Measurement of Occupational Eye and Thyroid Radiation Doses in Pediatric Interventional Cardiologists at a Tertiary Hospital

被引:3
|
作者
Khafaji, Mawya [1 ]
Ashour, Tariq M. [2 ]
Mozahim, Naif F. [2 ]
Tashkandi, Abdullah [2 ]
Alqarni, Basil [2 ]
Malaikah, Abdulrahman A. [2 ]
Bagabas, Abdulaziz K. [2 ]
Alwasabi, Abdullah A. [2 ]
Albahiti, Sarah K. [1 ]
机构
[1] King Abdulaziz Univ, Fac Med, Radiol Dept, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Fac Med, Jeddah, Saudi Arabia
关键词
thyroid dose; eye lens dose; staff exposure; intervention pediatric cardiology; occupational radiation dose; cardiac catheterization; STAFF; EXTREMITIES; EXPOSURE; SCATTER;
D O I
10.7759/cureus.44894
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Advances in imaging techniques have led to increased utilization of imaging devices in catheterization laboratories. Invasive surgical procedures for cardiac disorders have been largely replaced by fluoroscopic cardiac catheterization. With this increase, concerns and risks associated with exposure to ionizing radiation among interventional cardiologists are growing. This study aims to measure and compare the occupational doses to the eye lens and thyroid of pediatric interventional cardiologists during different procedures in the catheterization laboratory and its significance. Methodology In this study, cardiologists wore bandanas with attached dosimeters to measure the absorbed doses to the eyes and thyroid gland. The dosimeters were collected for reading. The procedure types were also collected. In addition, the total fluoroscopy time and tube voltage of the biplane machine were measured. SPSS version 23 (IBM Corp., Armonk, NY, USA) was used to analyze the data. The characteristics of the study sample were described using simple counts and percentages, whereas means and standard deviations were used for continuous variables. Statistical significance was set at p-values <0.05. Results A total of 93 procedures were evaluated. The mean absorbed doses for all 93 procedures in both eyes and thyroid were 0.09 mGy and 0.08 mGy, respectively. A significant difference was found between the left and right eye measurements (p = 0.034), with higher doses administered to the left eye. However, no significant difference was observed between the right and left thyroid doses (p = 0.281). Significant correlations were found between the eye and thyroid doses and the procedure type (p = 0.02 and p = 0.009, respectively). Conclusions A significant amount of radiation was measured in the measurements of both organs. In addition, radiation dose measurements varied between different types of procedures. Our current results indicate the importance and necessity of applying the radiation protection concept of dose optimization.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Occupational radiation dose to the eye lens of physicians from departments of interventional radiology
    Lian, Meng-En
    Tsai, Yuan-Hsiung
    Li, I-Gung
    Hong, Yu-Han
    Chang, Szu-Li
    Tsai, Hui-Yu
    RADIATION MEASUREMENTS, 2020, 132
  • [42] Radiation exposure of interventional cardiologists during coronary angiography: evaluation by phantom measurement and computer simulation
    Roh, Younghoon
    Nam, Sora
    Lee, Bong-Ki
    Ryu, Dong-Ryeol
    Chun, Kwangjin
    Lee, Kyu-Sun
    Cho, Namho
    Yoon, Yongsu
    Park, Hyemin
    Cho, Byung-Ryul
    Kim, Jung Su
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (04) : 1279 - 1287
  • [43] Radiation exposure of interventional cardiologists during coronary angiography: evaluation by phantom measurement and computer simulation
    Younghoon Roh
    Sora Nam
    Bong-Ki Lee
    Dong-Ryeol Ryu
    Kwangjin Chun
    Kyu-Sun Lee
    Namho Cho
    Yongsu Yoon
    Hyemin Park
    Byung-Ryul Cho
    Jung Su Kim
    Physical and Engineering Sciences in Medicine, 2020, 43 : 1279 - 1287
  • [44] Assessment of Occupational Radiation Doses in Different Diagnostic and Interventional Radiology and Molecular Imaging Services
    Bouchareb, Y.
    Al-Maskery, I.
    Al-Zeheimi, H.
    Al-Rasbi, A.
    Al-Makhmari, N.
    Al-Haji, A.
    Al-Dhuhli, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S851 - S851
  • [45] Influence of patient thickness and operation modes on occupational and patient radiation doses in interventional cardiology
    Vano, E.
    Gonzalez, L.
    Fernandez, J. M.
    Prieto, C.
    Guibelalde, E.
    RADIATION PROTECTION DOSIMETRY, 2006, 118 (03) : 325 - 330
  • [46] Occupational radiation doses in interventional cardiology:: a 15-year follow-up
    Vaño, E
    Gonzalez, L
    Fernandez, JM
    Alfonso, F
    Macaya, C
    BRITISH JOURNAL OF RADIOLOGY, 2006, 79 (941): : 383 - 388
  • [47] RADIATION DOSES TO THE EYE LENS AND FOREHEAD OF INTERVENTIONAL RADIOLOGISTS: HOW HIGH AND ON WHAT GROUNDS?
    Psarras, M.
    Ploussi, A.
    Carinou, E.
    Brountzos, E.
    Spiliopoulos, S. C.
    Palialexis, K.
    Kelekis, A.
    Filippiadis, D.
    Seimenis, I.
    Efstathopoulos, E. P.
    RADIATION PROTECTION DOSIMETRY, 2020, 190 (02) : 150 - 157
  • [48] Occupational Exposure of the Eye Lens in Interventional Procedures: How to Assess and Manage Radiation Dose
    Ciraj-Bjelac, Olivera
    Carinou, Eleftheria
    Ferrari, Paolo
    Gingaume, Merce
    Merce, Marta Sans
    O'Connor, Una
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2016, 13 (11) : 1347 - 1353
  • [49] Validation of ELDO approaches for retrospective assessment of cumulative eye lens doses of interventional cardiologists-results from DoReMi project
    Domienik, J.
    Farah, J.
    Struelens, L.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : 736 - 745
  • [50] Radiation dose levels during interventional cardiology procedures in a tertiary care hospital
    Dragusin, O
    Desmet, W
    Heidbuchel, H
    Padovani, R
    Bosmans, H
    RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 231 - 235