Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit

被引:2
|
作者
Boudjella, Manal Yasmine [1 ]
Belbachir, Ahmed Hafid [1 ]
Dib, Samy Anis Amine [1 ]
Meftah, Mustapha [2 ]
机构
[1] Univ Sci & Technol Oran Mohamed Boudiaf USTO MB, Fac Phys, Lab Anal & Applicat Radiat LAAR, BP 1505, Oran 31000, Algeria
[2] Univ Versailles St Quentin En Yvelines, Sorbonne Univ, Univ Paris Saclay, Lab Atmospheres Milieux Observat Spatiales LATMOS,, 11 Blvd Alembert, F-78280 Guyancourt, France
关键词
Solar spectral irradiance; Atmospheric transmittance; Radiative transfer models; Geant4; MYSTIC; Beer-Lambert law; RADIATIVE-TRANSFER; SOLAR IRRADIANCE; MULTIPLE-SCATTERING; MODELS; SIMULATION; RETRIEVAL; DATABASE; VERSION; CODE;
D O I
10.1016/j.jastp.2023.106077
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The spectral direct normal irradiance (DNI) of the surface spectral irradiance, with a spectral resolution of 1 nm in the range of 280-1600 nm, and 5 nm in the range of 1600-3000 nm, has been calculated for the first time with the Geant4 Monte Carlo simulation toolkit using the US Standard Atmosphere 1976 model and the reference extraterrestrial solar spectrum SOLAR-ISS. The atmospheric attenuation of DNI has been studied with and without aerosols. In the presence of aerosols corresponding to 10 km visibility, the total solar DNI attenuation can reach about 84% in the UV domain, 56% in the visible domain and 35.08% in the rest of the infrared domain. The Geant4 results have been compared to those calculated by the MYSTIC code of LibRadtran package and the Beer-Lambert law under the same atmospheric conditions. The average relative transmittance difference between Geant4 and MYSTIC is of the order of few percent in the entire solar spectrum. In the case of atmosphere with aerosols corresponding to 23 km visibility, the most important average of the relative difference between Geant4 and MYSTIC transmittances is about 7.5% in the UV domain and stays between 1.19% and, 3.31% in the rest of the spectrum. More importantly, in this last case of the atmosphere, the values of the spectral transmittance of Geant4 remain intermediate between those of MYSTIC and Beer-Lambert law in the entire visible range up to 800 nm.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [32] Optimization of an ultra-fast silicon detector for proton and carbon beams using GEANT4 Monte Carlo toolkit
    Mashayekhi, Mohsen
    Mowlavi, Ali Asghar
    Jia, Sayyed Bijan
    Ghayoumizadeh, Hossein
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 109 - 112
  • [33] Using Geant4 Monte Carlo toolkit to evaluate a low power X-ray tube generator configuration
    Hoff, G.
    Streck, E. E.
    Lai, A.
    Fanti, V
    Golosio, B.
    Nascimento, C. D.
    Souza, E. G.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 168
  • [34] An overview of the Geant4 toolkit
    Apostolakis, John
    Wright, Dennis H.
    [J]. HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 1 - +
  • [35] Implementation of detector response function modeling for small animal SPECT using Geant4 Monte Carlo Simulation Toolkit
    El Bitar, Ziad
    Brasse, David
    Gullberg, Grant
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [36] Proton Therapy Range Verification Using Prompt Gamma Rays: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [37] Dosimetric Validation of An Intrabeam™ GATE Model, Based On Monte Carlo GEANT4 Toolkit, for IORT Applications
    Bouzid, D.
    Visvikis, D.
    Dupre, P.
    Bert, J.
    Pradier, O.
    Nicolas, B.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [38] Combination of electromagnetic physics processes for microdosimetry in liquid water with the Geant4 Monte Carlo simulation toolkit
    Ivanchenko, V. N.
    Incerti, S.
    Francis, Z.
    Tran, H. N.
    Karamitros, M.
    Bernal, M. A.
    Champion, C.
    Gueye, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 273 : 95 - 97
  • [39] Monte Carlo simulation of the Zeiss INTRABEAM with cylinder applicator using the GEANT4 precise dose calculation in the IORT
    Clausen, S.
    Schneider, F.
    Jahnke, L.
    Fleckenstein, J.
    Hesser, J.
    Wenz, F.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 51 - 51
  • [40] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757