Visual outcomes and higher-order aberrations in eyes implanted with hybrid extended depth of focus intraocular lens

被引:0
|
作者
Kenia, Vaishal P. [1 ]
Kenia, Raj V. [2 ]
Mudaliya, Laxmi [3 ]
Pirdankar, Onkar H. [4 ,5 ]
机构
[1] Kenia Eye Hosp, Dept Cataract & Refract Surg, Mumbai, Maharashtra, India
[2] Kenia Fdn, Dept Ophthalmol, Mumbai, Maharashtra, India
[3] Kenia Med & Res Fdn, Dept Clin Res, Mumbai, Maharashtra, India
[4] Kenia Med & Res Fdn, Dept Clin Res, Mumbai 400054, Maharashtra, India
[5] Kenia Med & Res Fdn, Mumbai 400054, Maharashtra, India
关键词
Extended Depth of Focus IOL; higher order aberrations; visual outcomes; OPTICAL-PERFORMANCE; QUALITY;
D O I
10.4103/tjo.tjo_16_22
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the visual outcomes and higher order aberrations in eyes implanted with Hybrid EDOF IOL, particularly in Indian eyes. MATERIALS AND METHODS: This is retrospective case series where subjects aged between 40-65 years and were implanted with LUCIDIS IOL by single surgeon were included. Subjects with Pre surgery corneal astigmatism > 1.50 D, corneal guttae, IOP >22mmHg, any ocular Co morbidities, Intra or post operative complication were excluded. At 1 month follow up, uncorrected visual acuities at distance (UCDVA), intermediate (UCIVA) and near (UCNVA), refraction were recorded. Internal Higher order aberrations and strehl ratio for a fixed pupil of 4mm and 6mm were calculated using NIDEK OPD Scan. Monocular defocus curve was obtained at 4 meter logMAR chart.RESULTS: Total of 55 eyes of 35 patients with mean +/- SD age of 58.50 +/- 7.49 years were evaluated. 89.09% of the eyes achieved visual acuity of 6/6. 49.09% could read N10 font at intermediate distance without any correction and 85.45% of the eyes had uncorrected near visual acuity of N6. Around 67% of the eyes did not require any refractive correction whereas around 26% of the eyes required correction upto +/- 0.25D. The defocus curve showed that visual acuity also ranges from 0.05 logMAR to 0.2 logMAR for Plano to -3.00D respectively. Mean +/- SD Strehl ratio at 4 and 6 mm pupil size was 0.06 +/- 0.04 and 0.02 +/- 0.02 respectively.CONCLUSION: Hybrid EDOF IOL such as LUCIDIS provides excellent vision at all distances. This could be attributed to IOL design which is spherical aberration neutral lens.
引用
收藏
页码:341 / 345
页数:5
相关论文
共 50 条
  • [1] Higher-order aberrations and visual function in pseudophakic eyes with a toric intraocular lens
    Hayashi, Ken
    Kondo, Hiroyuki
    Yoshida, Motoaki
    Manabe, Shin-ichi
    Hirata, Akira
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1156 - 1165
  • [2] Depth of focus of intraocular lenses with higher-order aberrations
    A. V. Zolotarev
    E. V. Karlova
    S. P. Kotova
    V. V. Patlan
    K. N. Russkov
    S. A. Samagin
    T. N. Saptsina
    Bulletin of the Lebedev Physics Institute, 2013, 40 : 339 - 345
  • [3] Depth of focus of intraocular lenses with higher-order aberrations
    Zolotarev, A. V.
    Karlova, E. V.
    Kotova, S. P.
    Patlan, V. V.
    Russkov, K. N.
    Samagin, S. A.
    Saptsina, T. N.
    BULLETIN OF THE LEBEDEV PHYSICS INSTITUTE, 2013, 40 (12) : 339 - 345
  • [4] Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens
    Pilger, Daniel
    Homburg, David
    Brockmann, Tobias
    Torun, Necip
    Bertelmann, Eckart
    von Sonnleithner, Christoph
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (04) : 425 - 432
  • [5] Analysis of higher-order aberrations in eyes having undergone intraocular lens suturing
    Aizawa, Naoko
    Kunikata, Hiroshi
    Maeda, Naoyuki
    Nakazawa, Toru
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (01): : 92 - 94
  • [6] Effect of crystalline lens decentration and tilt on visual performance in eyes implanted with bifocal or extended depth of focus intraocular lenses
    Zhang, Yu
    Zhang, Jiaqing
    Liang, Chen
    Xu, Yifan
    Wu, Jiaying
    Wu, Junming
    Zhang, Yifan
    Jin, Aixia
    Tan, Xuhua
    Luo, Lixia
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [7] The Influence of Decentration on Higher-Order Aberrations in Artisan Aphakic Intraocular Lens Implantation Eyes
    Miao, Aizhu
    Zhang, Min
    Chen, Tianhui
    Lu, Yi
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [8] Optimizing higher-order aberrations with intraocular lens technology
    Bellucci, Roberto
    Morselli, Simonetta
    CURRENT OPINION IN OPHTHALMOLOGY, 2007, 18 (01) : 67 - 73
  • [9] Higher-order aberrations of intraocular lens with intrascleral fixation
    Inoue, Makoto
    Matsuki, Naoko
    Itoh, Yuji
    Nagamoto, Toshiyuki
    Hirakata, Akito
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [10] Visual Performance and Patient Satisfaction of Bilaterally Implanted Extended Depth of Focus Intraocular Lens: Outcomes of a Multicenter Registry
    Howes, Frank
    Rementeria-Capelo, Laureano A.
    Poyales, Francisco
    Borovik, Armand
    Khoramnia, Ramin
    Perez-Vives, Caridad
    Nuijts, Rudy M. M. A.
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)