Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens

被引:9
|
作者
Crema, Armando S. [1 ]
Walsh, Aileen [1 ]
Ventura, Bruna V. [2 ,3 ]
Santhiago, Marcony R. [1 ,4 ,5 ]
机构
[1] Rio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
[2] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[3] Altino Ventura Fdn, Recife, PE, Brazil
[4] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[5] Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
CATARACT-SURGERY; VECTOR ANALYSIS; BILATERAL IMPLANTATION; ASTIGMATIC CHANGES; PERFORMANCE; CORNEAL; ERROR;
D O I
10.3928/1081597X-20140530-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the predictability, efficacy, and safety of a ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). METHODS: This retrospective, noncomparative case study included 70 eyes of 44 patients implanted with a ReSTOR toric multifocal IOL (Alcon Laboratories, Inc., Fort Worth, TX). Patients were examined preoperatively and approximately 3 months postoperatively. Uncorrected and distance-corrected distance and near visual acuities were measured. Refractive and topographic astigmatism were recorded. Improvement, number of lines gained and lost, and correlation of attempted and achieved astigmatic correction values were also investigated as measurements of efficacy, safety, and predictability. RESULTS: Mean follow-up time was 2.3 +/- 1.2 months. Postoperative values of uncorrected distance and near visual acuity were 0.02 +/- 0.05 logMAR (20/21 +/- 20/22 Snellen) and 0.01 +/- 0.04 logMAR (20/20 +/- 20/22 Snellen), respectively. Statistical analyses revealed a significant improvement when comparing preoperative and postoperative values of manifest refraction spherical equivalent (P < .0001), uncorrected distance visual acuity (P < .0001), and astigmatism (P < .0001); 95.7% of eyes were 20/25 or better and 100% of eyes were 20/30 or better. At the last follow-up visit, none of the examined eyes had lost any lines. One hundred percent of the eyes remained unchanged or improved after surgery. Mean postoperative manifest refraction spherical equivalent was -0.06 +/- 0.27 at the last follow-up visit. The residual manifest astigmatism was 0.22 +/- 0.21. There was a highly significant correlation between preoperative attempted topographic astigmatism and postoperative achieved refractive astigmatism. CONCLUSIONS: The study provides clinical evidence that the new toric multifocal IOL seems to be predictable, safe, and effective, providing satisfactory visual acuity for far and near and correcting astigmatism.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [21] Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens
    Hayashi, Ken
    Manabe, Shin-ichi
    Yoshida, Motoaki
    Hayashi, Hideyuki
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08): : 1323 - 1329
  • [22] Rotational Stability and Visual Quality in Eyes With Rayner Toric Intraocular Lens Implantation
    Alberdi, Txomin
    Macias-Murelaga, Beatriz
    Bascaran, Lucia
    Goni, Nahia
    Saez de Arregui, Sandra
    Mendicute, Javier
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (10) : 696 - +
  • [23] Comparison of visual outcomes after implantation of diffractive trifocal toric intraocular lens and a diffractive apodized bifocal toric intraocular lens
    Gundersen, Kjell Gunnar
    Potvin, Rick
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 455 - 461
  • [24] Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
    Lee, Hun
    Lee, Kwanghyun
    Ahn, Ji Min
    Kim, Eung Kweon
    Sgrignoli, Bradford
    Kim, Tae-im
    YONSEI MEDICAL JOURNAL, 2014, 55 (05) : 1413 - 1420
  • [25] Evaluation of the True Wavefront Aberrations in Eyes Implanted With a Rotationally Asymmetric Multifocal Intraocular Lens
    Akondi, Vyas
    Perez-Merino, Pablo
    Martinez-Enriquez, Eduardo
    Dorronsoro, Carlos
    Alejandre, Nicolas
    Jimenez-Alfaro, Ignacio
    Marcos, Susana
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (04) : 257 - +
  • [26] Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child
    Zeng, Yanfeng
    Fan, Licheng
    Lu, Peirong
    CASE REPORTS IN OPHTHALMOLOGY, 2016, 7 (03): : 203 - 207
  • [27] Correlation of angle kappa and angle alpha on visual outcomes in eyes implanted with three types of multifocal intraocular lenses
    Ang, Robert Edward T.
    Doroy, Zoe Alethinos M.
    Yao, Justin Alan A.
    Cruz, Emerson M.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [28] Visual and Refractive Outcomes of a Toric Presbyopia-Correcting Intraocular Lens
    Epitropoulos, Alice T.
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016
  • [29] Visual and Refractive Outcomes of a New Hydrophobic Trifocal Toric Intraocular Lens
    Daya, Sheraz
    Lagana, Marcela Espinosa
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 997 - 1007
  • [30] Outcomes and complications of a multifocal toric intraocular lens with a surface-embedded near section
    Venter, Jan
    Pelouskova, Martina
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06): : 859 - 866