Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses

被引:7
|
作者
Baur, Isabella D. [1 ]
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ,2 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Heidelberg Univ, David J Apple Ctr Vis Res, Dept Ophthalmol, Heidelberg, Germany
[2] Heidelberg Univ, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
D O I
10.3928/1081597X-20230831-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc).METHODS: An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps. Area under the MTF and simulated visual acuity were calculated for different pupil diameters. Wavefront aberrations were measured with the SHS Ophthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor.RESULTS: All EDOF lenses yielded a simulated far visual acuity of 0.00 logMAR (20/20 Snellen) or better. At the 0.20 logMAR visual acuity level, the EDOF IOLs showed an increased depth of focus of at least 0.75 diopters compared to the monofocal IOL. Pupil dependency was more pronounced with the MiniWell, LuxSmart, and Vivity, whereas the Lentis showed a more consistent behavior at different apertures. The wavefront measurement revealed increased central aberrations for the MiniWell, LuxSmart, and Vivity IOL compared to the monofocal control.CONCLUSIONS: All EDOF IOLs demonstrated increased depth of focus while maintaining good simulated visual acuity at the far focus. Pupil dependency differed between the IOL models. The wavefront analysis revealed the complex design of the different EDOF IOLs with several zones with varying aberrations.
引用
收藏
页码:668 / 675
页数:8
相关论文
共 50 条
  • [1] Depth of focus of intraocular lenses with higher-order aberrations
    Zolotarev, A. V.
    Karlova, E. V.
    Kotova, S. P.
    Patlan, V. V.
    Russkov, K. N.
    Samagin, S. A.
    Saptsina, T. N.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2013, 40 (12) : 339 - 345
  • [2] Depth of focus of intraocular lenses with higher-order aberrations
    A. V. Zolotarev
    E. V. Karlova
    S. P. Kotova
    V. V. Patlan
    K. N. Russkov
    S. A. Samagin
    T. N. Saptsina
    Bulletin of the Lebedev Physics Institute, 2013, 40 : 339 - 345
  • [3] Measuring aberrations of multifocal and extended depth-of-focus intraocular lenses
    Del Aguila-Carrasco, Antonio J.
    Papadatou, Eleni
    Buckhurst, Phillip J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1516 - 1517
  • [4] Effect of Decentration on the Optical Quality of Monofocal, Extended Depth of Focus, and Bifocal Intraocular Lenses
    Xu, Jie
    Zheng, Tianyu
    Lu, Yi
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (08) : 484 - +
  • [5] Deployment of combined higher order aberrations to extend the depth of focus of lenses
    de Lima Monteiro, Davies William
    de Oliveira Costa, Rodolfo Felipe
    de Carvalho, Luiz Melk
    CURRENT DEVELOPMENTS IN LENS DESIGN AND OPTICAL ENGINEERING XX, 2019, 11104
  • [6] Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens
    Pilger, Daniel
    Homburg, David
    Brockmann, Tobias
    Torun, Necip
    Bertelmann, Eckart
    von Sonnleithner, Christoph
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) : 425 - 432
  • [7] Extended depth of focus intraocular lenses for presbyopia
    Akella, Sruti S.
    Juthani, Viral V.
    CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) : 319 - 323
  • [8] Comparison of Modal and Zonal Wavefront Measurements of Refractive Extended Depth of Focus Intraocular Lenses
    Yoon, Geunyoung
    Bang, Seungpil
    Jung, Hae
    Kim, Myoung
    Jun, Jong
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [9] Optimum Refractive Target in Patients with Bilateral Implantation of Extended Depth of Focus Intraocular Lenses
    Jackson, Mitchell A.
    Edmiston, Anna M.
    Bedi, Raman
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 455 - 462
  • [10] Comparison of modal and zonal wavefront measurements of refractive extended depth of focus intraocular lenses
    Bang, Seung Pil
    Jung, HaeWon
    Li, Kaccie Y.
    Yoon, Geunyoung
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (03) : 1618 - 1629