Comparison of voltammetric methods used in the interrogation of electrochemical aptamer-based sensors

被引:6
|
作者
Verrinder, Elsi [1 ,4 ]
Leung, Kaylyn K. [1 ,4 ]
Erdal, Murat Kaan [5 ]
Sepunaru, Lior [1 ,2 ]
Plaxco, Kevin W. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Biomol Sci & Engn Grad Program, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biol Engn Grad Program, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[5] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
来源
SENSORS & DIAGNOSTICS | 2024年 / 3卷 / 01期
基金
美国国家卫生研究院;
关键词
RESOLVED MOLECULAR MEASUREMENTS; POLAROGRAPHY; REAGENTLESS;
D O I
10.1039/d3sd00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (EAB) sensors are the first continuous molecular measurement technology that is both (1) able to function in situ in the living body and (2) independent of the chemical reactivity of its targets, rendering it generalizable to a wide range of analytes. Comprised of an electrode-bound, redox-reporter-modified aptamer, signal generation in EAB sensors arises when binding to this target-recognizing aptamer causes a conformation change that, in turn, alters the rate of electron transfer to and from the redox reporter to the electrode surface. A range of electrochemical approaches, including both voltammetric (e.g., cyclic, square wave, and alternating current voltammetry) and non-voltammetric (e.g., chronoamperometry, electrochemical phase interrogation) methods have been used to monitor this change in transfer rate, with square wave voltammetry having dominated recent reports. To date, however, the literature has seen few direct comparisons of the performance of these various approaches. In response we describe here comparisons of EAB sensors interrogated using square wave, differential pulse, and alternating current voltammetry. We find that, while the noise associated with AC voltammetry (in vitro in 37 degrees C whole blood) is exceptionally low, neither this approach nor differential pulse voltammetry support accurate drift correction under these same conditions, suggesting that neither approach is suitable for deployment in vivo. Square wave voltammetry, in contrast, matches or surpasses the gain achieved by the other two approaches, achieves good signal-to-noise, and supports high-accuracy drift correction in 37 degrees C whole blood. Taken together, these results finally confirm that square wave voltammetry is the preferred pulsed voltammetric method for interrogating EAB sensors in complex biological fluids. Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [11] Heterogeneous and Homogeneous Aptamer-Based Electrochemical Sensors for Thrombin
    Tan, Emelyn S. Q.
    Wivanius, Ridha
    Toh, Chee-Seng
    ELECTROANALYSIS, 2009, 21 (06) : 749 - 754
  • [12] Solution-Phase Electrochemical Aptamer-Based Sensors
    Yuan, Yuchan
    Bali, Ahilya
    White, Ryan J.
    Heikenfeld, Jason
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (03) : 824 - 830
  • [13] Codeposition Enhances the Performance of Electrochemical Aptamer-Based Sensors
    Wu, Yuyang
    Shi, Jinyuan
    Kippin, Tod E.
    Plaxco, Kevin W.
    LANGMUIR, 2024, 40 (16) : 8703 - 8710
  • [14] Electrochemical aptamer-based sensors for the detection of heavy metals
    Ge, Shupan
    Ma, Xiaohua
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (09):
  • [15] Electrochemical Aptamer-Based Sensors with Tunable Detection Range
    Pan, Jing
    Xu, Wenxia
    Li, Wanlu
    Chen, Shuwen
    Dai, Yu
    Yu, Shanwu
    Zhou, Qitao
    Xia, Fan
    ANALYTICAL CHEMISTRY, 2023, 95 (01) : 420 - 432
  • [16] Aptamer-based electrochemical sensors with aptamer-complementary DNA oligonucleotides as probe
    Lu, Ying
    Li, Xianchan
    Zhang, Limin
    Yu, Ping
    Su, Lei
    Mao, Lanqun
    ANALYTICAL CHEMISTRY, 2008, 80 (06) : 1883 - 1890
  • [17] Research Progress in Electrochemical Aptamer-Based Sensors for Salmonella Detection
    Hao, Jinhua
    Gong, Ziqi
    Li, Min
    Yin, Jiaqi
    He, Jiaqi
    Li, Yanqing
    Zhang, Chunling
    Zhang, Min
    Shipin Kexue/Food Science, 2024, 45 (14): : 277 - 287
  • [18] Electrochemical aptamer-based sensors for food and water analysis: A review
    Li, Fengqin
    Yu, Zhigang
    Han, Xianda
    Lai, Rebecca Y.
    ANALYTICA CHIMICA ACTA, 2019, 1051 : 1 - 23
  • [19] Reagentless, Structure-Switching, Electrochemical Aptamer-Based Sensors
    Schoukroun-Barnes, Lauren R.
    Macazo, Florika C.
    Gutierrez, Brenda
    Lottermoser, Justine
    Liu, Juan
    White, Ryan J.
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 9, 2016, 9 : 163 - 181
  • [20] Nanoporous Gold for the Miniaturization of In Vivo Electrochemical Aptamer-Based Sensors
    Downs, Alex M.
    Gerson, Julian
    Hossain, M. Nur
    Ploense, Kyle
    Pham, Michael
    Kraatz, Heinz-Bernhard
    Kippin, Tod
    Plaxco, Kevin W.
    ACS SENSORS, 2021, 6 (06) : 2299 - 2306