Monte Carlo method for gamma spectrometry based on GEANT4 toolkit: Efficiency calibration of BE6530 detector

被引:33
|
作者
Joel, Guembou Shouop Cebastien [1 ,2 ,3 ]
Maurice, Ndontchueng Moyo [3 ,4 ]
Jilbert, Nguelem Mekongtso Eric [2 ,3 ]
Ousmanou, Motapon [4 ]
David, Strivay [1 ]
机构
[1] Univ Liege, Archeometry, Atom & Nucl Spect, Bat B15 Sart Tilman, B-4000 Liege 1, Belgium
[2] Univ Douala, Fundamental Phys Lab Math Appl Comp Sci & Fundame, POB 24157, Douala, Cameroon
[3] Natl Radiat Protect Agcy, POB 33732, Yaounde, Cameroon
[4] Univ Douala, Dept Phys, Fac Sci, POB 24157, Douala, Cameroon
关键词
Monte Carlo method; GEANT4; toolkit; Gamma spectrometry; Simulation; Efficiency; BE6530; COMPTON SUPPRESSION SYSTEM; ENERGY HPGE DETECTOR; ENVIRONMENTAL-SAMPLES; GERMANIUM DETECTOR; RAY SPECTROMETRY; SIMULATION; COINCIDENCE; OPTIMIZATION; PEAK; CODE;
D O I
10.1016/j.jenvrad.2018.03.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The combination of gamma-ray spectrometry, the development of related Monte Carlo method and the GEANT4 (GEometry ANd Tracking) toolkit have been developed for gamma spectrometry simulation. The main objective was to validate simulation models of broad energy germanium (BEGe) detector geometry built in our laboratory (BE6530 model). Monte Carlo simulation of the geometry of BE6530 detector for efficiency calibration was carried out with GEANT4 toolkit. The simulated efficiencies curves using MC were compared with experimental results. Measurement uncertainties for both simulation and experimental estimations of the efficiency were assessed in order to see whether the consequences of the realistic measurement fall inside adequate cut-off points. The validation of the simulation was carried out by experimentally estimating the activity concentration in a reference sample and the comparison showed good correlation between experimental and simulation. Therefore, from the outcomes of this study, it can be concluded that Monte-Carlo simulation is a helpful, reasonable option that additionally gives more prominent adaptability, greater flexibility, precision and accuracy, and gained time when determining the detector response and efficiency in routine of environmental radioactivity monitoring.
引用
收藏
页码:109 / 119
页数:11
相关论文
共 50 条
  • [1] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    [J]. NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [2] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Weihua Zhang
    Pawel Mekarski
    Jonathan Lam
    Kurt Ungar
    Eric Pellerin
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2010, 285 : 475 - 482
  • [3] Geant4 Monte Carlo radioxenon beta-gamma coincidence efficiency simulation for a phoswich detector
    Zhang, Weihua
    Mekarski, Pawel
    Lam, Jonathan
    Ungar, Kurt
    Pellerin, Eric
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 285 (03) : 475 - 482
  • [4] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit
    Freudenberg, Robert
    Kotzerke, Jorg
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09): : 1488 - 1489
  • [5] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09): : 1489 - 1489
  • [6] GEANT4 CALIBRATION OF GAMMA SPECTROMETRY EFFICIENCY FOR MEASUREMENTS OF AIRBORNE RADIOACTIVITY ON FILTER PAPER
    Alrefae, Tareq
    [J]. HEALTH PHYSICS, 2014, 107 (05): : 435 - 441
  • [7] Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit
    Incerti, S.
    Zhang, Q.
    Andersson, F.
    Moretto, Ph.
    Grime, G. W.
    Merchant, M. J.
    Nguyen, D. T.
    Habchi, C.
    Pouthier, T.
    Seznec, H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 20 - 27
  • [8] Polarized electron Mott scattering model for the Geant4 Monte Carlo toolkit
    Dragowski, M.
    Adamus, M.
    Weber, G.
    Wlodarczyk, M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2021, 488 : 37 - 42
  • [9] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    S. Penabeï
    D. Bongue
    A. B. Mistura
    P. Maleka
    K. M. Demdah
    G. N. M. Kwato
    [J]. International Journal of Environmental Science and Technology, 2024, 21 : 4509 - 4518
  • [10] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    Penabei, S.
    Bongue, D.
    Mistura, A. B.
    Maleka, P.
    Demdah, K. M.
    Kwato, G. N. M.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024, 21 (04) : 4509 - 4518