High-performance amperometric determination of nitric oxide released by endothelial cells using flow injection analysis

被引:2
|
作者
Wenninger, Nadine [1 ]
Bernhart, Christina [1 ]
Kappaun, Wolfgang [2 ]
Kollau, Alexander [2 ]
Kalcher, Kurt [3 ]
Ortner, Astrid [1 ]
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmaceut Chem, Schubertstr 1, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmacol & Toxicol, Humboldtstr 46 I, A-8010 Graz, Austria
[3] Karl Franzens Univ Graz, Inst Chem, Dept Analyt Chem, Univ pl 1, A-8010 Graz, Austria
关键词
Nitric oxide; Flow injection analysis; Endothelial cells; Carbon paste electrode; Cardiovascular disease; SENSOR; ENOS; DYSFUNCTION; ELECTRODES; CALCIUM;
D O I
10.1016/j.talanta.2022.123810
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric flow injection analysis (FIA) method based on an optimized carbon paste electrode (CPE) for the determination of nitric oxide (NO) production from endothelial cells (ECs) was developed. The CPE was modified by Nafion, gold nanoparticles (AuNPs) and graphene nanoribbons (GNRs) via drop casting method. The proposed sensor exhibited excellent sensitivity and selectivity to the oxidation of NO with a linear correlation of 0.02 -22.4 mu M and a detection limit of 6 nM. The developed method is applied for real-time measurements of NO released from endothelial cells by stimulation of endothelial NO synthase (eNOS). Induction of NO synthesis by eNOS was successfully initiated by the calcium ionophore A23187, acetylcholine (ACh), or L-arginine. Furthermore, a reduction of eNOS activity could be observed after the addition of a NOS inhibitor, resulting in a decrease in NO signaling. Targeting eNOS could be of considerable value with regard to preventing or treating the development of cardiovascular diseases. The sensor's ease of fabrication and applicability for cell mea-surements enables the device to be used in pharmacological research and drug discovery.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Butmee, Preeyanut
    Prasertsri, Sarawut
    Pimmongkol, Saichol
    Tumcharern, Gamolwan
    Veseli, Albana
    Mehmeti, Eda
    Kalcher, Kurt
    Samphao, Anchalee
    MONATSHEFTE FUR CHEMIE, 2017, 148 (04): : 635 - 644
  • [32] Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors
    de Oliveira, Sanair M.
    Siguemura, Angelo
    Lima, Hugo O.
    de Souza, Flavia C.
    Magalhaes, Alvaro A. O.
    Toledo, Roberta M.
    D'Elia, Eliane
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (08) : 1399 - 1406
  • [34] Functionalised electrode array for the detection of nitric oxide released by endothelial cells using different NO-sensing chemistries
    Joshua Oni
    Alain Pailleret
    Sonnur Isik
    Nizam Diab
    Ina Radtke
    Andrea Blöchl
    Michael Jackson
    Fethi Bedioui
    Wolfgang Schuhmann
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1594 - 1600
  • [35] Functionalised electrode array for the detection of nitric oxide released by endothelial cells using different NO-sensing chemistries
    Oni, J
    Pailleret, A
    Isik, S
    Diab, N
    Radtke, I
    Blöchl, A
    Jackson, M
    Bedioui, F
    Schuhmann, W
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (06) : 1594 - 1600
  • [36] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [37] Characterization of an Amperometric Biosensor for the Determination of Biogenic Amines in Flow Injection Analysis
    Telsnig, Dietlind
    Kassarnig, Verena
    Zapf, Carmen
    Leitinger, Gerd
    Kalcher, Kurt
    Ortner, Astrid
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10476 - 10486
  • [38] Flow injection analysis of benzene using an amperometric bacterial biosensor
    Lanyon, YH
    Marrazza, G
    Tothill, IE
    Mascini, M
    ANALYTICAL LETTERS, 2004, 37 (08) : 1515 - 1528
  • [39] A novel amperometric sensor for the determination of nitric oxide, and its application in rat liver cells
    Chen, Xiao Xia
    Wang, Ying
    Hu, Sheng Shui
    MICROCHIMICA ACTA, 2008, 161 (1-2) : 255 - 263
  • [40] A novel amperometric sensor for the determination of nitric oxide, and its application in rat liver cells
    Xiao Xia Chen
    Ying Wang
    Sheng Shui Hu
    Microchimica Acta, 2008, 161 : 255 - 263