Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk

被引:29
|
作者
Niedobová, E [1 ]
Machát, J [1 ]
Otruba, V [1 ]
Kanicky, V [1 ]
机构
[1] Masaryk Univ, Lab Atom Spectrochem, Fac Sci, Brno 61137, Czech Republic
关键词
D O I
10.1039/b504525h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Vapour generation inductively coupled plasma optical emission spectrometry (VG-ICP-OES) was used for the determination of the iodine content in milk samples. Modified alkaline ashing of the milk sample was employed for the total digestion of organic matrix constituents. A mixture of potassium hydroxide ( 2 mL, 2 mol L-1 in ethanol) and calcium nitrate ( 2 mL, 0.4 mol L-1 in ethanol) was used in the digestion step as an ashing aid for 2 ml of milk sample ( or 200 mg of milk powder). Sample ash was then treated with hydrochloric acid ( 1.5 mL, 5 mol L-1) and sodium sulfite (1.25 mL, 1 mol L-1) for the elimination of carbonates, which would otherwise cause spectral interference. The vapour of elemental iodine was generated by means of oxidation of iodide by hydrogen peroxide ( 1 mol L-1) in sulfuric acid ( 5 mol L-1). Using a gas phase separator, matrix elements were completely eliminated; thus the spectral interference of phosphorus (178.222 nm) was removed and the most intense analytical line of iodine (178.218 nm) could be used for determination. The accuracy of the method was verified by analysis of CRM Non-Fat Milk Powder 1549 from NIST, as well as by the comparative study of VG-ICP-OES and ICP-MS results after alkaline solubilization ( TMAH 2.5 mL, 10%). The limit of detection for the VG-ICP-OES method is 20 mg L-1 for original milk samples ( based on 3 sigma of blank value). The concentration of iodine in real milk samples was found in the range 0.2 - 0.8 mg L-1 with a precision of determination from 0.5 to 3.5% ( 3 replicates).
引用
收藏
页码:945 / 949
页数:5
相关论文
共 50 条
  • [1] Vapour generation inductively coupled plasma optical emission spectrometry in determination of total iodine in milk
    Niedobová, Eva
    Machát, Jiří
    Otruba, Vítězslav
    Kanický, Viktor
    Journal of Analytical Atomic Spectrometry, 2005, 20 (09): : 945 - 949
  • [2] Determination of free and total sulfur dioxide in wine samples by vapour-generation inductively coupled plasma–optical-emission spectrometry
    Jiří Čmelík
    Jiří Machát
    Eva Niedobová
    Vítězslav Otruba
    Viktor Kanický
    Analytical and Bioanalytical Chemistry, 2005, 383 : 483 - 488
  • [3] Determination of free and total sulfur dioxide in wine samples by vapour-generation inductively coupled plasma-optical-emission spectrometry
    Cmelík, J
    Machát, J
    Niedobová, E
    Otruba, V
    Kanicky, V
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (03) : 483 - 488
  • [4] Determination of total iodine in soils by inductively coupled plasma mass spectrometry
    Yamada, H
    Kiriyama, T
    Yonebayashi, K
    SOIL SCIENCE AND PLANT NUTRITION, 1996, 42 (04) : 859 - 866
  • [5] Solution cathode glow discharge induced vapor generation of iodine for determination by inductively coupled plasma optical emission spectrometry
    Zhu, Zhenli
    He, Qian
    Shuai, Qin
    Zheng, Hongtao
    Hu, Shenghong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (09) : 1390 - 1394
  • [6] DETERMINATION OF MINERAL ELEMENTS IN MILK PRODUCTS BY INDUCTIVELY COUPLED PLASMA-OPTICAL EMISSION SPECTROMETRY
    Khan, Naeem
    Choi, Ji Yeon
    Nho, Eun Yeong
    Hwang, In Min
    Habte, Girum
    Khan, Murad Ali
    Park, Kyung Su
    Kim, Kyong Su
    ANALYTICAL LETTERS, 2014, 47 (09) : 1606 - 1613
  • [7] Determination of selenium by flow injection hydride generation inductively coupled plasma optical emission spectrometry
    Hernandez, Princess C.
    Tyson, Julian F.
    Uden, Peter C.
    Yates, Dennis
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (03) : 298 - 304
  • [8] Determination of Rhodium by Inductively Coupled Plasma Atomic Emission Spectrometry With Chemical Vapour Generation Sample Introduction Technique
    Duan Xu-chuan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (03) : 421 - 424
  • [9] REVIEW: Iodine Determination by Inductively Coupled Plasma Spectrometry
    Oliveira, Adriana A.
    Trevizan, Lilian C.
    Nobrega, Joaquim A.
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (06) : 447 - 473
  • [10] Determination of chalcophile elements in sulfide-bearing rocks by hydride generation inductively coupled plasma optical emission spectrometry and inductively coupled plasma mass spectrometry
    Seregina, I. F.
    Ognev, V. E.
    Sedykh, E. M.
    Kolotov, V. P.
    Krivolutskaya, N. A.
    Bolshov, M. A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 166 (166)