Comparison of voltammetric methods used in the interrogation of electrochemical aptamer-based sensors

被引:6
|
作者
Verrinder, Elsi [1 ,4 ]
Leung, Kaylyn K. [1 ,4 ]
Erdal, Murat Kaan [5 ]
Sepunaru, Lior [1 ,2 ]
Plaxco, Kevin W. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Biomol Sci & Engn Grad Program, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biol Engn Grad Program, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[5] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
来源
SENSORS & DIAGNOSTICS | 2024年 / 3卷 / 01期
基金
美国国家卫生研究院;
关键词
RESOLVED MOLECULAR MEASUREMENTS; POLAROGRAPHY; REAGENTLESS;
D O I
10.1039/d3sd00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (EAB) sensors are the first continuous molecular measurement technology that is both (1) able to function in situ in the living body and (2) independent of the chemical reactivity of its targets, rendering it generalizable to a wide range of analytes. Comprised of an electrode-bound, redox-reporter-modified aptamer, signal generation in EAB sensors arises when binding to this target-recognizing aptamer causes a conformation change that, in turn, alters the rate of electron transfer to and from the redox reporter to the electrode surface. A range of electrochemical approaches, including both voltammetric (e.g., cyclic, square wave, and alternating current voltammetry) and non-voltammetric (e.g., chronoamperometry, electrochemical phase interrogation) methods have been used to monitor this change in transfer rate, with square wave voltammetry having dominated recent reports. To date, however, the literature has seen few direct comparisons of the performance of these various approaches. In response we describe here comparisons of EAB sensors interrogated using square wave, differential pulse, and alternating current voltammetry. We find that, while the noise associated with AC voltammetry (in vitro in 37 degrees C whole blood) is exceptionally low, neither this approach nor differential pulse voltammetry support accurate drift correction under these same conditions, suggesting that neither approach is suitable for deployment in vivo. Square wave voltammetry, in contrast, matches or surpasses the gain achieved by the other two approaches, achieves good signal-to-noise, and supports high-accuracy drift correction in 37 degrees C whole blood. Taken together, these results finally confirm that square wave voltammetry is the preferred pulsed voltammetric method for interrogating EAB sensors in complex biological fluids. Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [31] Recent Progress on Highly Selective and Sensitive Electrochemical Aptamer-based Sensors
    Tang Tianwei
    Liu Yinghuan
    Jiang Ying
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2022, 38 (04) : 866 - 878
  • [32] Biocompatible Hydrogel Membranes for the Protection of RNA Aptamer-Based Electrochemical Sensors
    Schoukroun-Barnes, Lauren R.
    Wagan, Samiullah
    Liu, Juan
    Leach, Jennie B.
    White, Ryan J.
    SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY X, 2013, 8719
  • [33] Aptamer-based Electrochemical Sensors for Rapid Detection of Veterinary Drug Residues
    Huang, Shiqiang
    Chen, Mingwen
    Xuan, Zhe
    Li, Shengbin
    Zhang, Mutang
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (05): : 4102 - 4116
  • [34] Optimization of Vancomycin Aptamer Sequence Length Increases the Sensitivity of Electrochemical, Aptamer-Based Sensors In Vivo
    Shaver, Alexander
    Mahlum, J. D.
    Scida, Karen
    Johnston, Melanie L.
    Pellitero, Miguel Aller
    Wu, Yao
    Carr, Gregory V.
    Arroyo-Curras, Netzahualcoyotl
    ACS SENSORS, 2022, 7 (12) : 3895 - 3905
  • [35] Aptamer-based electrochemical biosensor for label-free voltammetric detection of thrombin and adenosine
    Yan, Fangfang
    Wang, Fang
    Chen, Zilin
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 1380 - 1385
  • [36] Controlling Gold Morphology Using Electrodeposition for the Preparation of Electrochemical Aptamer-Based Sensors
    Ritz, Amanda J.
    Stuehr, Olivia M.
    Comer, Dante N.
    Lazenby, Robert A.
    ACS APPLIED BIO MATERIALS, 2024, 7 (03) : 1925 - 1935
  • [37] On the Signaling of Electrochemical Aptamer-Based Sensors: Collision- and Folding-Based Mechanisms
    Xiao, Yi
    Uzawa, Takanori
    White, Ryan J.
    DeMartini, Daniel
    Plaxco, Kevin W.
    ELECTROANALYSIS, 2009, 21 (11) : 1267 - 1271
  • [38] Aptamer-Based Electrochemical Sensing of Lysozyme
    Vasilescu, Alina
    Wang, Qian
    Li, Musen
    Boukherroub, Rabah
    Szunerits, Sabine
    CHEMOSENSORS, 2016, 4 (02)
  • [39] Switching the aptamer attachment geometry can dramatically alter the signalling and performance of electrochemical aptamer-based sensors
    Chamorro-Garcia, Alejandro
    Ortega, Gabriel
    Mariottini, Davide
    Green, Joshua
    Ricci, Francesco
    Plaxco, Kevin W.
    CHEMICAL COMMUNICATIONS, 2021, 57 (88) : 11693 - 11696
  • [40] Two kanamycin electrochemical aptamer-based sensors using different signal transduction mechanisms: A comparison of electrochemical behavior and sensing performance
    Han, Xianda
    Yu, Zhigang
    Li, Fengqin
    Shi, Wenbing
    Fu, Cuicui
    Yan, Hong
    Zhang, Guiling
    BIOELECTROCHEMISTRY, 2019, 129 : 270 - 277