DETERMINATION OF TRACE CHROMIUM(Ⅵ) IN WATER BY FLOW INJECTION ANALYSIS WITH AN AMPEROMETRIC DETECTOR

被引:0
|
作者
Li Yuxian
机构
基金
美国国家科学基金会;
关键词
Cr; DETERMINATION OF TRACE CHROMIUM; IN WATER BY FLOW INJECTION ANALYSIS WITH AN AMPEROMETRIC DETECTOR; VI; HCI; Figure; Lake; rate; SCE;
D O I
暂无
中图分类号
学科分类号
摘要
A method for the determination of trace chromium(Ⅳ) in water by frow injection analysis with an amperometric detector has been developed. With a carrier solution of 1% NaCl and 0.1N HCl, chromium(Ⅵ) is determined in small sample volumes at a flow rate of 4.0mL/min, The applied potential is+100mV (vs. SCE). This method provides a detection limit of about 0.2μg/l, with a relative standard deviation of 1.6%. The method can be used for determination of chromium(Ⅵ) in natural water and industrial waste water.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF TRACE CHROMIUM(Ⅵ) IN WATER BY FLOW INJECTION ANALYSIS WITH AN AMPEROMETRIC DETECTOR
    Li Yuxian Li Fujun and Yah Huiyu Research Center for EcoEnvironmental Sciences Chinese Academy of Sciences P O Box Beijing Peoples Republic of China
    [J]. 中国科学院研究生院学报., 1989, (02) - 91
  • [2] DETERMINATION OF MITOXANTRONE BY FLOW-INJECTION ANALYSIS USING AN AMPEROMETRIC DETECTOR
    VILLAR, JCC
    GARCIA, AC
    BLANCO, PT
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (04) : 263 - 267
  • [3] DETERMINATION OF ORTHO-DIPHENOLS BY FLOW-INJECTION ANALYSIS WITH AN AMPEROMETRIC DETECTOR
    MATYSIK, J
    SOCZEWINSKI, E
    ZMINKOWSKAHALLIOP, E
    PRZEGALINSKI, M
    [J]. CHEMIA ANALITYCZNA, 1981, 26 (03): : 463 - 467
  • [4] Determination of ascorbic acid in pharmaceutical products by flow injection analysis using an amperometric detector
    Garrido, EM
    Lima, JLFC
    DelerueMatos, C
    [J]. FARMACO, 1995, 50 (12): : 881 - 884
  • [5] FLOW INJECTION ANALYSIS OF TRACE FREE CYANIDE IN SURFACE GROUND WATERS WITH AN AMPEROMETRIC FLOW-THROUGH DETECTOR
    马惠昌
    金莉
    严辉宇
    [J]. Science Bulletin, 1983, (08) : 1145 - 1145
  • [6] Determination of trace amounts of chromium (VI) by flow injection analysis with chemiluminescence detection
    Kanwal, Shamsa
    Ma, Qiang
    Dou, Wenchao
    Wang, Guannan
    Su, Xingguang
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2012, 92 (02) : 210 - 221
  • [7] FLOW-INJECTION ANODIC AMPEROMETRIC DETERMINATION OF CHROMIUM-III
    FAULDS, BR
    HUBER, CO
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 39 - ANYL
  • [8] Flow injection determination of acetylsalicylic acid in pharmaceutical preparations with an amperometric detector
    Garrido, JMPJ
    Lima, JLFC
    Matos, CD
    [J]. COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2000, 65 (06) : 954 - 962
  • [9] FLOW-INJECTION ANALYSIS OF TRACE FREE CYANIDE IN SURFACE GROUND WATERS WITH AN AMPEROMETRIC FLOW-THROUGH DETECTOR
    MA, HC
    JIN, L
    YAN, HY
    [J]. KEXUE TONGBAO, 1983, 28 (08): : 1145 - 1145
  • [10] Determination of trace chromium (VI) ion in chrome tanning agents by flow injection analysis
    Zhang, XS
    Jiang, XP
    Liu, MH
    Den, Y
    [J]. JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2000, 84 (06): : 255 - 257