Measurement of Occupational Eye and Thyroid Radiation Doses in Pediatric Interventional Cardiologists at a Tertiary Hospital

被引:3
|
作者
Khafaji, Mawya [1 ]
Ashour, Tariq M. [2 ]
Mozahim, Naif F. [2 ]
Tashkandi, Abdullah [2 ]
Alqarni, Basil [2 ]
Malaikah, Abdulrahman A. [2 ]
Bagabas, Abdulaziz K. [2 ]
Alwasabi, Abdullah A. [2 ]
Albahiti, Sarah K. [1 ]
机构
[1] King Abdulaziz Univ, Fac Med, Radiol Dept, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Fac Med, Jeddah, Saudi Arabia
关键词
thyroid dose; eye lens dose; staff exposure; intervention pediatric cardiology; occupational radiation dose; cardiac catheterization; STAFF; EXTREMITIES; EXPOSURE; SCATTER;
D O I
10.7759/cureus.44894
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Advances in imaging techniques have led to increased utilization of imaging devices in catheterization laboratories. Invasive surgical procedures for cardiac disorders have been largely replaced by fluoroscopic cardiac catheterization. With this increase, concerns and risks associated with exposure to ionizing radiation among interventional cardiologists are growing. This study aims to measure and compare the occupational doses to the eye lens and thyroid of pediatric interventional cardiologists during different procedures in the catheterization laboratory and its significance. Methodology In this study, cardiologists wore bandanas with attached dosimeters to measure the absorbed doses to the eyes and thyroid gland. The dosimeters were collected for reading. The procedure types were also collected. In addition, the total fluoroscopy time and tube voltage of the biplane machine were measured. SPSS version 23 (IBM Corp., Armonk, NY, USA) was used to analyze the data. The characteristics of the study sample were described using simple counts and percentages, whereas means and standard deviations were used for continuous variables. Statistical significance was set at p-values <0.05. Results A total of 93 procedures were evaluated. The mean absorbed doses for all 93 procedures in both eyes and thyroid were 0.09 mGy and 0.08 mGy, respectively. A significant difference was found between the left and right eye measurements (p = 0.034), with higher doses administered to the left eye. However, no significant difference was observed between the right and left thyroid doses (p = 0.281). Significant correlations were found between the eye and thyroid doses and the procedure type (p = 0.02 and p = 0.009, respectively). Conclusions A significant amount of radiation was measured in the measurements of both organs. In addition, radiation dose measurements varied between different types of procedures. Our current results indicate the importance and necessity of applying the radiation protection concept of dose optimization.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Occupational radiation exposure to the lens of the eye in interventional radiology
    Moriarty, Heather K.
    Clements, Warren
    Phan, Tuan
    Wang, Sherry
    Goh, Gerard S.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (01) : 34 - 40
  • [22] The Relationship Between Eye Lens Doses and Occupational Doses for Different Centres of Interventional Cardiology
    Sukupova, Lucie
    Cemusova, Zina
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 541 - 544
  • [23] CORRELATION OF EYE LENS DOSES AND PERSONAL DOSE EQUIVALENT MEASURED ON THE ARM OF INTERVENTIONAL CARDIOLOGISTS FOR A RETROSPECTIVE ASSESSMENT OF DOSES TO OPERATORS' EYE LENS
    Domienik-Andrzejewska, Joanna
    Brodecki, Marcin
    Zmyslony, Marek
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (03) : 271 - 278
  • [24] Monte Carlo simulations of occupational radiation doses in interventional radiology
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 460 - 468
  • [25] Occupational eye lens doses in interventional cardiology. A multicentric study
    Sanchez, R. M.
    Vano, E.
    Fernandez, J. M.
    Pifarre, X.
    Ordiales, J. M.
    Rovira, J. J.
    Carrera, F.
    Goicolea, J.
    Fernandez-Ortiz, A.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (01) : 133 - 143
  • [26] Response to: Occupational radiation exposure to the lens of the eye in interventional radiology
    Chaudhary, Neera
    Turner, Julia
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2022, 66 (05) : 641 - 642
  • [27] Etiology of Pediatric Uveitis in a Tertiary Pediatric Eye Hospital in Egypt
    Latif, Eiman Abd El
    Mousa, Rasha
    Mahdi, Mohammed Tawfeeq
    Amin, Ahmed Mahmoud
    Ali, Mahmoud Mohammed Ahmed
    Abdelhamid, Nour Eldin
    Elmoddather, Mohamed
    Yousef, Hassan Shamselden
    Hafez, Ehab Hafez Gouda
    Salem, Sameh Galal Taher
    Soliman, Ashraf Hassan
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2023, 31 (10) : 1978 - 1983
  • [28] Patient radiation doses and reference levels in pediatric interventional radiology
    Geryes, Bouchra Habib
    Bak, Adeline
    Lachaux, Julie
    Ozanne, Augustin
    Boddaert, Nathalie
    Brunelle, Francis
    Naggara, Olivier
    Saliou, Guillaume
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3983 - 3990
  • [29] Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures
    Efstathopoulos, E. P.
    Pantos, I.
    Andreou, M.
    Gkatzis, A.
    Carinou, E.
    Koukorava, C.
    Kelekis, N. L.
    Brountzos, E.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 70 - 77
  • [30] Patient radiation doses and reference levels in pediatric interventional radiology
    Bouchra Habib Geryes
    Adeline Bak
    Julie Lachaux
    Augustin Ozanne
    Nathalie Boddaert
    Francis Brunelle
    Olivier Naggara
    Guillaume Saliou
    European Radiology, 2017, 27 : 3983 - 3990