Comparison of voltammetric methods used in the interrogation of electrochemical aptamer-based sensors

被引:6
|
作者
Verrinder, Elsi [1 ,4 ]
Leung, Kaylyn K. [1 ,4 ]
Erdal, Murat Kaan [5 ]
Sepunaru, Lior [1 ,2 ]
Plaxco, Kevin W. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Biomol Sci & Engn Grad Program, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biol Engn Grad Program, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[5] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
来源
SENSORS & DIAGNOSTICS | 2024年 / 3卷 / 01期
基金
美国国家卫生研究院;
关键词
RESOLVED MOLECULAR MEASUREMENTS; POLAROGRAPHY; REAGENTLESS;
D O I
10.1039/d3sd00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (EAB) sensors are the first continuous molecular measurement technology that is both (1) able to function in situ in the living body and (2) independent of the chemical reactivity of its targets, rendering it generalizable to a wide range of analytes. Comprised of an electrode-bound, redox-reporter-modified aptamer, signal generation in EAB sensors arises when binding to this target-recognizing aptamer causes a conformation change that, in turn, alters the rate of electron transfer to and from the redox reporter to the electrode surface. A range of electrochemical approaches, including both voltammetric (e.g., cyclic, square wave, and alternating current voltammetry) and non-voltammetric (e.g., chronoamperometry, electrochemical phase interrogation) methods have been used to monitor this change in transfer rate, with square wave voltammetry having dominated recent reports. To date, however, the literature has seen few direct comparisons of the performance of these various approaches. In response we describe here comparisons of EAB sensors interrogated using square wave, differential pulse, and alternating current voltammetry. We find that, while the noise associated with AC voltammetry (in vitro in 37 degrees C whole blood) is exceptionally low, neither this approach nor differential pulse voltammetry support accurate drift correction under these same conditions, suggesting that neither approach is suitable for deployment in vivo. Square wave voltammetry, in contrast, matches or surpasses the gain achieved by the other two approaches, achieves good signal-to-noise, and supports high-accuracy drift correction in 37 degrees C whole blood. Taken together, these results finally confirm that square wave voltammetry is the preferred pulsed voltammetric method for interrogating EAB sensors in complex biological fluids. Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [21] In vivo pharmacokinetic measurements using electrochemical aptamer-based sensors
    Somerson, Jacob
    Plaxco, Kevin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [22] Immobilization Strategies for Enhancing Sensitivity of Electrochemical Aptamer-Based Sensors
    Liu, Yingzhu
    Canoura, Juan
    Alkhamis, Obtin
    Xiao, Yi
    ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (08) : 9491 - 9499
  • [23] Electronic aptamer-based sensors
    Willner, Itamar
    Zayats, Maya
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (34) : 6408 - 6418
  • [24] Electrochemical aptamer-based biosensors
    Kim, Yeon Seok
    Lee, Su Jin
    Gu, Man Bock
    BIOCHIP JOURNAL, 2008, 2 (03) : 175 - 182
  • [25] Recent Progress on Highly Selective and Sensitive Electrochemical Aptamer-based Sensors
    Tianwei Tang
    Yinghuan Liu
    Ying Jiang
    Chemical Research in Chinese Universities, 2022, 38 : 866 - 878
  • [26] Electrochemical, Electrochemiluminescence, and Photoelectrochemical Aptamer-Based Nanostructured Sensors for Biomarker Analysis
    Ravalli, Andrea
    Voccia, Diego
    Palchetti, Ilaria
    Marrazza, Giovanna
    BIOSENSORS-BASEL, 2016, 6 (03):
  • [27] Aptamer-Based Electrochemical Biosensors
    Lei Lihong
    Fu Yingchun
    Xu Xiahong
    Xie Qingji
    Yao Shouzhuo
    PROGRESS IN CHEMISTRY, 2009, 21 (04) : 724 - 731
  • [28] Using Spectroscopy to Guide the Adaptation of Aptamers into Electrochemical Aptamer-Based Sensors
    Wu, Yuyang
    Ranallo, Simona
    Del Grosso, Erica
    Chamoro-Garcia, Alejandro
    Ennis, Herbert L.
    Milosavic, Nenad
    Yang, Kyungae
    Kippin, Tod
    Ricci, Francesco
    Stojanovic, Milan
    Plaxco, Kevin W.
    BIOCONJUGATE CHEMISTRY, 2023, 34 (01) : 124 - 132
  • [29] Pulsed transistor operation enables miniaturization of electrochemical aptamer-based sensors
    Bidinger, Sophia L.
    Keene, Scott T.
    Han, Sanggil
    Plaxco, Kevin W.
    Malliaras, George G.
    Hasan, Tawfique
    SCIENCE ADVANCES, 2022, 8 (46)
  • [30] From the beaker to the body: translational challenges for electrochemical, aptamer-based sensors
    Arroyo-Curras, Netzahualcoyotl
    Dauphin-Ducharme, Philippe
    Scida, Karen
    Chavez, Jorge L.
    ANALYTICAL METHODS, 2020, 12 (10) : 1288 - 1310