    Gawlik, A.
    Gilardoni, S.
    Glodariu, T.
    [J]. ND 2016: INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, 2017, 146
  • [46] Implementation of the n-body Monte-Carlo event generator into the Geant4 toolkit for photonuclear studie
    Luo, Wen
    Lan, Hao-yang
    Xu, Yi
    Balabanski, Dirniter L.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 849 : 49 - 54
  • [47] Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector
    Joel, Guembou Shouop Cebastien
    Maurice, Ndontchueng Moyo
    Jilbert, Nguelem Mekongtso Eric
    Ousmanou, Motapon
    David, Strivay
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2018, 189 : 109 - 119
  • [48] Medical applications of the Geant4 toolkit
    Agostinelli, S
    Chauvie, S
    Foppiano, F
    Garelli, S
    Marchetto, F
    Pia, MG
    Nieminen, P
    Rolando, V
    Solano, A
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 543 - 548
  • [49] Calculation of absorbed dose factors for Re-186 in radiation synovectomy using Monte Carlo simulation with Geant4
    Lagares, L. C.
    Veloza, L. S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1842 - 1845
  • [50] Introduction to the Geant4 Simulation toolkit
    Guatelli, S.
    Cutajar, D.
    Oborn, B.
    Rosenfeld, A. B.
    [J]. CONCEPTS AND TRENDS IN MEDICAL RADIATION DOSIMETRY, 2011, 1345 : 303 - 322