Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors

被引:9
|
作者
de Oliveira, Sanair M. [1 ]
Siguemura, Angelo [1 ]
Lima, Hugo O. [1 ]
de Souza, Flavia C. [1 ]
Magalhaes, Alvaro A. O. [2 ]
Toledo, Roberta M. [2 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Petrobras SA, Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941915 Rio De Janeiro, RJ, Brazil
关键词
morpholine; corrosion inhibitors; amperometry; screen-printed electrodes; flow injection analysis; CHROMATOGRAPHIC DETERMINATION; MILD-STEEL; GAS; CYCLOHEXYLAMINE; DERIVATIVES; WATER; PARACETAMOL; ELECTRODES; QUINOLINE; AMINES;
D O I
10.5935/0103-5053.20140122
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, an electrochemical method is proposed using flow injection analysis and amperometric detection with screen-printed carbon electrodes for morpholine determination to monitor the quality of morpholine-based commercial inhibitors and the residual concentration of inhibitors that control internal corrosion in oil industry pipelines. The amperometric method resulted in a strong linear correlation coefficient (r = 0.9941) with a linear response over a concentration range of 20-120 mg L-1, a limit of detection of 10 mg L-1 and a limit of quantification of 30 mg L-1. In addition, the method has been shown to be precise, linear and homoscedastic. The recovery for the amperometric method was 100 +/- 6%, and the recovery for the real condensate sample was 99 +/- 2%. Thus, the proposed method is promising for analysing morpholine-based commercial inhibitors in oil industry pipelines with simple and low-cost methodologies compared with ion chromatography techniques.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 50 条
  • [31] Flow injection analysis with amperometric detection of cocaine in confiscated samples
    FernandezAbedul, MT
    CostaGarcia, A
    ANALYTICA CHIMICA ACTA, 1996, 328 (01) : 67 - 71
  • [32] FLOW-INJECTION ANALYSIS FOR ALUMINUM WITH INDIRECT AMPEROMETRIC DETECTION
    DOWNARD, AJ
    POWELL, HKJ
    XU, SH
    ANALYTICA CHIMICA ACTA, 1992, 256 (01) : 117 - 123
  • [33] FLOW-INJECTION ANALYSIS OF WARFARIN SODIUM WITH AMPEROMETRIC DETECTION
    BELAL, F
    ANDERSON, JL
    MIKROCHIMICA ACTA, 1985, 2 (3-4) : 145 - 151
  • [34] AMPEROMETRIC DETECTION FOR CAPILLARY-FLOW INJECTION-ANALYSIS
    WANG, J
    CHEN, L
    TALANTA, 1995, 42 (03) : 385 - 389
  • [35] DETERMINATION OF PARATHION IN THE PRESENCE OF PARAOXON AND PARA-NITROPHENOL BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION
    MENDEZ, JH
    MARTINEZ, RC
    GONZALO, ER
    TRANCON, JP
    ANALYTICA CHIMICA ACTA, 1990, 228 (02) : 317 - 321
  • [36] Determination of mercury(II) at trace levels by gas-diffusion flow injection analysis with amperometric detection
    Amini, N
    Cardwell, TJ
    Cattrall, RW
    Kolev, S
    ANALYTICA CHIMICA ACTA, 2005, 539 (1-2) : 203 - 207
  • [37] Determination of Ethanol in Alcoholic Drinks: Flow Injection Analysis with Amperometric Detection Versus Portable Raman Spectrometer
    Jashari, Granit
    Svancara, Ivan
    Sys, Milan
    ELECTROANALYSIS, 2020, 32 (09) : 1949 - 1956
  • [38] DETERMINATION OF MITOXANTRONE BY FLOW-INJECTION ANALYSIS USING AN AMPEROMETRIC DETECTOR
    VILLAR, JCC
    GARCIA, AC
    BLANCO, PT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (04) : 263 - 267
  • [39] FLOW-INJECTION DETERMINATION OF METHIONINE WITH AMPEROMETRIC DETECTION AT A STABLE MODIFIED ELECTRODE
    COX, JA
    DABEKZLOTORZYNSKA, E
    ELECTROANALYSIS, 1991, 3 (03) : 239 - 242
  • [40] Flow injection and HPLC determination of furosemide using pulsed amperometric detection at microelectrodes
    Guzmán, A
    Agüí, L
    Pedrero, M
    Yáñez-Sedeño, P
    Pingarrón, JM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (05) : 923 - 933