CORRELATION OF EYE LENS DOSES AND PERSONAL DOSE EQUIVALENT MEASURED ON THE ARM OF INTERVENTIONAL CARDIOLOGISTS FOR A RETROSPECTIVE ASSESSMENT OF DOSES TO OPERATORS' EYE LENS

被引:3
|
作者
Domienik-Andrzejewska, Joanna [1 ]
Brodecki, Marcin [1 ]
Zmyslony, Marek [1 ]
机构
[1] Nofer Inst Occupat Med, Radiat Protect Dept, 8 St Teresa Str, PL-91348 Lodz, Poland
关键词
RADIOLOGY; RADIATION;
D O I
10.1093/rpd/ncaa039
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Coefficients converting the readings of the whole body dosemeter worn on the left arm to eye lens doses were determined by analysing the correlations between H-p(10) and H-p(3) values. Doses were measured on a phantom for specific C-arm projections typically used during CA/PCI procedures. In order to estimate the cumulative eye lens doses, conversion coefficients were then applied to the dose records of interventional cardiologists collected in the database of dosimetry service between the years 1995 and 2009. The H-p(10) to H-p(3) conversion coefficients are 0.29 (CV = 34%) and 0.17 (CV = 42%) for left and right eye lens, respectively. However, they can vary from one laboratory to another depending on working technique. From among 61 interventional cardiologists, none exceeded the threshold dose of 0.5 Gy for eye lens opacities. However, 44% of interventional cardiologists were likely to exceed the annual limit of 20 mSv for the most exposed eye at least once in the analysed time period.
引用
收藏
页码:271 / 278
页数:8
相关论文
共 50 条
  • [1] A correlation study of eye lens dose and personal dose equivalent for interventional cardiologists
    Farah, J.
    Struelens, L.
    Dabin, J.
    Koukorava, C.
    Donadille, L.
    Jacob, S.
    Schnelzer, M.
    Auvinen, A.
    Vanhavere, F.
    Clairand, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (04) : 561 - 569
  • [2] EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS
    Yokoyama, Sumi
    Suzuki, Shoichi
    Toyama, Hiroshi
    Arakawa, Shinji
    Inoue, Satoshi
    Kinomura, Yutaka
    Kobayashi, Ikuo
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 218 - 222
  • [3] Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses
    Jacob, Sophie
    Donadille, Laurent
    Maccia, Carlo
    Bar, Olivier
    Boveda, Serge
    Laurier, Dominique
    Bernier, Marie-Odile
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 153 (03) : 282 - 293
  • [4] Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens Doses
    Struelens, L.
    Dabin, J.
    Carinou, E.
    Askounis, P.
    Ciraj-Bjelac, O.
    Domienik-Andrzejewska, J.
    Berus, D.
    Padovani, R.
    Farah, J.
    Covens, P.
    [J]. RADIATION RESEARCH, 2018, 189 (04) : 399 - 408
  • [5] Estimation of eye lens doses received by pediatric interventional cardiologists
    Alejo, L.
    Koren, C.
    Ferrer, C.
    Corredoira, E.
    Serrada, A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2015, 103 : 43 - 47
  • [6] Local skin and eye lens equivalent doses in interventional neuroradiology
    Michael Sandborg
    Sandro Rossitti
    Håkan Pettersson
    [J]. European Radiology, 2010, 20 : 725 - 733
  • [7] Local skin and eye lens equivalent doses in interventional neuroradiology
    Sandborg, Michael
    Rossitti, Sandro
    Pettersson, Hakan
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (03) : 725 - 733
  • [8] Correlation between eye lens doses and over apron doses in interventional procedures
    Gracia-Ochoa, M.
    Candela-Juan, C.
    Vilar-Palop, J.
    Ruiz Rodriguez, J. C.
    Soriano Cruz, A.
    Palma Copete, J. D.
    Pujades Claumarchirant, M. C.
    Llorca Domaica, N.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 10 - 17
  • [9] Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists
    Farah, J.
    Struelens, L.
    Auvinen, A.
    Jacob, S.
    Koukorava, C.
    Schnelzer, M.
    Vanhavere, F.
    Clairand, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 84 - 88
  • [10] Validation of ELDO approaches for retrospective assessment of cumulative eye lens doses of interventional cardiologists-results from DoReMi project
    Domienik, J.
    Farah, J.
    Struelens, L.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : 736 - 745