Estimation of eye lens doses received by pediatric interventional cardiologists

被引:4
|
作者
Alejo, L. [1 ]
Koren, C. [1 ]
Ferrer, C. [1 ]
Corredoira, E. [1 ]
Serrada, A. [1 ]
机构
[1] Hosp Univ La Paz, Dept Med Phys, Madrid 28046, Spain
关键词
Eye lens dose; Pediatric interventional cardiology; Optically stimulated luminescence; dosimetry; DOSIMETRY;
D O I
10.1016/j.apradiso.2015.05.008
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Maximum H-p(0.07) dose to the eye lens received in a year by the pediatric interventional cardiologists has been estimated. Optically stimulated luminescence dosimeters were placed on the eyes of an anthropomorphic phantom, whose position in the room simulates the most common irradiation conditions. Maximum workload was considered with data collected from procedures performed in the Hospital. None of the maximum values obtained exceed the dose limit of 20 mSv recommended by ICRP. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:43 / 47
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF EYE LENS DOSES OF INTERVENTIONAL CARDIOLOGISTS
    Yokoyama, Sumi
    Suzuki, Shoichi
    Toyama, Hiroshi
    Arakawa, Shinji
    Inoue, Satoshi
    Kinomura, Yutaka
    Kobayashi, Ikuo
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 218 - 222
  • [2] Estimation of cardiologists radiation doses received during interventional examinations
    Bor, D.
    Onal, E.
    Olgar, T.
    Caglan, A.
    Toklu, T.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2211 - 2212
  • [3] Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists
    Farah, J.
    Struelens, L.
    Auvinen, A.
    Jacob, S.
    Koukorava, C.
    Schnelzer, M.
    Vanhavere, F.
    Clairand, I.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 164 (1-2) : 84 - 88
  • [4] Eye lens radiation exposure to interventional cardiologists: a retrospective assessment of cumulative doses
    Jacob, Sophie
    Donadille, Laurent
    Maccia, Carlo
    Bar, Olivier
    Boveda, Serge
    Laurier, Dominique
    Bernier, Marie-Odile
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 153 (03) : 282 - 293
  • [5] Eye Lens Doses Received by Radiation Workers in Interventional Medical Procedures
    Hiswara, E.
    Kartikasari, D.
    Sofyan, H.
    Nuraeni, N.
    Sandy, Kyp
    [J]. ATOM INDONESIA, 2020, 46 (03) : 135 - 140
  • [6] CORRELATION OF EYE LENS DOSES AND PERSONAL DOSE EQUIVALENT MEASURED ON THE ARM OF INTERVENTIONAL CARDIOLOGISTS FOR A RETROSPECTIVE ASSESSMENT OF DOSES TO OPERATORS' EYE LENS
    Domienik-Andrzejewska, Joanna
    Brodecki, Marcin
    Zmyslony, Marek
    [J]. RADIATION PROTECTION DOSIMETRY, 2020, 189 (03) : 271 - 278
  • [7] Measurement of Occupational Eye and Thyroid Radiation Doses in Pediatric Interventional Cardiologists at a Tertiary Hospital
    Khafaji, Mawya
    Ashour, Tariq M.
    Mozahim, Naif F.
    Tashkandi, Abdullah
    Alqarni, Basil
    Malaikah, Abdulrahman A.
    Bagabas, Abdulaziz K.
    Alwasabi, Abdullah A.
    Albahiti, Sarah K.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [8] Radiation-Induced Lens Opacities among Interventional Cardiologists: Retrospective Assessment of Cumulative Eye Lens Doses
    Struelens, L.
    Dabin, J.
    Carinou, E.
    Askounis, P.
    Ciraj-Bjelac, O.
    Domienik-Andrzejewska, J.
    Berus, D.
    Padovani, R.
    Farah, J.
    Covens, P.
    [J]. RADIATION RESEARCH, 2018, 189 (04) : 399 - 408
  • [9] Effectiveness of pelvic lead blanket to reduce the doses to eye lens and hands of interventional cardiologists and assistant nurses
    Grabowicz, W.
    Domienik-Andrzejewska, J.
    Masiarek, K.
    Gornik, T.
    Grycewicz, T.
    Brodecki, M.
    Lubinski, A.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2017, 37 (03) : 715 - 727
  • [10] Track, calculate and optimise eye lens doses of interventional cardiologists using mEyeDose and mEyeDose_X
    Covens, P.
    Dabin, J.
    De Troyer, O.
    Dragusin, O.
    Maushagen, J.
    Struelens, L.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 678 - 687