Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures

被引:111
|
作者
Efstathopoulos, E. P. [1 ]
Pantos, I. [1 ]
Andreou, M. [1 ]
Gkatzis, A. [1 ]
Carinou, E. [2 ]
Koukorava, C. [2 ]
Kelekis, N. L. [1 ]
Brountzos, E. [1 ]
机构
[1] Univ Athens, Dept Radiol 2, Sch Med, GR-12462 Athens, Greece
[2] GAEC, Aghia Paraskevi, Greece
来源
BRITISH JOURNAL OF RADIOLOGY | 2011年 / 84卷 / 997期
关键词
SURGICAL PLACEMENT; STAFF DOSIMETRY; MEDICAL STAFF; PATIENT; EXPOSURE; CATHETERS; HANDS;
D O I
10.1259/bjr/83222759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. Methods: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. Results: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 mu Sv, maximum 5239 mu Sv) and left finger (average 324 mu Sv, maximum 2877 mu Sv), whereas lower doses were recorded for the legs (average 124 mu Sv, maximum 1959 mu Sv) and the eyes (average 64 mu Sv, maximum 1129 mu Sv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 mu Sv, maximum 41 mu Sv) and legs (average 18 mu Sv, maximum 22 mu Sv), whereas doses to the eyes were minimal (average 4 mu Sv, maximum 16 mu Sv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 mu Sv/1000 cGy cm(2) and KAP was poorly correlated to the interventionists' extremity doses. Conclusion: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [1] Radiation exposure in interventional cardiology: extremities doses
    El Hassane, Cyrine
    Ben Ali, Abdelhai
    Bendaoud, Nabil
    Boushaki, Ghania Medkour Ishak
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (18) : 2238 - 2243
  • [2] Staff radiation doses to the lower extremities in interventional radiology
    Shortt, C. P.
    Al-Hashimi, H.
    Malone, L.
    Lee, M. J.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (06) : 1206 - 1209
  • [3] Assessment of occupational radiation doses to eye lens during interventional radiology procedures
    Ali, Amir
    Al-Nuaimi, Meshari
    Khan, Banaras
    Burki, Shamsullah
    Nishtar, Tahira
    Yaseen, Muhammad
    Shah, Syed Sher Azam
    Irfan, Muhammad
    RADIATION PHYSICS AND CHEMISTRY, 2024, 225
  • [4] Staff Radiation Doses to the Lower Extremities in Interventional Radiology
    C. P. Shortt
    H. Al-Hashimi
    L. Malone
    M. J. Lee
    CardioVascular and Interventional Radiology, 2007, 30 : 1206 - 1209
  • [5] Radiation doses in paediatric interventional cardiology procedures
    Tsapaki, Virginia
    Kottou, Sofia
    Korniotis, Sarantis
    Nikolaki, Niki
    Rammos, Spyridon
    Apostolopoulou, Sotiria C.
    RADIATION PROTECTION DOSIMETRY, 2008, 132 (04) : 390 - 394
  • [6] Patient Radiation Doses in Interventional Cardiology Procedures
    Pantos, Ioannis
    Patatoukas, Georgios
    Katritsis, Demosthenes G.
    Efstathopoulos, Efstathios
    CURRENT CARDIOLOGY REVIEWS, 2009, 5 (01) : 1 - 11
  • [7] Occupational radiation doses in interventional radiology: Simulations
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) : 36 - 38
  • [8] Occupational radiation doses during interventional procedures
    Nuraeni, N.
    Hiswara, E.
    Kartikasari, D.
    Waris, A.
    Haryanto, F.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [9] Patient radiation doses in paediatric interventional cardiology procedures: a review
    Harbron, R. W.
    Dreuil, S.
    Bernier, M-O
    Pearce, M. S.
    Thierry-Chef, I.
    Chapple, C-L
    Baysson, H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : R131 - R144
  • [10] Monte Carlo simulations of occupational radiation doses in interventional radiology
    Siiskonen, T.
    Tapiovaara, M.
    Kosunen, A.
    Lehtinen, M.
    Vartiainen, E.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (954): : 460 - 468