Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors

被引:9
|
作者
de Oliveira, Sanair M. [1 ]
Siguemura, Angelo [1 ]
Lima, Hugo O. [1 ]
de Souza, Flavia C. [1 ]
Magalhaes, Alvaro A. O. [2 ]
Toledo, Roberta M. [2 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Petrobras SA, Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941915 Rio De Janeiro, RJ, Brazil
关键词
morpholine; corrosion inhibitors; amperometry; screen-printed electrodes; flow injection analysis; CHROMATOGRAPHIC DETERMINATION; MILD-STEEL; GAS; CYCLOHEXYLAMINE; DERIVATIVES; WATER; PARACETAMOL; ELECTRODES; QUINOLINE; AMINES;
D O I
10.5935/0103-5053.20140122
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, an electrochemical method is proposed using flow injection analysis and amperometric detection with screen-printed carbon electrodes for morpholine determination to monitor the quality of morpholine-based commercial inhibitors and the residual concentration of inhibitors that control internal corrosion in oil industry pipelines. The amperometric method resulted in a strong linear correlation coefficient (r = 0.9941) with a linear response over a concentration range of 20-120 mg L-1, a limit of detection of 10 mg L-1 and a limit of quantification of 30 mg L-1. In addition, the method has been shown to be precise, linear and homoscedastic. The recovery for the amperometric method was 100 +/- 6%, and the recovery for the real condensate sample was 99 +/- 2%. Thus, the proposed method is promising for analysing morpholine-based commercial inhibitors in oil industry pipelines with simple and low-cost methodologies compared with ion chromatography techniques.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 50 条
  • [1] Determination of esterase activity by flow injection analysis with amperometric detection
    Takamura, K
    Fuse, T
    Kusu, F
    ANALYTICAL SCIENCES, 1996, 12 (02) : 343 - 347
  • [2] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [3] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [4] Flow injection analysis with amperometric detection for iodide determination as a tracer in seawater reservoirs
    Flávia C. de Souza
    Davi Augusto Izidro da Silva
    Márcia Simões
    Roberto Barros Faria
    Maria Aparecida de Melo
    Roberta Maciel Toledo
    Eliane D’Elia
    Journal of Applied Electrochemistry, 2012, 42 : 585 - 593
  • [5] DETERMINATION OF SULFUR-DIOXIDE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    GRANADOS, M
    MASPOCH, S
    BLANCO, M
    ANALYTICA CHIMICA ACTA, 1986, 179 : 445 - 451
  • [6] DETERMINATION OF ORTHO-PHOSPHATE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    HARDEN, SM
    NONIDEZ, WK
    ANALYTICAL CHEMISTRY, 1984, 56 (12) : 2218 - 2223
  • [7] DETERMINATION OF NIMESULIDE BY FLOW INJECTION ANALYSIS WITH MULTIPLE-PULSE AMPEROMETRIC DETECTION
    Lima, Amanda Barbosa
    Chaves, Sandro Cruz
    da Silva, Leonardo Morais
    Pereira, Polyana Fernandes
    Richter, Eduardo Mathias
    Pio dos Santos, Wallans Torres
    QUIMICA NOVA, 2013, 36 (09): : 1296 - U252
  • [8] INDIRECT DETERMINATION OF BROMIDE BY DIFFUSION FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    NIKOLIC, SD
    JANKOVIC, TD
    MILOSAVLJEVIC, EB
    HENDRIX, JL
    NELSON, JH
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2): : 98 - 102
  • [9] Flow injection analysis with amperometric detection for iodide determination as a tracer in seawater reservoirs
    de Souza, Flavia C.
    Izidro da Silva, Davi Augusto
    Simoes, Marcia
    Faria, Roberto Barros
    de Melo, Maria Aparecida
    Toledo, Roberta Maciel
    D'Elia, Eliane
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2012, 42 (08) : 585 - 593
  • [10] Determination of cyanide in microsamples by means of capillary flow injection analysis with amperometric detection
    Backofen, U
    Matysik, FM
    Werner, G
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (3-4): : 271 - 273