Visual Outcomes of Eyes Implanted With a Toric Multifocal Intraocular Lens

被引:9
|
作者
Crema, Armando S. [1 ]
Walsh, Aileen [1 ]
Ventura, Bruna V. [2 ,3 ]
Santhiago, Marcony R. [1 ,4 ,5 ]
机构
[1] Rio RioLaser Refract Surg Ctr, Rio De Janeiro, Brazil
[2] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Houston, TX 77030 USA
[3] Altino Ventura Fdn, Recife, PE, Brazil
[4] Univ Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[5] Univ Fed Rio de Janeiro, Dept Ophthalmol, Rio De Janeiro, Brazil
关键词
CATARACT-SURGERY; VECTOR ANALYSIS; BILATERAL IMPLANTATION; ASTIGMATIC CHANGES; PERFORMANCE; CORNEAL; ERROR;
D O I
10.3928/1081597X-20140530-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the predictability, efficacy, and safety of a ReSTOR multifocal intraocular lens (IOL) (Alcon Laboratories, Inc., Fort Worth, TX). METHODS: This retrospective, noncomparative case study included 70 eyes of 44 patients implanted with a ReSTOR toric multifocal IOL (Alcon Laboratories, Inc., Fort Worth, TX). Patients were examined preoperatively and approximately 3 months postoperatively. Uncorrected and distance-corrected distance and near visual acuities were measured. Refractive and topographic astigmatism were recorded. Improvement, number of lines gained and lost, and correlation of attempted and achieved astigmatic correction values were also investigated as measurements of efficacy, safety, and predictability. RESULTS: Mean follow-up time was 2.3 +/- 1.2 months. Postoperative values of uncorrected distance and near visual acuity were 0.02 +/- 0.05 logMAR (20/21 +/- 20/22 Snellen) and 0.01 +/- 0.04 logMAR (20/20 +/- 20/22 Snellen), respectively. Statistical analyses revealed a significant improvement when comparing preoperative and postoperative values of manifest refraction spherical equivalent (P < .0001), uncorrected distance visual acuity (P < .0001), and astigmatism (P < .0001); 95.7% of eyes were 20/25 or better and 100% of eyes were 20/30 or better. At the last follow-up visit, none of the examined eyes had lost any lines. One hundred percent of the eyes remained unchanged or improved after surgery. Mean postoperative manifest refraction spherical equivalent was -0.06 +/- 0.27 at the last follow-up visit. The residual manifest astigmatism was 0.22 +/- 0.21. There was a highly significant correlation between preoperative attempted topographic astigmatism and postoperative achieved refractive astigmatism. CONCLUSIONS: The study provides clinical evidence that the new toric multifocal IOL seems to be predictable, safe, and effective, providing satisfactory visual acuity for far and near and correcting astigmatism.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [31] Higher-order aberrations and visual function in pseudophakic eyes with a toric intraocular lens
    Hayashi, Ken
    Kondo, Hiroyuki
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Hirata, Akira
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1156 - 1165
  • [32] Evaluation of Visual Outcomes in Patients Implanted with Acri. LISA 356D Multifocal Intraocular Lens
    Yuvac, Sumeyra
    Unlu, Cihan
    Bayramlar, Huseyin
    Erdogan, Gurkan
    Guney, Esra
    Vural, Ece Turan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (04): : 236 - 242
  • [33] Visual outcomes in eyes with a distance-dominant diffractive multifocal intraocular lens with low near addition power
    Hayashi, Ken
    Ogawa, Soichiro
    Manabe, Shin-ichi
    Hirata, Akira
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2015, 99 (11) : 1466 - 1470
  • [34] Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    Joanna Rodriguez, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 241 - 250
  • [35] Comparative Analysis of Clinical Outcomes Obtained With a New Diffractive Multifocal Toric Intraocular Lens Implanted Through Two Types of Corneal Incision
    Mojzis, Peter
    Pinero, David P.
    Studeny, Pavel
    Tomas, Javier
    Korda, Vladimir
    Plaza, Ana B.
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (09) : 647 - 656
  • [36] Hydrophobic Trifocal Toric Intraocular Lens Outcomes in Japanese Eyes After Cataract Surgery
    Akahoshi, Takayuki
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 2021 - 2031
  • [37] Influence of pupil dynamics on near vision performance in eyes implanted with a diffractive multifocal intraocular lens
    Ferreira, Miriam Alves
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [38] Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens
    Kenia, Vaishal P.
    Kenia, Raj V.
    Mudaliya, Laxmi
    Pirdankar, Onkar H.
    TAIWAN JOURNAL OF OPHTHALMOLOGY, 2023, 13 (03) : 341 - 345
  • [39] Visual and Refractive Outcomes Following Exchange of an Opacified Multifocal Intraocular Lens
    Stewart, Stephen A.
    McNeely, Richard N.
    Chan, Wing C.
    Moore, Jonathan E.
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1883 - 1891
  • [40] Pupil Influence on the Visual Outcomes of a New-Generation Multifocal Toric Intraocular Lens With a Surface-Embedded Near Segment
    Wang, Mengmeng
    Corpuz, Christine Carole C.
    Huseynova, Tukezban
    Tomita, Minoru
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (02) : 90 - +