High-performance amperometric determination of nitric oxide released by endothelial cells using flow injection analysis

被引:2
|
作者
Wenninger, Nadine [1 ]
Bernhart, Christina [1 ]
Kappaun, Wolfgang [2 ]
Kollau, Alexander [2 ]
Kalcher, Kurt [3 ]
Ortner, Astrid [1 ]
机构
[1] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmaceut Chem, Schubertstr 1, A-8010 Graz, Austria
[2] Karl Franzens Univ Graz, Inst Pharmaceut Sci, Dept Pharmacol & Toxicol, Humboldtstr 46 I, A-8010 Graz, Austria
[3] Karl Franzens Univ Graz, Inst Chem, Dept Analyt Chem, Univ pl 1, A-8010 Graz, Austria
关键词
Nitric oxide; Flow injection analysis; Endothelial cells; Carbon paste electrode; Cardiovascular disease; SENSOR; ENOS; DYSFUNCTION; ELECTRODES; CALCIUM;
D O I
10.1016/j.talanta.2022.123810
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric flow injection analysis (FIA) method based on an optimized carbon paste electrode (CPE) for the determination of nitric oxide (NO) production from endothelial cells (ECs) was developed. The CPE was modified by Nafion, gold nanoparticles (AuNPs) and graphene nanoribbons (GNRs) via drop casting method. The proposed sensor exhibited excellent sensitivity and selectivity to the oxidation of NO with a linear correlation of 0.02 -22.4 mu M and a detection limit of 6 nM. The developed method is applied for real-time measurements of NO released from endothelial cells by stimulation of endothelial NO synthase (eNOS). Induction of NO synthesis by eNOS was successfully initiated by the calcium ionophore A23187, acetylcholine (ACh), or L-arginine. Furthermore, a reduction of eNOS activity could be observed after the addition of a NOS inhibitor, resulting in a decrease in NO signaling. Targeting eNOS could be of considerable value with regard to preventing or treating the development of cardiovascular diseases. The sensor's ease of fabrication and applicability for cell mea-surements enables the device to be used in pharmacological research and drug discovery.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Determination of stevioside by high-performance liquid chromatography with pulsed amperometric detection
    Ahmed, MJ
    Smith, RM
    JOURNAL OF SEPARATION SCIENCE, 2002, 25 (03): : 170 - 172
  • [42] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETERMINATION OF PLASMA TYRAMINE
    CAUSON, RC
    BROWN, MJ
    JOURNAL OF CHROMATOGRAPHY, 1984, 317 (DEC): : 319 - 325
  • [43] Stability and determination of aflatoxins by high-performance liquid chromatography with amperometric detection
    Elizalde-González, MP
    Mattusch, J
    Wennrich, R
    JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 439 - 444
  • [44] DETERMINATION OF PEROXIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION
    FUNK, MO
    KELLER, MB
    LEVISON, B
    ANALYTICAL CHEMISTRY, 1980, 52 (04) : 771 - 773
  • [45] Determination of stevioside by high-performance liquid chromatography with pulsed amperometric detection
    Ahmed, M. Jamaluddin
    Smith, Roger M.
    Journal of Separation Science, 2002, 25 (03) : 170 - 172
  • [46] DETERMINATION OF AMOXICILLIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION
    BROOKS, MA
    HACKMAN, MR
    MAZZO, DJ
    JOURNAL OF CHROMATOGRAPHY, 1981, 210 (03): : 531 - 535
  • [47] Differential amperometric determination of hydrogen peroxide in honeys using flow-injection analysis with enzymatic reactor
    de Abreu Franchini, Romulo Augusto
    Costa Matos, Maria Auxiliadora
    Colombara, Rosana
    Matos, Renato Camargo
    TALANTA, 2008, 75 (01) : 301 - 306
  • [48] Flow-through amperometric determination of ampicillin using a copper electrode in a batch injection analysis system
    Veloso, William Barros
    Correa Ribeiro, Geyse Adriana
    da Rocha, Claudia Quintino
    Tanaka, Auro Atsushi
    da Silva, Iranaldo Santos
    Ferreira Dantas, Luiza Maria
    MEASUREMENT, 2020, 155 (155)
  • [49] Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes
    Guzmán, A
    Agüí, L
    Pedrero, M
    Yáñez-Sedeño, P
    Pingarrón, JM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 923 - 933
  • [50] Flow injection analysis with amperometric detection for iodide determination as a tracer in seawater reservoirs
    Flávia C. de Souza
    Davi Augusto Izidro da Silva
    Márcia Simões
    Roberto Barros Faria
    Maria Aparecida de Melo
    Roberta Maciel Toledo
    Eliane D’Elia
    Journal of Applied Electrochemistry, 2012, 42 : 585 - 593