Flow Injection Analysis with Amperometric Detection for Morpholine Determination in Corrosion Inhibitors

被引:9
|
作者
de Oliveira, Sanair M. [1 ]
Siguemura, Angelo [1 ]
Lima, Hugo O. [1 ]
de Souza, Flavia C. [1 ]
Magalhaes, Alvaro A. O. [2 ]
Toledo, Roberta M. [2 ]
D'Elia, Eliane [1 ]
机构
[1] Univ Fed Rio de Janeiro, Inst Quim, BR-21941909 Rio De Janeiro, RJ, Brazil
[2] Petrobras SA, Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941915 Rio De Janeiro, RJ, Brazil
关键词
morpholine; corrosion inhibitors; amperometry; screen-printed electrodes; flow injection analysis; CHROMATOGRAPHIC DETERMINATION; MILD-STEEL; GAS; CYCLOHEXYLAMINE; DERIVATIVES; WATER; PARACETAMOL; ELECTRODES; QUINOLINE; AMINES;
D O I
10.5935/0103-5053.20140122
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, an electrochemical method is proposed using flow injection analysis and amperometric detection with screen-printed carbon electrodes for morpholine determination to monitor the quality of morpholine-based commercial inhibitors and the residual concentration of inhibitors that control internal corrosion in oil industry pipelines. The amperometric method resulted in a strong linear correlation coefficient (r = 0.9941) with a linear response over a concentration range of 20-120 mg L-1, a limit of detection of 10 mg L-1 and a limit of quantification of 30 mg L-1. In addition, the method has been shown to be precise, linear and homoscedastic. The recovery for the amperometric method was 100 +/- 6%, and the recovery for the real condensate sample was 99 +/- 2%. Thus, the proposed method is promising for analysing morpholine-based commercial inhibitors in oil industry pipelines with simple and low-cost methodologies compared with ion chromatography techniques.
引用
收藏
页码:1399 / 1406
页数:8
相关论文
共 50 条
  • [42] Flow Injection System with Amperometric Detection for Determination of Iodine Value of Vegetable Oils
    Kruatian, Thidarat
    Jitmanee, Kritsana
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2021, 48 (02): : 557 - 567
  • [43] FLOW-INJECTION AMPEROMETRIC DETERMINATION OF PHARMACEUTICALS
    GONZALEZ, F
    TARIN, P
    MASPOCH, S
    BLANCO, M
    ARCHIV DER PHARMAZIE, 1988, 321 (10) : 725 - 728
  • [44] Characterization of an Amperometric Biosensor for the Determination of Biogenic Amines in Flow Injection Analysis
    Telsnig, Dietlind
    Kassarnig, Verena
    Zapf, Carmen
    Leitinger, Gerd
    Kalcher, Kurt
    Ortner, Astrid
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (11): : 10476 - 10486
  • [45] FAST DETERMINATION OF HYDROQUINONE BY BATCH INJECTION ANALYSIS (BIA) WITH AMPEROMETRIC DETECTION
    Cunha, Rafael Rodrigues
    Tormin, Thiago Faria
    Richter, Eduardo Mathias
    Abarza Munoz, Rodrigo Alejandro
    QUIMICA NOVA, 2013, 36 (05): : 663 - 668
  • [46] Flow injection analysis of tetracycline in pharmaceutical formulation with pulsed amperometric detection
    Palaharn, S
    Charoenraks, T
    Wangfuengkanagul, N
    Grudpan, K
    Chailapakul, O
    ANALYTICA CHIMICA ACTA, 2003, 499 (1-2) : 191 - 197
  • [47] FLOW-INJECTION ANALYSIS WITH ALTERNATING-CURRENT AMPEROMETRIC DETECTION
    CURRAN, DJ
    GELBERT, MB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 192 : 101 - ANYL
  • [48] FLOW INJECTION ANALYSIS WITH MULTIPLE PULSE AMPEROMETRIC DETECTION: POTENTIALITIES AND APPLICATIONS
    Pio dos Santos, Wallans Torres
    Gimenes, Denise Tofanello
    Richter, Eduardo Mathias
    Angnes, Lucio
    QUIMICA NOVA, 2011, 34 (10): : 1753 - 1761
  • [49] PULSED-POTENTIAL AMPEROMETRIC DETECTION IN FLOW-INJECTION ANALYSIS
    JOHNSON, DC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 182 (AUG): : 42 - ANYL
  • [50] FLOW INJECTION ANALYSIS FOR AMPEROMETRIC DETECTION OF GLUCOSE WITH IMMOBILIZED ENZYME REACTOR
    Nenkova, R.
    Atanasova, R.
    Ivanova, D.
    Godjevargova, T.
    BIOTECHNOLOGY & BIOTECHNOLOGICAL EQUIPMENT, 2010, 24 (03) : 1986 - 1992