Optical Quality and Higher Order Aberrations of Refractive Extended Depth of Focus Intraocular Lenses

被引:7
|
作者
Baur, Isabella D. [1 ]
Yan, Weijia [1 ]
Auffarth, Gerd U. [1 ,2 ]
Khoramnia, Ramin [1 ]
Labuz, Grzegorz [1 ]
机构
[1] Heidelberg Univ, David J Apple Ctr Vis Res, Dept Ophthalmol, Heidelberg, Germany
[2] Heidelberg Univ, Dept Ophthalmol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
D O I
10.3928/1081597X-20230831-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the optical quality and higher order aberrations of four different refractive extended depth of focus intraocular lens (EDOF IOL) models (Lentis Comfort [Teleon Surgical BV], MiniWell (SIFI), LuxSmart [Bausch & Lomb], and AcrySof IQ Vivity [Alcon Laboratories, Inc]) and a monofocal IOL (Tecnis ZCB00; Johnson & Johnson Surgical Vision, Inc).METHODS: An optical metrology instrument (OptiSpheric IOL PRO2; Trioptics GmbH) was used to study image quality metrics of the different IOLs. The modulation transfer function (MTF) was measured at pupil sizes 1 to 5 mm in 1-mm steps. Area under the MTF and simulated visual acuity were calculated for different pupil diameters. Wavefront aberrations were measured with the SHS Ophthalmic device (Optocraft GmbH), which features a Hartmann-Shack sensor.RESULTS: All EDOF lenses yielded a simulated far visual acuity of 0.00 logMAR (20/20 Snellen) or better. At the 0.20 logMAR visual acuity level, the EDOF IOLs showed an increased depth of focus of at least 0.75 diopters compared to the monofocal IOL. Pupil dependency was more pronounced with the MiniWell, LuxSmart, and Vivity, whereas the Lentis showed a more consistent behavior at different apertures. The wavefront measurement revealed increased central aberrations for the MiniWell, LuxSmart, and Vivity IOL compared to the monofocal control.CONCLUSIONS: All EDOF IOLs demonstrated increased depth of focus while maintaining good simulated visual acuity at the far focus. Pupil dependency differed between the IOL models. The wavefront analysis revealed the complex design of the different EDOF IOLs with several zones with varying aberrations.
引用
收藏
页码:668 / 675
页数:8
相关论文
共 50 条
  • [31] Depth of focus in eyes with diffractive bifocal and refractive multifocal intraocular lenses
    Schmidinger, Gerald
    Geitzenauer, Wolfgang
    Hahsle, Bernhard
    Klemen, Ulrich-Michael
    Skorpik, Christian
    Pieh, Stefan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (10): : 1650 - 1656
  • [32] Pinhole Pupilloplasty for Higher Order Aberrations: Assessment of Visual Quality and Depth of Focus
    Narang, Priya
    Holladay, Jack
    Agarwal, Amar
    Gracy, Helen
    Kumar, Dhivya Ashok
    Sivagnanam, Soundari
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) : 812 - +
  • [33] Refractive Predictability of a Swept Source Optical Coherence Tomography Biometer in Long and Short Eyes Implanted with Extended Depth of Focus Intraocular Lenses
    Blehm, Clayton
    Hall, Brad
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3525 - 3530
  • [34] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [35] Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses
    Miaomiao Qin
    Min Ji
    Tianqiu Zhou
    Yurong Yuan
    Jiawei Luo
    Pengfei Li
    Ying Wang
    Xiaojuan Chen
    Wei Chen
    Huaijin Guan
    BMC Ophthalmology, 22
  • [36] Influence of angle alpha on visual quality after implantation of extended depth of focus intraocular lenses
    Qin, Miaomiao
    Ji, Min
    Zhou, Tianqiu
    Yuan, Yurong
    Luo, Jiawei
    Li, Pengfei
    Wang, Ying
    Chen, Xiaojuan
    Chen, Wei
    Guan, Huaijin
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [37] Visual and Refractive Outcomes of Diffractive Trifocal Versus Hybrid Multifocal-extended Depth of Focus Intraocular Lenses
    Kim, Ui Hwan
    Choi, Tae-Hoon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (12): : 1198 - 1207
  • [38] Patient-Reported Outcome Measures (PROMs) with Refractive and Diffractive Extended Depth of Focus (EDOF) Intraocular Lenses
    Banerjee, Shalini
    Kaufmann, Claude
    Tinner, Chiara
    Iselin, Katja
    Amstutz, Christoph Andreas
    Hedinger, Ying-Yu Melody
    Schmid, Martin K.
    Thiel, Michael
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (04) : 369 - 373
  • [39] Correction: Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens
    Aixa Alarcon
    Antonio del Aguila Carrasco
    Franck Gounou
    Henk Weeber
    Carmen Cánovas
    Patricia Piers
    Eye, 2025, 39 (1) : 204 - 204
  • [40] Changes in higher-order aberrations of intraocular lenses with intrascleral fixation
    Matsuki, Naoko
    Inoue, Makoto
    Itoh, Yuji
    Nagamoto, Toshiyuki
    Hirakatal, Akito
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (12) : 1732 - 1738