摘要
Occupational radiation doses in interventional radiology can potentially be high. Therefore, reliable methods to assess the effective dose are needed. In the present work, the relationship between the personal dose equivalent, Hp(10), the reading of a personal dosimeter and the effective dose of the radiologist were studied using Monte Carlo simulations. In particular, the protection provided by a lead apron was investigated. Emphasis was placed on sensitivity of the results to changes in irradiation conditions. In our simulations a 0.35 mm thick lead apron and thyroid shield reduced the effective dose, on average, by a factor of 27 (the range of these data was 15-41). Without the thyroid shield the average reduction factor was 15 (range 6-22). The reduction sensitively depended on the projection and the X-ray tube voltage. The dosimeter reading, when the dosimeter was worn above the apron and a thyroid shield was used, overestimated the effective dose on average by a factor of 130 (range 44258) when the dosimeter was located on the breast closest to the primary X-ray beam. Without the thyroid shield the average overestimation was 69 (range 32-127). If the dosimeter was worn under the apron its reading generally underestimated the effective dose (on average by 20% with the thyroid shield). Our study indicates that, even though large variations are present, the often used conversion coefficient from the dosimeter reading above the apron to the effective dose, around 1/30, generally overestimates the effective dose by a factor of two or more.
引用
收藏
页码:460 / 468
页数:9
相关论文
共 50 条
  • [1] Occupational radiation doses in interventional radiology: Simulations
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 36 - 38
  • [2] A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations
    Abdelrahman, Mahmoud
    Lombardo, Pasquale
    Camp, Anna
    Duch, Maria A.
    Phillips, Christophe
    Seret, Alain
    Vanhavere, Filip
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 58 - 70
  • [3] Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations
    Koukorava, C.
    Carinou, E.
    Ferrari, P.
    Krim, S.
    Struelens, L.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1216 - 1222
  • [4] Calculation of Radiation Doses to Patients Undergoing Interventional Procedures by Monte Carlo Simulations
    Nam, H. W.
    Lee, M. J.
    Na, H. J.
    Kim, K. P.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E517 - E517
  • [5] Fast Monte Carlo codes for occupational dosimetry in interventional radiology
    Garcia Balcaza, V
    Camp, A.
    Badal, A.
    Andersson, M.
    Almen, A.
    Ginjaume, M.
    Duch, M. A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 85 : 166 - 174
  • [6] Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures
    Efstathopoulos, E. P.
    Pantos, I.
    Andreou, M.
    Gkatzis, A.
    Carinou, E.
    Koukorava, C.
    Kelekis, N. L.
    Brountzos, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (997): : 70 - 77
  • [7] Monte Carlo calculations for reporting patient organ doses from interventional radiology
    Huo, Wanli
    Feng, Mang
    Pit, Yifei
    Chen, Zhi
    Gao, Yiming
    Xu, X. George
    [J]. ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [8] Managing occupational doses with smartphones in interventional radiology
    Sanchez, Roberto M.
    Fernandez, Daniel
    Vano, Eliseo
    Fernandez, Jose M.
    [J]. MEDICAL PHYSICS, 2021, 48 (10) : 5830 - 5836
  • [9] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [10] Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses
    Koukorava, C.
    Farah, J.
    Struelens, L.
    Clairand, I.
    Donadille, L.
    Vanhavere, F.
    Dimitriou, P.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (03) : 509 - 528