Determination of trace amounts of chromium (VI) by flow injection analysis with chemiluminescence detection

被引:2
|
作者
Kanwal, Shamsa [1 ]
Ma, Qiang [1 ]
Dou, Wenchao [1 ]
Wang, Guannan [1 ]
Su, Xingguang [1 ]
机构
[1] Jilin Univ, Dept Analyt Chem, Coll Chem, Changchun 130012, Peoples R China
基金
中国国家自然科学基金;
关键词
chemiluminescence; flow injection analysis; trace amounts; Cr(VI); ATOMIC-ABSORPTION-SPECTROMETRY; WASTE-WATER; HEXAVALENT CHROMIUM; PRECONCENTRATION; PYROGALLOL; PERIODATE; EMISSION; CR(VI); SYSTEM; SEPARATION;
D O I
10.1080/03067310903353503
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensitive chemiluminescence (CL) method combined with continuous flow injection analysis is described for the determination of Cr(VI). Strong CL signals were generated by Cr(VI)-catalysed oxidation of gallic acid in the presence of potassium permanganate and hydrogen peroxide. Effects of reagent concentrations, temperature, pH, flow rates, mixing coil length and mixing flow sequences on the chemiluminescence intensity were studied. Under the optimised experimental conditions, the relationship between the logarithm of concentration (log C) of Cr(VI) and the logarithm of intensity (log I) is linear over the range of 2 x 10(-11)-5 x 10(-4) mol L-1, with the detection limit (3 sigma) of 4 x 10(-12) mol L-1. Relative standard deviation of ten measurements of 1 x 10(-9) mol L-1 Cr(VI) is 1.7%. This flow injection analysis (FIA) system proved to be able to analyse up to 40 samples h(-1). Effects of various interferences possibly present in the water samples were investigated. Most cations and anions, as well as organic compounds, did not interfere with the determination of Cr(VI) in water samples. The experimental results obtained for chromium in reference materials were also in good agreement with the certified values.
引用
收藏
页码:210 / 221
页数:12
相关论文
共 50 条
  • [1] Flow-injection determination of trace amounts of dopamine by chemiluminescence detection
    Zhang, LH
    Teshima, N
    Hasebe, T
    Kurihara, M
    Kawashima, T
    [J]. TALANTA, 1999, 50 (03) : 677 - 683
  • [2] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    [J]. ANALYST, 1994, 119 (08) : 1829 - 1833
  • [3] DETERMINATION OF TRACE AMOUNTS OF CHROMIUM(III) USING CHEMILUMINESCENCE ANALYSIS
    SEITZ, WR
    SUYDAM, WW
    HERCULES, DM
    [J]. ANALYTICAL CHEMISTRY, 1972, 44 (06) : 957 - &
  • [4] Determination of trace amounts of sulfide by flow-injection chemiluminescence method
    Du, JX
    Li, YH
    Lü, JR
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (02) : 189 - 191
  • [6] Determination of gossypol in trace level by flow injection analysis with chemiluminescence detection
    Xue, BC
    Liu, EB
    [J]. CHINESE CHEMICAL LETTERS, 2006, 17 (01) : 57 - 60
  • [7] Determination of trace chromium (VI) ion in chrome tanning agents by flow injection analysis
    Zhang, XS
    Jiang, XP
    Liu, MH
    Den, Y
    [J]. JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2000, 84 (06): : 255 - 257
  • [8] Determination of trace amounts of dopamine by flow-injection analysis coupled with luminol-Ag(III) complex chemiluminescence detection
    Xu, Xiangdong
    Shi, Hongmei
    Ma, Li
    Kang, Weijun
    Li, Shan
    [J]. LUMINESCENCE, 2011, 26 (02) : 93 - 100
  • [9] Determination of Trace Chromium(VI) in Tanning Wastewater by Flow Injection Spectrophotometry
    Zhao, Xin
    Sui, Zhihui
    Zhang, Jingbin
    [J]. ENVIRONMENT MATERIALS AND ENVIRONMENT MANAGEMENT PTS 1-3, 2010, 113-116 : 1732 - 1734
  • [10] Flow Injection Determination of Mo(VI), in Freshwaters with Luminol Chemiluminescence Detection
    Attiq-Ur-Rehman
    Yaqoob, Mohammad
    Waseem, Amir
    Nabi, Abdul
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2009, 31 (01): : 74 - 79