INDIRECT DETERMINATION OF BROMIDE BY DIFFUSION FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION

被引:7
|
作者
NIKOLIC, SD
JANKOVIC, TD
MILOSAVLJEVIC, EB
HENDRIX, JL
NELSON, JH
机构
[1] UNIV BELGRADE, FAC CHEM, POB 550, YU-11001 BELGRADE, YUGOSLAVIA
[2] UNIV NEVADA, MACKAY SCH MINES, DEPT CHEM, RENO, NV 89557 USA
[3] UNIV NEVADA, MACKAY SCH MINES, DEPT CHEM & MET ENGN, RENO, NV 89557 USA
来源
关键词
D O I
10.1007/BF00321701
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid, indirect diffusion flow injection analysis (FIA) method with amperometric detection has been developed for the selective and sensitive determination of Br-. The method is based on permanganate oxidation of Br- to bromine. Bromine diffuses through a PTFE membrane and is quantified amperometrically at a platinum working electrode. Calibration graphs were linear up to the maximum concentration of Br- investigated (10.0 mmol/l). The precision of the technique was better than a relative standard deviation of 0.7% at 10.0-mu-mol/l, with a throughput of 30 samples per hour. The effects of temperature, acidity, working potential, composition of the reagent solution and interferents on the FIA signals were studied. The catalytic effect of Cl- on the permanganate oxidation of the analyte was utilized to lower the detection limit to 1-mu-mol/l (16 ng Br-). Similar detection limits were achieved by combining the effects of higher acidity (4.0 mol/l H2SO4) and elevated temperatures (40-degrees-C). The method was successfully applied to the determination of Br- in chloride and other reagents, as well as in natural waters.
引用
收藏
页码:98 / 102
页数:5
相关论文
共 50 条
  • [1] INDIRECT DETERMINATION OF CHLORIDE BY GAS-DIFFUSION FLOW-INJECTION WITH AMPEROMETRIC DETECTION
    NIKOLIC, SD
    MILOSAVLJEVIC, EB
    HENDRIX, JL
    NELSON, JH
    [J]. ANALYST, 1991, 116 (01) : 49 - 52
  • [2] FLOW-INJECTION ANALYSIS FOR ALUMINUM WITH INDIRECT AMPEROMETRIC DETECTION
    DOWNARD, AJ
    POWELL, HKJ
    XU, SH
    [J]. ANALYTICA CHIMICA ACTA, 1992, 256 (01) : 117 - 123
  • [3] INDIRECT DETERMINATION OF IRON IN A FLOW-INJECTION SYSTEM WITH AMPEROMETRIC DETECTION
    SILVA, L
    LEON, LE
    CALVO, A
    [J]. ANALYTICA CHIMICA ACTA, 1987, 192 (02) : 349 - 353
  • [4] INDIRECT DETERMINATION OF RARE-EARTHS BY AMPEROMETRIC DETECTION FOR FLOW-INJECTION ANALYSIS
    YEO, IH
    CHOI, KC
    EOM, TY
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1991, 12 (01) : 10 - 12
  • [5] INDIRECT DETERMINATION OF TETRAHYDROBORATE (BH4-) BY GAS-DIFFUSION FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    NIKOLIC, SD
    MILOSAVLJEVIC, EB
    HENDRIX, JL
    NELSON, JH
    [J]. TALANTA, 1993, 40 (08) : 1283 - 1287
  • [6] DETERMINATION OF BROMAZEPAM BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    ZAROBE, ER
    BLANCO, MH
    ABAD, EL
    HERNANDEZ, YL
    [J]. ANALES DE QUIMICA SERIE B-QUIMICA INORGANICA Y QUIMICA ANALYTICA, 1988, 84 (01): : 120 - 122
  • [7] DETERMINATION OF THE PESTICIDE GUTHION BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    [J]. ELECTROANALYSIS, 1990, 2 (06) : 487 - 491
  • [8] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF DIFFUSION-COEFFICIENTS
    YANG, JN
    YAO, ZH
    GAO, ZP
    [J]. ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 341 - 346
  • [9] DETERMINATION OF SULFUR-DIOXIDE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    GRANADOS, M
    MASPOCH, S
    BLANCO, M
    [J]. ANALYTICA CHIMICA ACTA, 1986, 179 : 445 - 451
  • [10] DETERMINATION OF ORTHO-PHOSPHATE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    HARDEN, SM
    NONIDEZ, WK
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (12) : 2218 - 2223