Synergistic combination of natural deep eutectic solvent and chemical vapor generation for trace determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry

被引:6
|
作者
Abellan-Martin, Sergio J. [1 ,2 ]
Perez, Jorge [1 ,2 ]
Pinheiro, Fernanda C. [3 ]
Nobrega, Joaquim A. [4 ]
Aguirre, Miguel Angel [1 ,2 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Analyt Chem & Food Sci, Fac Sci, POB 99, Alicante 03080, Spain
[2] Univ Alicante, Univ Inst Mat, Fac Sci, POB 99, Alicante 03080, Spain
[3] Univ Fed Minas Gerais, Dept Chem, ICEX, Ave Antonio Carlos, 6627, BR-31270901 Belo Horizonte, MG, Brazil
[4] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, POB 676, BR-13560970 Sao Carlos, SP, Brazil
来源
关键词
Pharmaceutical samples; Microwave-assisted digestion; Dispersive liquid-liquid microextraction; Natural deep eutectic solvent; Multinebulizer; Chemical vapor generation; LIQUID-LIQUID MICROEXTRACTION; HYDRIDE GENERATION; IMPURITIES; CADMIUM; MERCURY; SE;
D O I
10.1016/j.sampre.2023.100084
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new and environmentally friendly analytical method for simultaneous determination of As, Cd, Hg and Pb in drug samples by inductively coupled plasma optical emission spectrometry (ICP OES) has been developed. In order to increase the sensitivity of the analysis, a multinebulizer has been used for chemical vapor generation (CVG) after a dispersive liquid-liquid microextraction (DLLME) procedure using a natural deep eutectic solvent (NADES) as extractant solvent. The factors affecting analyte extraction and on-line chemical vapor generation have been optimized by multivariate analysis. Under optimized conditions, DLLME-CVG-ICP OES improved limit of quantitation (LOQ) values on average 50-fold higher compared with direct ICP OES analysis and afforded an increase of the sensitivity (i.e., enrichment factor) on average 25-times higher than those obtained with CVG-ICP OES analysis. According to the United States Pharmacopoeia (USP) Chapter 232, it means LOQ values are on average 4.3-times lower than their respective 0.3J values for the target-elements from class 1. Trueness has been evaluated by recovery experiments following USP recommendations for two oral drug samples in solid dosage form (i.e., commercial dosage tablets). In addition, the greenness of the developed method has been evaluated using the AGREEprep metrics, showing an excellent green character since it includes the miniaturization of the sample preparation procedure using a reduced volume (i.e., few microliters) of a non-hazardous extractant solvent for multielemental analysis.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Determination of trace elements in refined gold samples by inductively coupled plasma atomic emission spectrometry
    Steharnik, Mirjana
    Todorovic, Marija
    Manojlovic, Dragan
    Stankovic, Dalibor
    Mutic, Jelena
    Trujic, Vlastimir
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (04) : 565 - 577
  • [22] Natural mineral assisted photochemical vapor generation for determination of trace inorganic arsenic by inductively coupled plasma mass spectrometry
    Bao, Haolin
    Peng, Xiuhong
    Song, Zelin
    Ning, Yongyan
    Yu, Ying
    Gao, Ying
    MICROCHEMICAL JOURNAL, 2021, 170
  • [23] Preparation of urine samples for trace metal determination: a study with aluminium analysis by inductively coupled plasma optical emission spectrometry
    Burden, TJ
    Whitehead, MW
    Thompson, RPH
    Powell, JJ
    ANNALS OF CLINICAL BIOCHEMISTRY, 1998, 35 : 245 - 253
  • [24] Determination of Pb in lipsticks by flow injection chemical vapor generation isotope dilution inductively coupled plasma mass spectrometry
    Chen, Wei-Ni
    Jiang, Shiuh-Jen
    Chen, Yen-Ling
    Sahayam, A. C.
    MICROCHEMICAL JOURNAL, 2015, 119 : 128 - 132
  • [25] Determination of Se in biological samples by axial view inductively coupled plasma optical emission spectrometry after digestion with aqua regia and on-line chemical vapor generation
    dos Santos, Eder Jose
    Herrmann, Amanda Beatriz
    de Caires, Suzete Kulik
    Azzolin Frescura, Vera Lucia
    Curtius, Adilson Jose
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (06) : 549 - 553
  • [26] Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry for the Determination of Cr, Cd, Hg, and Pb in Honeys
    Li, Yue-Ting
    Jiang, Shiuh-Jen
    Sahayam, A. C.
    FOOD ANALYTICAL METHODS, 2017, 10 (02) : 434 - 441
  • [27] Determination of trace metal ions in Gentiana rigescens by inductively coupled plasma-optical emission spectrometry after deep eutectic solvent-based digestion and related pharmacodynamic evaluation
    Yang, Xiaofang
    Yan, Caixia
    Zhang, Rui
    Sun, Yiping
    Li, Zhengui
    Liu, Yong
    Yang, Shengchun
    Shen, Lei
    Wen, Xiaodong
    ANALYTICA CHIMICA ACTA, 2022, 1221
  • [28] Electrothermal Vaporization Inductively Coupled Plasma Mass Spectrometry for the Determination of Cr, Cd, Hg, and Pb in Honeys
    Yue-Ting Li
    Shiuh-Jen Jiang
    A.C. Sahayam
    Food Analytical Methods, 2017, 10 : 434 - 441
  • [29] Evaluation of vapor generation for the determination of nickel by inductively coupled plasma-atomic emission spectrometry
    Marrero, J
    Smichowski, P
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (02) : 196 - 202
  • [30] Evaluation of vapor generation for the determination of nickel by inductively coupled plasma-atomic emission spectrometry
    Julieta Marrero
    Patricia Smichowski
    Analytical and Bioanalytical Chemistry, 2002, 374 : 196 - 202