Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens

被引:0
|
作者
Kenia, Vaishal P. [1 ]
Kenia, Raj V. [2 ]
Mudaliya, Laxmi [3 ]
Pirdankar, Onkar H. [4 ,5 ]
机构
[1] Kenia Eye Hosp, Dept Cataract & Refract Surg, Mumbai, Maharashtra, India
[2] Kenia Fdn, Dept Ophthalmol, Mumbai, Maharashtra, India
[3] Kenia Med & Res Fdn, Dept Clin Res, Mumbai, Maharashtra, India
[4] Kenia Med & Res Fdn, Dept Clin Res, Mumbai 400054, Maharashtra, India
[5] Kenia Med & Res Fdn, Mumbai 400054, Maharashtra, India
关键词
Extended Depth of Focus IOL; higher order aberrations; visual outcomes; OPTICAL-PERFORMANCE; QUALITY;
D O I
10.4103/tjo.tjo_16_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes. MATERIALS AND METHODS: This is retrospective case series where subjects aged between 40-65 years and were implanted with LUCIDIS IOL by single surgeon were included. Subjects with Pre surgery corneal astigmatism > 1.50 D, corneal guttae, IOP >22mmHg, any ocular Co morbidities, Intra or post operative complication were excluded. At 1 month follow up, uncorrected visual acuities at distance (UCDVA), intermediate (UCIVA) and near (UCNVA), refraction were recorded. Internal Higher order aberrations and strehl ratio for a fixed pupil of 4mm and 6mm were calculated using NIDEK OPD Scan. Monocular defocus curve was obtained at 4 meter logMAR chart.RESULTS: Total of 55 eyes of 35 patients with mean +/- SD age of 58.50 +/- 7.49 years were evaluated. 89.09% of the eyes achieved visual acuity of 6/6. 49.09% could read N10 font at intermediate distance without any correction and 85.45% of the eyes had uncorrected near visual acuity of N6. Around 67% of the eyes did not require any refractive correction whereas around 26% of the eyes required correction upto +/- 0.25D. The defocus curve showed that visual acuity also ranges from 0.05 logMAR to 0.2 logMAR for Plano to -3.00D respectively. Mean +/- SD Strehl ratio at 4 and 6 mm pupil size was 0.06 +/- 0.04 and 0.02 +/- 0.02 respectively.CONCLUSION: Hybrid EDOF IOL such as LUCIDIS provides excellent vision at all distances. This could be attributed to IOL design which is spherical aberration neutral lens.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 50 条
  • [11] Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses
    Baur, Isabella D.
    Yan, Weijia
    Auffarth, Gerd U.
    Khoramnia, Ramin
    Labuz, Grzegorz
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (10) : 668 - 675
  • [12] Visual outcomes of binocular implantation of a new extended depth of focus intraocular lens
    Sinha, Rajesh
    Sahay, Pranita
    Saxena, Rohit
    Kalra, Nidhi
    Gupta, Vinay
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (10) : 2111 - 2116
  • [13] Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens
    Crema, Armando S.
    Walsh, Aileen
    Ventura, Bruna V.
    Santhiago, Marcony R.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (07) : 486 - 491
  • [14] Real-world visual outcomes of a non-diffractive extended depth of focus intraocular lens implanted in Australian sites
    Mangat, Simran
    Sabel, Robyn
    Rose, Monique
    Perez-Vives, Caridad
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 51 (09): : 1015 - 1016
  • [15] Analysis of internal astigmatism and higher order aberrations in eyes implanted with a new diffractive multifocal toric intraocular lens
    Peter Mojzis
    David P. Piñero
    Vera Ctvrteckova
    Iva Rydlova
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 341 - 348
  • [16] Analysis of internal astigmatism and higher order aberrations in eyes implanted with a new diffractive multifocal toric intraocular lens
    Mojzis, Peter
    Pinero, David P.
    Ctvrteckova, Vera
    Rydlova, Iva
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 341 - 348
  • [17] Clinical Outcomes of a Refractive Extended Depth of Focus Intraocular Lens
    Orbegozo, Javier
    Perez, Angelica
    Basterra, Inaki
    Noguera, Helena
    Diaz, Sergio
    Gonzalez, Laura
    Lauzirika, Gorka
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (03) : e238 - e247
  • [18] Expanding depth of focus by modifying higher-order aberrations induced by an adaptive optics visual simulator
    Rocha, Karolinne Maia
    Vabre, Laurent
    Chateau, Nicolas
    Krueger, Ronald R.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (11): : 1885 - 1892
  • [19] Visual outcomes and photic phenomena following bilateral extended depth of focus intraocular lens implants
    Sundaram, Aishwarya
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2020, 55 (02): : E50 - E51
  • [20] Refractive and Visual Outcomes After Implantation of a Secondary Sulcus Intraocular Lens with an Extended Depth of Focus
    Gundersen, Kjell Gunnar
    Potvin, Richard
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1861 - 1869