Synergistic combination of natural deep eutectic solvent and chemical vapor generation for trace determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry

被引:6
|
作者
Abellan-Martin, Sergio J. [1 ,2 ]
Perez, Jorge [1 ,2 ]
Pinheiro, Fernanda C. [3 ]
Nobrega, Joaquim A. [4 ]
Aguirre, Miguel Angel [1 ,2 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Analyt Chem & Food Sci, Fac Sci, POB 99, Alicante 03080, Spain
[2] Univ Alicante, Univ Inst Mat, Fac Sci, POB 99, Alicante 03080, Spain
[3] Univ Fed Minas Gerais, Dept Chem, ICEX, Ave Antonio Carlos, 6627, BR-31270901 Belo Horizonte, MG, Brazil
[4] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13560970 Sao Carlos, SP, Brazil
来源
关键词
Pharmaceutical samples; Microwave-assisted digestion; Dispersive liquid-liquid microextraction; Natural deep eutectic solvent; Multinebulizer; Chemical vapor generation; LIQUID-LIQUID MICROEXTRACTION; HYDRIDE GENERATION; IMPURITIES; CADMIUM; MERCURY; SE;
D O I
10.1016/j.sampre.2023.100084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and environmentally friendly analytical method for simultaneous determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. In order to increase the sensitivity of the analysis, a multinebulizer has been used for chemical vapor generation (CVG) after a dispersive liquid-liquid microextraction (DLLME) procedure using a natural deep eutectic solvent (NADES) as extractant solvent. The factors affecting analyte extraction and on-line chemical vapor generation have been optimized by multivariate analysis. Under optimized conditions, DLLME-CVG-ICP OES improved limit of quantitation (LOQ) values on average 50-fold higher compared with direct ICP OES analysis and afforded an increase of the sensitivity (i.e., enrichment factor) on average 25-times higher than those obtained with CVG-ICP OES analysis. According to the United States Pharmacopoeia (USP) Chapter 232, it means LOQ values are on average 4.3-times lower than their respective 0.3J values for the target-elements from class 1. Trueness has been evaluated by recovery experiments following USP recommendations for two oral drug samples in solid dosage form (i.e., commercial dosage tablets). In addition, the greenness of the developed method has been evaluated using the AGREEprep metrics, showing an excellent green character since it includes the miniaturization of the sample preparation procedure using a reduced volume (i.e., few microliters) of a non-hazardous extractant solvent for multielemental analysis.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Determination of As, Cd and Hg in emulsified vegetable oil by flow injection chemical vapour generation inductively coupled plasma mass spectrometry
    Chang, Yu-Tzu
    Jiang, Shiuh-Jen
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (01) : 140 - 144
  • [42] Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk
    Niedobová, Eva
    Machát, Jiří
    Otruba, Vítězslav
    Kanický, Viktor
    Journal of Analytical Atomic Spectrometry, 2005, 20 (09): : 945 - 949
  • [43] Determination of selenium by flow injection hydride generation inductively coupled plasma optical emission spectrometry
    Hernandez, Princess C.
    Tyson, Julian F.
    Uden, Peter C.
    Yates, Dennis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (03) : 298 - 304
  • [44] Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk
    Niedobová, E
    Machát, J
    Otruba, V
    Kanicky, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (09) : 945 - 949
  • [45] Determination of inorganic mercury in petroleum production water by inductively coupled plasma optical emission spectrometry following photochemical vapor generation
    Francisco, Barbara Bruna A.
    Rocha, Anderson A.
    Grinberg, Patricia
    Sturgeon, Ralph E.
    Cassella, Ricardo J.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (03) : 751 - 758
  • [46] SIMULTANEOUS DETERMINATION OF TRACE-ELEMENTS IN SHELLS BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY
    HIRANO, M
    ONUMA, N
    MASUDA, F
    BUNSEKI KAGAKU, 1979, 28 (05) : 313 - 318
  • [47] Trace Metal Determination in the Medicinal Plant Hyoscyamus (Solanaceae) by Inductively Coupled Plasma Optical Emission Spectrometry
    Keskin, Cumali
    Kisin, Erdener
    Yavuz, Murat
    ATOMIC SPECTROSCOPY, 2014, 35 (05) : 193 - 199
  • [48] Trace determination of Hg together with As, Sb, Se by miniaturized optical emission spectrometry integrated with chemical vapor generation and capacitively coupled argon microwave miniplasma discharge
    Matusiewicz, Henryk
    Slachcinski, Mariusz
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 : 52 - 59
  • [49] Dispersive liquid-liquid microextraction based on deep eutectic solvent for elemental impurities determination in oral and parenteral drugs by inductively coupled plasma optical emission spectrometry
    Pinheiro, Fernanda C.
    Aguirre, Miguel Angel
    Nobrega, Joaquim A.
    Gonzalez-Gallardo, Nerea
    Ramon, Diego J.
    Canals, Antonio
    ANALYTICA CHIMICA ACTA, 2021, 1185
  • [50] Nano Platinum-Catalyzed Dry Ashing of Flour Samples for the Determination of Trace Metals by Inductively Coupled Plasma Optical Emission Spectrometry
    Sahayam, A. C.
    Venkateswarlu, G.
    Chaurasia, S. C.
    ATOMIC SPECTROSCOPY, 2009, 30 (04) : 139 - 142