Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit

被引:3
|
作者
Boudjella, Manal Yasmine [1 ]
Belbachir, Ahmed Hafid [1 ]
Dib, Samy Anis Amine [1 ]
Meftah, Mustapha [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Versailles St Quentin En Yvelines, Sorbonne Univ, Univ Paris Saclay, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Solar spectral irradiance; Atmospheric transmittance; Radiative transfer models; Geant4; MYSTIC; Beer-Lambert law; RADIATIVE-TRANSFER; SOLAR IRRADIANCE; MULTIPLE-SCATTERING; MODELS; SIMULATION; RETRIEVAL; DATABASE; VERSION; CODE;
D O I
10.1016/j.jastp.2023.106077
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The spectral direct normal irradiance (DNI) of the surface spectral irradiance, with a spectral resolution of 1 nm in the range of 280-1600 nm, and 5 nm in the range of 1600-3000 nm, has been calculated for the first time with the Geant4 Monte Carlo simulation toolkit using the US Standard Atmosphere 1976 model and the reference extraterrestrial solar spectrum SOLAR-ISS. The atmospheric attenuation of DNI has been studied with and without aerosols. In the presence of aerosols corresponding to 10 km visibility, the total solar DNI attenuation can reach about 84% in the UV domain, 56% in the visible domain and 35.08% in the rest of the infrared domain. The Geant4 results have been compared to those calculated by the MYSTIC code of LibRadtran package and the Beer-Lambert law under the same atmospheric conditions. The average relative transmittance difference between Geant4 and MYSTIC is of the order of few percent in the entire solar spectrum. In the case of atmosphere with aerosols corresponding to 23 km visibility, the most important average of the relative difference between Geant4 and MYSTIC transmittances is about 7.5% in the UV domain and stays between 1.19% and, 3.31% in the rest of the spectrum. More importantly, in this last case of the atmosphere, the values of the spectral transmittance of Geant4 remain intermediate between those of MYSTIC and Beer-Lambert law in the entire visible range up to 800 nm.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics
    Carrier, JF
    Archambault, L
    Beaulieu, L
    Roy, R
    MEDICAL PHYSICS, 2004, 31 (03) : 484 - 492
  • [22] The Geant4 Simulation Toolkit and Applications For the Geant4 Collaboration
    Apostolakis, John
    MOLECULAR IMAGING: COMPUTER RECONSTRUCTION AND PRACTICE, 2008, : 73 - 92
  • [23] Monte Carlo calculation of beam quality correction factors in proton beams using TOPAS/GEANT4
    Baumann, Kilian-Simon
    Kaupa, Sina
    Bach, Constantin
    Engenhart-Cabillic, Rita
    Zink, Klemens
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (05):
  • [24] Geant4 Monte Carlo simulations for the LPCTrap setup
    Rodriguez, D.
    Ban, G.
    Durand, D.
    Duval, F.
    Flechard, X.
    Lienard, E.
    Mauger, F.
    Mery, A.
    Naviliat-Cuncic, O.
    Thomas, J. -C.
    Velten, Ph.
    EUROPEAN PHYSICAL JOURNAL A, 2009, 42 (03): : 397 - 400
  • [25] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Chen, Jun-Liang
    Yun, Su-Jun
    Dong, Tie-Kuang
    Ren, Zhong-Zhou
    Zhang, Xiao-Ping
    NUCLEAR SCIENCE AND TECHNIQUES, 2022, 33 (01)
  • [26] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Jun-Liang Chen
    Su-Jun Yun
    Tie-Kuang Dong
    Zhong-Zhou Ren
    Xiao-Ping Zhang
    Nuclear Science and Techniques, 2022, 33
  • [27] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [28] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [29] Studies of the radiation environment on the Mars surface using the Geant4 toolkit
    Jun-Liang Chen
    Su-Jun Yun
    Tie-Kuang Dong
    Zhong-Zhou Ren
    Xiao-Ping Zhang
    NuclearScienceandTechniques, 2022, 33 (01) : 122 - 132
  • [30] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400