ASSESSMENT OF WHOLE BODY, SKIN AND EYE LENS DOSES OF THE INTERVENTIONAL RADIOLOGISTS AT SELECTED HOSPITALS IN IRAN

被引:2
|
作者
Danaei, Z. [1 ]
Pooya, S. M. Hosseini [2 ]
Gharehbagh, E. Jazayeri [1 ]
Baradaran, S. [2 ,3 ]
机构
[1] Univ Tehran Med Sci, Sch Allied Med, Dept Technol Radiol & Radiotherapy, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Tehran, Iran
[3] Iran Nucl Regulatory Author, Tehran, Iran
关键词
MEDICAL STAFF; EXPOSURE; FLUOROSCOPY; EQUIVALENT; DOSIMETRY;
D O I
10.1093/rpd/ncab036
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High radiation doses to the body may lead to the stochastic/deterministic effects of ionizing radiation on the critical organs as well as causing the cataract in eye lens of the clinical staff in interventional radiology. In this study, the received doses of the eyes, skin and whole body of 38 clinical staff including physicians, residents, nurses and radiotechnologists in cardiac angiography departments in three selected hospitals were assessed using personal dosemeters during two bimonthly dosimetry periods. Moreover, the correlation coefficients among the measured dose components including eye lens dose, skin dose and whole body dose equivalent in both area of under and over their lead-apron were calculated for all these occupational groups. The results show that the occupational annual dose values of the clinical staff are below the annual dose limits recommended by International Commission on Radiation Protection. Furthermore, among the measured dose components, the highest correlation coefficient value was obtained between the eye lens dose and personal dose equivalent measured over the lead apron for all the occupational groups.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
  • [1] Local skin and eye lens equivalent doses in interventional neuroradiology
    Michael Sandborg
    Sandro Rossitti
    Håkan Pettersson
    [J]. European Radiology, 2010, 20 : 725 - 733
  • [2] Local skin and eye lens equivalent doses in interventional neuroradiology
    Sandborg, Michael
    Rossitti, Sandro
    Pettersson, Hakan
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (03) : 725 - 733
  • [3] Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staff
    Martin, C. J.
    Magee, J. S.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (02) : 445 - 460
  • [4] RADIATION DOSES TO THE EYE LENS AND FOREHEAD OF INTERVENTIONAL RADIOLOGISTS: HOW HIGH AND ON WHAT GROUNDS?
    Psarras, M.
    Ploussi, A.
    Carinou, E.
    Brountzos, E.
    Spiliopoulos, S. C.
    Palialexis, K.
    Kelekis, A.
    Filippiadis, D.
    Seimenis, I.
    Efstathopoulos, E. P.
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 190 (02) : 150 - 157
  • [5] Ratios of Eye Lens and Hand Equivalent Doses with Whole-Body Effective Doses for Operators Performing Interventional Radiological Procedures
    Tsai, Wan-Chih
    Chu, Wei-Han
    Sheu, Rong-Jiun
    [J]. HEALTH PHYSICS, 2022, 123 (03): : 257 - 264
  • [6] ASSESSMENT OF EYE LENS DOSES FOR WORKERS DURING INTERVENTIONAL RADIOLOGY PROCEDURES
    Urboniene, A.
    Sadzeviciene, E.
    Ziliukas, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 299 - 303
  • [7] ASSESSMENT OF EYE LENS DOSES IN INTERVENTIONAL RADIOLOGY: A SIMULATION IN LABORATORY CONDITIONS
    Cemusova, Z.
    Ekendahl, D.
    Judas, L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 256 - 260
  • [8] EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS
    Yokoyama, Sumi
    Suzuki, Shoichi
    Toyama, Hiroshi
    Arakawa, Shinji
    Inoue, Satoshi
    Kinomura, Yutaka
    Kobayashi, Ikuo
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 218 - 222
  • [9] Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses
    Koukorava, C.
    Farah, J.
    Struelens, L.
    Clairand, I.
    Donadille, L.
    Vanhavere, F.
    Dimitriou, P.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (03) : 509 - 528
  • [10] CORRELATION OF EYE LENS DOSES AND PERSONAL DOSE EQUIVALENT MEASURED ON THE ARM OF INTERVENTIONAL CARDIOLOGISTS FOR A RETROSPECTIVE ASSESSMENT OF DOSES TO OPERATORS' EYE LENS
    Domienik-Andrzejewska, Joanna
    Brodecki, Marcin
    Zmyslony, Marek
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 189 (03) : 271 - 278