Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens

被引:9
|
作者
Crema, Armando S. [1 ]
Walsh, Aileen [1 ]
Ventura, Bruna V. [2 ,3 ]
Santhiago, Marcony R. [1 ,4 ,5 ]
机构
[1] Rio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
[2] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[3] Altino Ventura Fdn, Recife, PE, Brazil
[4] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[5] Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
CATARACT-SURGERY; VECTOR ANALYSIS; BILATERAL IMPLANTATION; ASTIGMATIC CHANGES; PERFORMANCE; CORNEAL; ERROR;
D O I
10.3928/1081597X-20140530-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the predictability, efficacy, and safety of a ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). METHODS: This retrospective, noncomparative case study included 70 eyes of 44 patients implanted with a ReSTOR toric multifocal IOL (Alcon Laboratories, Inc., Fort Worth, TX). Patients were examined preoperatively and approximately 3 months postoperatively. Uncorrected and distance-corrected distance and near visual acuities were measured. Refractive and topographic astigmatism were recorded. Improvement, number of lines gained and lost, and correlation of attempted and achieved astigmatic correction values were also investigated as measurements of efficacy, safety, and predictability. RESULTS: Mean follow-up time was 2.3 +/- 1.2 months. Postoperative values of uncorrected distance and near visual acuity were 0.02 +/- 0.05 logMAR (20/21 +/- 20/22 Snellen) and 0.01 +/- 0.04 logMAR (20/20 +/- 20/22 Snellen), respectively. Statistical analyses revealed a significant improvement when comparing preoperative and postoperative values of manifest refraction spherical equivalent (P < .0001), uncorrected distance visual acuity (P < .0001), and astigmatism (P < .0001); 95.7% of eyes were 20/25 or better and 100% of eyes were 20/30 or better. At the last follow-up visit, none of the examined eyes had lost any lines. One hundred percent of the eyes remained unchanged or improved after surgery. Mean postoperative manifest refraction spherical equivalent was -0.06 +/- 0.27 at the last follow-up visit. The residual manifest astigmatism was 0.22 +/- 0.21. There was a highly significant correlation between preoperative attempted topographic astigmatism and postoperative achieved refractive astigmatism. CONCLUSIONS: The study provides clinical evidence that the new toric multifocal IOL seems to be predictable, safe, and effective, providing satisfactory visual acuity for far and near and correcting astigmatism.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [1] Visual and optical outcomes of a diffractive multifocal toric intraocular lens
    Ferreira, Tiago B.
    Marques, Eduardo F.
    Rodrigues, Antonio
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (07): : 1029 - 1035
  • [2] Visual and Refractive Outcomes of a Trifocal Toric Intraocular Lens Implanted in Eyes With High Corneal Astigmatism
    Ruiz-Mesa, Ramon
    Tana-Sanz, Pedro
    Tana-Sanz, Santiago
    Orts-Vila, Paz
    Tana-Rivero, Pedro
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (04) : 229 - +
  • [3] Medium-term visual and refractive outcomes in patients with pseudoexfoliation implanted with a toric or multifocal intraocular lens
    Rementeria-Capelo, Laureano A.
    Villar, Ester
    Puerto, Beatriz
    Lopez-Caballero, Cristina
    Fernandez-Cuenca, Sara
    Contreras, Ines
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (03) : 739 - 746
  • [4] Visual performance and rotational stability of a multifocal toric intraocular lens in myopic eyes
    Bai, Huiran
    Sun, Jiajun
    Shi, Xiujing
    Li, Honglei
    Wu, Xiaoming
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 261 (09) : 2557 - 2565
  • [5] Visual performance and rotational stability of a multifocal toric intraocular lens in myopic eyes
    Huiran Bai
    Jiajun Sun
    Xiujing Shi
    Honglei Li
    Xiaoming Wu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2023, 261 : 2557 - 2565
  • [6] Visual outcomes after implantation of a novel refractive toric multifocal intraocular lens
    Shimoda, Talita
    Shimoda, Gilberto
    Hida, Wilson Takashi
    Nakano, Celso Takashi
    Motta, Antonio Francisco
    Guimaraees, Aline Silva
    Tzelikis, Patrick Frensel M.
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (02) : 71 - 75
  • [7] Visual and refractive outcomes of monofocal toric intraocular lens implantation in amblyopic eyes
    Rementeria-Capelo, Laureano A.
    Fernandez-Cuenca, Sara
    Gros-Otero, Juan
    Garcia-Perez, Jorge L.
    Moran, Aida
    Contreras, Ines
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3425 - 3432
  • [8] Visual outcomes and optical quality after implantation of a diffractive multifocal toric intraocular lens
    Chen, Xiangfei
    Zhao, Ming
    Shi, Yuhua
    Yang, Liping
    Lu, Yan
    Huang, Zhenping
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (04) : 285 - 291
  • [9] Visual Performance and Rotational Stability of a Multifocal Toric Intraocular Lens
    Marques, Eduardo F.
    Ferreira, Tiago B.
    Simoes, Pedro
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 444 - 450
  • [10] Visual acuity and refraction with a diffractive multifocal toric intraocular lens
    Bellucci, Roberto
    Bauer, Noel J. C.
    Daya, Sheraz M.
    Visser, Nienke
    Santin, Giorgio
    Cargnoni, Miriam
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (10): : 1507 - 1518