Synergistic combination of natural deep eutectic solvent and chemical vapor generation for trace determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry

被引:6
|
作者
Abellan-Martin, Sergio J. [1 ,2 ]
Perez, Jorge [1 ,2 ]
Pinheiro, Fernanda C. [3 ]
Nobrega, Joaquim A. [4 ]
Aguirre, Miguel Angel [1 ,2 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Analyt Chem & Food Sci, Fac Sci, POB 99, Alicante 03080, Spain
[2] Univ Alicante, Univ Inst Mat, Fac Sci, POB 99, Alicante 03080, Spain
[3] Univ Fed Minas Gerais, Dept Chem, ICEX, Ave Antonio Carlos, 6627, BR-31270901 Belo Horizonte, MG, Brazil
[4] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13560970 Sao Carlos, SP, Brazil
来源
关键词
Pharmaceutical samples; Microwave-assisted digestion; Dispersive liquid-liquid microextraction; Natural deep eutectic solvent; Multinebulizer; Chemical vapor generation; LIQUID-LIQUID MICROEXTRACTION; HYDRIDE GENERATION; IMPURITIES; CADMIUM; MERCURY; SE;
D O I
10.1016/j.sampre.2023.100084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and environmentally friendly analytical method for simultaneous determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. In order to increase the sensitivity of the analysis, a multinebulizer has been used for chemical vapor generation (CVG) after a dispersive liquid-liquid microextraction (DLLME) procedure using a natural deep eutectic solvent (NADES) as extractant solvent. The factors affecting analyte extraction and on-line chemical vapor generation have been optimized by multivariate analysis. Under optimized conditions, DLLME-CVG-ICP OES improved limit of quantitation (LOQ) values on average 50-fold higher compared with direct ICP OES analysis and afforded an increase of the sensitivity (i.e., enrichment factor) on average 25-times higher than those obtained with CVG-ICP OES analysis. According to the United States Pharmacopoeia (USP) Chapter 232, it means LOQ values are on average 4.3-times lower than their respective 0.3J values for the target-elements from class 1. Trueness has been evaluated by recovery experiments following USP recommendations for two oral drug samples in solid dosage form (i.e., commercial dosage tablets). In addition, the greenness of the developed method has been evaluated using the AGREEprep metrics, showing an excellent green character since it includes the miniaturization of the sample preparation procedure using a reduced volume (i.e., few microliters) of a non-hazardous extractant solvent for multielemental analysis.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] DETERMINATION OF TRACE THALLIUM IN NATURAL-WATERS BY INDUCTIVELY COUPLED PLASMA EMISSION-SPECTROMETRY COMBINED WITH SOLVENT-EXTRACTION
    MIYAZAKI, A
    SANPEI, T
    TAO, H
    NAGASE, T
    NIPPON KAGAKU KAISHI, 1992, (03) : 307 - 311
  • [32] DETERMINATION OF TRACE-ELEMENTS IN PLANT MATERIALS BY INDUCTIVELY COUPLED PLASMA OPTICAL EMISSION SPECTROMETRY
    SCOTT, RH
    STRASHEIM, A
    ANALYTICA CHIMICA ACTA, 1975, 76 (01) : 71 - 78
  • [33] Solution cathode glow discharge induced vapor generation of iodine for determination by inductively coupled plasma optical emission spectrometry
    Zhu, Zhenli
    He, Qian
    Shuai, Qin
    Zheng, Hongtao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (09) : 1390 - 1394
  • [34] Determination of trace metals in urine by direct dilution Inductively Coupled Plasma Optical Emission Spectrometry
    Meza-Figueroa, D.
    Cebrian, M.
    Lopez-Carrillo, L.
    Ostrosky-Wegman, P.
    Torres-Sanchez, L.
    Caldero-Aranda, E.
    EPIDEMIOLOGY, 2008, 19 (01) : S226 - S226
  • [36] High-efficiency photooxidation vapor generation of osmium for determination by inductively coupled plasma-optical emission spectrometry
    Zhu, Zhenli
    He, Dong
    Huang, Chunying
    Zheng, Hongtao
    Zhang, Suicheng
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (03) : 506 - 511
  • [37] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    Anil, G.
    Reddy, M. R. P.
    Prakash, T. L.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 61 (07) : 641 - 643
  • [38] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    Anil, G.
    Reddy, M.R.P.
    Prakash, T.L.
    Journal of Analytical Chemistry, 2006, 61 (07): : 641 - 643
  • [39] Determination of trace impurities in tantalum powder and its compounds by inductively coupled plasma optical emission spectrometry using solvent extraction
    G. Anil
    M. R. P. Reddy
    T. L. Prakash
    Journal of Analytical Chemistry, 2006, 61 : 641 - 643
  • [40] Fast Determination of Trace Elemental Sulfur Residue in Rare Earth Sulfide Samples by Inductively Coupled Plasma Optical Emission Spectrometry
    Ma, Yuanyuan
    Liu, Pingping
    Hu, Xiaohui
    Ning, Jiagui
    Li, Chengyu
    Duan, Taicheng
    ATOMIC SPECTROSCOPY, 2020, 41 (02) : 81 - 86