Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures

被引:111
|
作者
Efstathopoulos, E. P. [1 ]
Pantos, I. [1 ]
Andreou, M. [1 ]
Gkatzis, A. [1 ]
Carinou, E. [2 ]
Koukorava, C. [2 ]
Kelekis, N. L. [1 ]
Brountzos, E. [1 ]
机构
[1] Univ Athens, Dept Radiol 2, Sch Med, GR-12462 Athens, Greece
[2] GAEC, Aghia Paraskevi, Greece
来源
BRITISH JOURNAL OF RADIOLOGY | 2011年 / 84卷 / 997期
关键词
SURGICAL PLACEMENT; STAFF DOSIMETRY; MEDICAL STAFF; PATIENT; EXPOSURE; CATHETERS; HANDS;
D O I
10.1259/bjr/83222759
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to determine occupational dose levels in interventional radiology and cardiology procedures. Methods: The study covered a sample of 25 procedures and monitored occupational dose for all laboratory personnel. Each individual wore eight thermoluminescent dosemeters next to the eyes, wrists, fingers and legs during each procedure. Radiation protection shields used in each procedure were recorded. Results: The highest doses per procedure were recorded for interventionists at the left wrist (average 485 mu Sv, maximum 5239 mu Sv) and left finger (average 324 mu Sv, maximum 2877 mu Sv), whereas lower doses were recorded for the legs (average 124 mu Sv, maximum 1959 mu Sv) and the eyes (average 64 mu Sv, maximum 1129 mu Sv). Doses to the assisting nurses during the intervention were considerably lower; the highest doses were recorded at the wrists (average 26 mu Sv, maximum 41 mu Sv) and legs (average 18 mu Sv, maximum 22 mu Sv), whereas doses to the eyes were minimal (average 4 mu Sv, maximum 16 mu Sv). Occupational doses normalised to kerma area product (KAP) ranged from 11.9 to 117.3 mu Sv/1000 cGy cm(2) and KAP was poorly correlated to the interventionists' extremity doses. Conclusion: Calculation of the dose burden for interventionists considering the actual number of procedures performed annually revealed that dose limits for the extremities and the lenses of the eyes were not exceeded. However, there are cases in which high doses have been recorded and this can lead to exceeding the dose limits when bad practices are followed and the radiation protection tools are not properly used.
引用
收藏
页码:70 / 77
页数:8
相关论文
共 50 条
  • [31] EXTREMITY AND EYE LENS DOSES OF INTERVENTIONAL RADIOLOGY AND CARDIOLOGY WORKERS
    Urboniene, Ausra
    Griciene, Birute
    MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 109 - 111
  • [32] Patients radiation doses analysis in a contemporary cohort of patients undergoing interventional radiology procedures
    Nogales, J. M.
    Ordiales, J. M.
    Martinez-Naharro, A.
    Yuste-Dominguez, M.
    Sanchez-Giralt, S.
    Lopez-Minguez, J. R.
    Gonzalez-Fernandez, R.
    Martinez-Caceres, G.
    Merchan-Herrera, A.
    Diaz-Cortegana, F.
    EUROPEAN HEART JOURNAL, 2012, 33 : 242 - 242
  • [33] Patient Radiation Doses in Interventional Radiology Procedures: Comparison of Fluoroscopy Dose Indices between the American College of Radiology Dose Index Registry-Fluoroscopy Pilot and the Radiation Doses in Interventional Radiology Study
    Jones, A. Kyle
    Wunderle, Kevin A.
    Fruscello, Tom
    Simanowith, Michael
    Cline, Brendan
    Dharmadhikari, Shalmali
    Duan, Xinhui
    Durack, Jeremy C.
    Hirschl, David
    Kim, Don-Soo
    Mahmood, Usman
    Mann, Steve D.
    Martin, Charles
    Metwalli, Zeyad
    Moirano, Jeffrey M.
    Neill, Rebecca A.
    Newsome, Janice
    Padua, Horacio
    Schoenfeld, Alan H.
    Miller, Donald L.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2023, 34 (04)
  • [34] Recommendations for occupational radiation protection in interventional cardiology
    Duran, Ariel
    Hian, Sim Kui
    Miller, Donald L.
    Le Heron, John
    Padovani, Renato
    Vano, Eliseo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (01) : 29 - 42
  • [35] Evaluation of patients' and occupational radiation risk dose during conventional and interventional radiology procedures
    Tamam, Nissren
    Salah, H.
    Almogren, Kholoud S.
    Mahgoub, Omer
    Saeed, Mohammed Khalil
    Abdullah, Yousef
    Tai, Duong Thanh
    Omer, Hiba
    Sulieman, Abdelmoneim
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 207
  • [36] Informed Consent for Radiation in Interventional Radiology Procedures
    Zener, Rebecca
    Johnson, Peter
    Wiseman, Daniele
    Pandey, Sachin
    Mujoomdar, Amol
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2018, 69 (01): : 30 - 37
  • [37] Occupational and Patient Doses in Interventional Cardiology in Indonesia: A Preliminary Result
    Hiswara, E.
    Ng, K. H.
    Sofyan, H.
    Kartikasari, D.
    Nuraeni, N.
    ATOM INDONESIA, 2019, 45 (01) : 37 - 41
  • [38] OCCUPATIONAL EXPOSURE DOSES IN INTERVENTIONAL PROCEDURES IN BOSNIA AND HERZEGOVINA
    Basic, B.
    Beganovic, A.
    Skopljak-Beganovic, A.
    Samek, D.
    RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 501 - 504
  • [39] Reference levels and patient doses in interventional cardiology procedures in Greece
    George Simantirakis
    Christina Koukorava
    Maria Kalathaki
    Christos Pafilis
    Ioannis Kaisas
    Sotirios Economides
    Costas J. Hourdakis
    Vassiliki Kamenopoulou
    Evaggelos Georgiou
    European Radiology, 2013, 23 : 2324 - 2332
  • [40] Reference levels and patient doses in interventional cardiology procedures in Greece
    Simantirakis, George
    Koukorava, Christina
    Kalathaki, Maria
    Pafilis, Christos
    Kaisas, Ioannis
    Economides, Sotirios
    Hourdakis, Costas J.
    Kamenopoulou, Vassiliki
    Georgiou, Evaggelos
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2324 - 2332