PURPOSE: To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes. MATERIALS AND METHODS: This is retrospective case series where subjects aged between 40-65 years and were implanted with LUCIDIS IOL by single surgeon were included. Subjects with Pre surgery corneal astigmatism > 1.50 D, corneal guttae, IOP >22mmHg, any ocular Co morbidities, Intra or post operative complication were excluded. At 1 month follow up, uncorrected visual acuities at distance (UCDVA), intermediate (UCIVA) and near (UCNVA), refraction were recorded. Internal Higher order aberrations and strehl ratio for a fixed pupil of 4mm and 6mm were calculated using NIDEK OPD Scan. Monocular defocus curve was obtained at 4 meter logMAR chart.RESULTS: Total of 55 eyes of 35 patients with mean +/- SD age of 58.50 +/- 7.49 years were evaluated. 89.09% of the eyes achieved visual acuity of 6/6. 49.09% could read N10 font at intermediate distance without any correction and 85.45% of the eyes had uncorrected near visual acuity of N6. Around 67% of the eyes did not require any refractive correction whereas around 26% of the eyes required correction upto +/- 0.25D. The defocus curve showed that visual acuity also ranges from 0.05 logMAR to 0.2 logMAR for Plano to -3.00D respectively. Mean +/- SD Strehl ratio at 4 and 6 mm pupil size was 0.06 +/- 0.04 and 0.02 +/- 0.02 respectively.CONCLUSION: Hybrid EDOF IOL such as LUCIDIS provides excellent vision at all distances. This could be attributed to IOL design which is spherical aberration neutral lens.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 50 条
  • [31] Implantation of a Small Aperture Intraocular Lens in Eyes with Irregular Corneas and Higher Order Aberrations
    Franco, Fabrizio
    Branchetti, Marco
    Vicchio, Lidia
    Serino, Federica
    Piergentili, Marco
    Spagnuolo, Vito
    Santoro, Francesca
    Virgili, Gianni
    Giansanti, Fabrizio
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (03) : 317 - 323
  • [32] Clinical Outcomes of Patients Implanted with Bifocal and Extended Depth of Focus Intraocular Lenses
    Park, Su Hwan
    Kim, Sung Il
    Ahn, Jung Hyo
    Shin, Jong Hoon
    Kim, Su Jin
    Lee, Ji Eun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (09): : 835 - 842
  • [33] Comparison of visual performance between extended depth of focus contact lens and single-vision contact lens in eyes with monofocal intraocular lens
    Takahiro Hiraoka
    Gaku Kiuchi
    Reia Hiraoka
    Junko Kotsuka
    Yumiko Kinoshita
    Tetsuro Oshika
    Japanese Journal of Ophthalmology, 2021, 65 : 803 - 809
  • [34] Comparison of visual performance between extended depth of focus contact lens and single-vision contact lens in eyes with monofocal intraocular lens
    Hiraoka, Takahiro
    Kiuchi, Gaku
    Hiraoka, Reia
    Kotsuka, Junko
    Kinoshita, Yumiko
    Oshika, Tetsuro
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (06) : 803 - 809
  • [35] Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
    Moshirfar, Majid
    Ellis, James
    Beesley, Daniel
    McCabe, Shannon E.
    Lewis, Adam
    Jnr, William B. West
    Ronquillo, Yasmyne
    Snr, Phillip Hoopes
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3051 - 3063
  • [36] Peripheral aberrations of pseudophakic eyes implanted with an aspheric monofocal intraocular lens
    Alarcon, Aixa
    Rosen, Robert
    Draschl, Petra
    Hirnschall, Nino
    Van der Mooren, Marrie
    Piers, Patricia A.
    Findl, Oliver
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] Outcomes and predictive factors in multifocal and extended depth of focus intraocular lens implantation
    de la Paz, Matthew
    Tsai, Linda M.
    CURRENT OPINION IN OPHTHALMOLOGY, 2024, 35 (01) : 28 - 33
  • [38] Clinical outcomes of an extended depth-of-focus intraocular lens in patients with glaucoma
    Dessouky, Reem Amir Kamal
    Aref, Amr
    Mermoud, Andre
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [39] Retrospective analysis on the visual outcomes and photic phenomena following bilateral extended depth of focus intraocular lens implants
    Lamba, Anmol
    Pereira, Austin
    Varma, Devesh
    Shahidi, Ayda
    Smith, Dean
    Ahmed, Iqbal K.
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2020, 55 (02): : 126 - 130
  • [40] Pinhole Pupilloplasty for Higher Order Aberrations: Assessment of Visual Quality and Depth of Focus
    Narang, Priya
    Holladay, Jack
    Agarwal, Amar
    Gracy, Helen
    Kumar, Dhivya Ashok
    Sivagnanam, Soundari
    JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (12) : 812 - +