High-performance amperometric determination of nitric oxide released by endothelial cells using flow injection analysis

被引:2
|
作者
Wenninger, Nadine [1 ]
Bernhart, Christina [1 ]
Kappaun, Wolfgang [2 ]
Kollau, Alexander [2 ]
Kalcher, Kurt [3 ]
Ortner, Astrid [1 ]
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmaceut Chem, Schubertstr 1, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmacol & Toxicol, Humboldtstr 46 I, A-8010 Graz, Austria
[3] Karl Franzens Univ Graz, Inst Chem, Dept Analyt Chem, Univ pl 1, A-8010 Graz, Austria
关键词
Nitric oxide; Flow injection analysis; Endothelial cells; Carbon paste electrode; Cardiovascular disease; SENSOR; ENOS; DYSFUNCTION; ELECTRODES; CALCIUM;
D O I
10.1016/j.talanta.2022.123810
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric flow injection analysis (FIA) method based on an optimized carbon paste electrode (CPE) for the determination of nitric oxide (NO) production from endothelial cells (ECs) was developed. The CPE was modified by Nafion, gold nanoparticles (AuNPs) and graphene nanoribbons (GNRs) via drop casting method. The proposed sensor exhibited excellent sensitivity and selectivity to the oxidation of NO with a linear correlation of 0.02 -22.4 mu M and a detection limit of 6 nM. The developed method is applied for real-time measurements of NO released from endothelial cells by stimulation of endothelial NO synthase (eNOS). Induction of NO synthesis by eNOS was successfully initiated by the calcium ionophore A23187, acetylcholine (ACh), or L-arginine. Furthermore, a reduction of eNOS activity could be observed after the addition of a NOS inhibitor, resulting in a decrease in NO signaling. Targeting eNOS could be of considerable value with regard to preventing or treating the development of cardiovascular diseases. The sensor's ease of fabrication and applicability for cell mea-surements enables the device to be used in pharmacological research and drug discovery.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] CONSTANT-POTENTIAL AMPEROMETRIC DETECTOR FOR CARBOHYDRATES AT A NICKEL(III) OXIDE ELECTRODE FOR MICROSCALE FLOW-INJECTION ANALYSIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GOTO, M
    MIYAHARA, H
    ISHII, D
    JOURNAL OF CHROMATOGRAPHY, 1990, 515 : 213 - 220
  • [22] A high-performance amperometric sensor based on a monodisperse Pt–Au bimetallic nanoporous electrode for determination of hydrogen peroxide released from living cells
    Yu Zhong
    Meng-Meng Liu
    Yao Chen
    Yuan-Jie Yang
    Li-Na Wu
    Feng-qiao Bai
    Yun Lei
    Fei Gao
    Ai-Lin Liu
    Microchimica Acta, 2020, 187
  • [23] DETERMINATION OF TOBRAMYCIN USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    STATLER, JA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (01): : 244 - 246
  • [24] DETERMINATION OF DISSOLVED ALUMINUM SPECIES IN ACID WATERS USING FLOW-INJECTION ANALYSIS AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    SUTHEIMER, S
    CABANISS, SE
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 220 - ENVR
  • [25] FLUORIMETRIC DETERMINATION OF AFLATOXINS IN FOODSTUFFS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLOW-INJECTION ANALYSIS
    LAZARO, F
    DECASTRO, MDL
    VALCARCEL, M
    JOURNAL OF CHROMATOGRAPHY, 1988, 448 (01): : 173 - 181
  • [26] COMPARISON OF FLOW-INJECTION ANALYSIS WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF ETOPOSIDE IN PLASMA
    VANOPSTAL, MAJ
    KRABBENBORG, P
    HOLTHUIS, JJM
    VANBENNEKOM, WP
    BULT, A
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 432 : 395 - 400
  • [27] A high-performance amperometric sensor based on a monodisperse Pt-Au bimetallic nanoporous electrode for determination of hydrogen peroxide released from living cells
    Zhong, Yu
    Liu, Meng-Meng
    Chen, Yao
    Yang, Yuan-Jie
    Wu, Li-Na
    Bai, Feng-qiao
    Lei, Yun
    Gao, Fei
    Liu, Ai-Lin
    MICROCHIMICA ACTA, 2020, 187 (09)
  • [28] A biosensor for the determination of ammonium ion using flow injection amperometric system
    Preeyanut Butmee
    Sarawut Prasertsri
    Saichol Pimmongkol
    Gamolwan Tumcharern
    Albana Veseli
    Eda Mehmeti
    Kurt Kalcher
    Anchalee Samphao
    Monatshefte für Chemie - Chemical Monthly, 2017, 148 : 635 - 644
  • [30] Enhanced flow injection analysis for measurements of S-nitrosothiols species in biological samples using highly selective amperometric nitric oxide sensor
    Huang, Chun Cui
    Shao, Hui Bo
    CHINESE CHEMICAL LETTERS, 2012, 23 (02) : 229 - 232