Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens

被引:0
|
作者
Kenia, Vaishal P. [1 ]
Kenia, Raj V. [2 ]
Mudaliya, Laxmi [3 ]
Pirdankar, Onkar H. [4 ,5 ]
机构
[1] Kenia Eye Hosp, Dept Cataract & Refract Surg, Mumbai, Maharashtra, India
[2] Kenia Fdn, Dept Ophthalmol, Mumbai, Maharashtra, India
[3] Kenia Med & Res Fdn, Dept Clin Res, Mumbai, Maharashtra, India
[4] Kenia Med & Res Fdn, Dept Clin Res, Mumbai 400054, Maharashtra, India
[5] Kenia Med & Res Fdn, Mumbai 400054, Maharashtra, India
关键词
Extended Depth of Focus IOL; higher order aberrations; visual outcomes; OPTICAL-PERFORMANCE; QUALITY;
D O I
10.4103/tjo.tjo_16_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes. MATERIALS AND METHODS: This is retrospective case series where subjects aged between 40-65 years and were implanted with LUCIDIS IOL by single surgeon were included. Subjects with Pre surgery corneal astigmatism > 1.50 D, corneal guttae, IOP >22mmHg, any ocular Co morbidities, Intra or post operative complication were excluded. At 1 month follow up, uncorrected visual acuities at distance (UCDVA), intermediate (UCIVA) and near (UCNVA), refraction were recorded. Internal Higher order aberrations and strehl ratio for a fixed pupil of 4mm and 6mm were calculated using NIDEK OPD Scan. Monocular defocus curve was obtained at 4 meter logMAR chart.RESULTS: Total of 55 eyes of 35 patients with mean +/- SD age of 58.50 +/- 7.49 years were evaluated. 89.09% of the eyes achieved visual acuity of 6/6. 49.09% could read N10 font at intermediate distance without any correction and 85.45% of the eyes had uncorrected near visual acuity of N6. Around 67% of the eyes did not require any refractive correction whereas around 26% of the eyes required correction upto +/- 0.25D. The defocus curve showed that visual acuity also ranges from 0.05 logMAR to 0.2 logMAR for Plano to -3.00D respectively. Mean +/- SD Strehl ratio at 4 and 6 mm pupil size was 0.06 +/- 0.04 and 0.02 +/- 0.02 respectively.CONCLUSION: Hybrid EDOF IOL such as LUCIDIS provides excellent vision at all distances. This could be attributed to IOL design which is spherical aberration neutral lens.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 50 条
  • [21] A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens
    Ruiz-Mesa, Ramon
    Abengozar-Vela, Antonio
    Ruiz-Santos, Maria
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (02) : 182 - 187
  • [22] Comparative Evaluation of Visual Outcomes After Bilateral Implantation of a Diffractive Trifocal Intraocular Lens and an Extended Depth of Focus Intraocular Lens
    Singh, Bhupesh
    Sharma, Sourabh
    Dadia, Suchit
    Bharti, Neha
    Bharti, Sudhank
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2020, 46 (05): : 314 - 318
  • [23] Performance of Extended Depth of Focus Intraocular Lens in Eyes with Preexisting Retinal Disease
    Reitblat, Olga
    Velleman, David A.
    Levy, Adi
    Assia, Ehud I.
    Kleinmann, Guy
    OPHTHALMOLOGICA, 2024, 247 (04) : 241 - 250
  • [24] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Thomas Kohnen
    Myriam Böhm
    Eva Hemkeppler
    Sabrina Schönbrunn
    Nina DeLorenzo
    Kerstin Petermann
    Michael Herzog
    Eye, 2019, 33 : 1556 - 1563
  • [25] Visual performance of an extended depth of focus intraocular lens for treatment selection
    Kohnen, Thomas
    Boehm, Myriam
    Hemkeppler, Eva
    Schoenbrunn, Sabrina
    DeLorenzo, Nina
    Petermann, Kerstin
    Herzog, Michael
    EYE, 2019, 33 (10) : 1556 - 1563
  • [26] Effect of higher-order aberrations on visual function in keratoconic eyes with a rigid gas permeable contact lens
    Negishi, Kazuno
    Kumanomido, Takashi
    Utsumi, Yoshikazu
    Tsubota, Kazuo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (06) : 924 - 929
  • [27] Correlation of higher-order wavefront aberrations with visual function in pseudophakic eyes
    Hayashi, K.
    Yoshida, M.
    Hayashi, H.
    EYE, 2008, 22 (12) : 1476 - 1482
  • [28] Correlation of higher-order wavefront aberrations with visual function in pseudophakic eyes
    K Hayashi
    M Yoshida
    H Hayashi
    Eye, 2008, 22 : 1476 - 1482
  • [29] Initial Clinical Outcomes of a New Extended Depth of Focus Intraocular Lens
    Schallhorn, Steven C.
    Teenan, David
    Venter, Jan A.
    Hannan, Stephen J.
    Schallhorn, Julie M.
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (07) : 426 - +
  • [30] Higher-order Aberrations after Posterior Chamber Phakic Intraocular lens Implantation
    Liu, Hongting
    Li, Jing
    Agbedia, Owhofasa
    Wang, Jiangxia
    Li, Xinyu
    Wang, Hujie
    Liu, Lei
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)