Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses

被引:82
|
作者
Koukorava, C. [1 ,2 ]
Farah, J. [3 ]
Struelens, L. [4 ]
Clairand, I. [3 ]
Donadille, L. [3 ]
Vanhavere, F. [4 ]
Dimitriou, P. [2 ]
机构
[1] Greek Atom Energy Commiss, Div Licensing & Inspect, Athens 15310, Greece
[2] Univ Athens, Sch Med, Dept Med Phys, GR-11527 Athens, Greece
[3] Inst Radioprotect & Surete Nucl, Human Hlth Div, F-92262 Fontenay Aux Roses, France
[4] Belgian Nucl Res Ctr, Dept Radiat Protect Dosimetry & Calibrat, BE-2400 Mol, Belgium
关键词
ORAMED PROJECT; EXPOSURE; CARDIOLOGISTS; EXTREMITY; STAFF; PERSONNEL; DOSIMETRY; CATARACT; EYEWEAR; HANDS;
D O I
10.1088/0952-4746/34/3/509
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Monte Carlo calculations were used to investigate the efficiency of radiation protection equipment in reducing eye and whole body doses during fluoroscopically guided interventional procedures. Eye lens doses were determined considering different models of eyewear with various shapes, sizes and lead thickness. The origin of scattered radiation reaching the eyes was also assessed to explain the variation in the protection efficiency of the different eyewear models with exposure conditions. The work also investigates the variation of eye and whole body doses with ceiling-suspended shields of various shapes and positioning. For all simulations, a broad spectrum of configurations typical for most interventional procedures was considered. Calculations showed that 'wrap around' glasses are the most efficient eyewear models reducing, on average, the dose by 74% and 21% for the left and right eyes respectively. The air gap between the glasses and the eyes was found to be the primary source of scattered radiation reaching the eyes. The ceiling-suspended screens were more efficient when positioned close to the patient's skin and to the x-ray field. With the use of such shields, the H-p(10) values recorded at the collar, chest and waist level and the H-p(3) values for both eyes were reduced on average by 47%, 37%, 20% and 56% respectively. Finally, simulations proved that beam quality and lead thickness have little influence on eye dose while beam projection, the position and head orientation of the operator as well as the distance between the image detector and the patient are key parameters affecting eye and whole body doses.
引用
收藏
页码:509 / 528
页数:20
相关论文
共 30 条
  • [1] OCCUPATIONAL EYE LENS DOSE ESTIMATED USING WHOLE-BODY DOSEMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY: A MONTE CARLO STUDY
    Bozovic, Predrag
    Ciraj-Bjelac, Olivera
    Petrovic, Jelena Stankovic
    [J]. RADIATION PROTECTION DOSIMETRY, 2019, 185 (02) : 135 - 142
  • [2] Influences of operator head posture and protective eyewear on eye lens doses in interventional radiology: A Monte Carlo Study
    Mao, Li
    Liu, Tianyu
    Caracappa, Peter F.
    Lin, Hui
    Gao, Yiming
    Dauer, Lawrence T.
    Xu, X. George
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : 2744 - 2751
  • [3] Monte Carlo simulations of occupational radiation doses in interventional radiology
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 460 - 468
  • [4] UTILIZING MONTE CARLO SIMULATIONS IN ESTIMATION OF OCCUPATIONAL EYE LENS DOSE BASED ON WHOLE BODY DOSIMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY
    Bozovic, Predrag M.
    Ciraj-Bjelac, Olivera F.
    Stankovic Petrovic, Jelena S.
    Arandjic, Danijela D.
    Ceklic, Sandra M.
    [J]. NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2018, 33 (04): : 375 - 379
  • [5] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [6] The use of personal protection equipment for the absorbed doses of eye lens and thyroid gland in CBCT exams using Monte Carlo
    Soares, Maria Rosangela
    Santos, William S.
    Neves, Lucio P.
    Perini, Ana P.
    Batista, Wilson O. G.
    Maia, Ana F.
    Belinato, Walmir
    Caldas, Linda V. E.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 167
  • [7] MONTE CARLO CALCULATIONS ON EXTREMITY AND EYE LENS DOSIMETRY FOR MEDICAL STAFF AT INTERVENTIONAL RADIOLOGY PROCEDURES
    Carinou, E.
    Ferrari, P.
    Koukorava, C.
    Krim, S.
    Struelens, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 492 - 496
  • [8] Study of the parameters affecting operator doses in interventional radiology using Monte Carlo simulations
    Koukorava, C.
    Carinou, E.
    Ferrari, P.
    Krim, S.
    Struelens, L.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1216 - 1222
  • [9] ASSESSMENT OF WHOLE BODY, SKIN AND EYE LENS DOSES OF THE INTERVENTIONAL RADIOLOGISTS AT SELECTED HOSPITALS IN IRAN
    Danaei, Z.
    Pooya, S. M. Hosseini
    Gharehbagh, E. Jazayeri
    Baradaran, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 170 - 175
  • [10] A parametric study of occupational radiation dose in interventional radiology by Monte-Carlo simulations
    Abdelrahman, Mahmoud
    Lombardo, Pasquale
    Camp, Anna
    Duch, Maria A.
    Phillips, Christophe
    Seret, Alain
    Vanhavere, Filip