Comparison of voltammetric methods used in the interrogation of electrochemical aptamer-based sensors

被引:6
|
作者
Verrinder, Elsi [1 ,4 ]
Leung, Kaylyn K. [1 ,4 ]
Erdal, Murat Kaan [5 ]
Sepunaru, Lior [1 ,2 ]
Plaxco, Kevin W. [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem & Biochem, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Biomol Sci & Engn Grad Program, Santa Barbara, CA 93106 USA
[3] Univ Calif Santa Barbara, Biol Engn Grad Program, Santa Barbara, CA 93106 USA
[4] Univ Calif Santa Barbara, Ctr Bioengn, Santa Barbara, CA 93106 USA
[5] Univ Calif Santa Barbara, Dept Elect & Comp Engn, Santa Barbara, CA 93106 USA
来源
SENSORS & DIAGNOSTICS | 2024年 / 3卷 / 01期
基金
美国国家卫生研究院;
关键词
RESOLVED MOLECULAR MEASUREMENTS; POLAROGRAPHY; REAGENTLESS;
D O I
10.1039/d3sd00083d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Electrochemical aptamer-based (EAB) sensors are the first continuous molecular measurement technology that is both (1) able to function in situ in the living body and (2) independent of the chemical reactivity of its targets, rendering it generalizable to a wide range of analytes. Comprised of an electrode-bound, redox-reporter-modified aptamer, signal generation in EAB sensors arises when binding to this target-recognizing aptamer causes a conformation change that, in turn, alters the rate of electron transfer to and from the redox reporter to the electrode surface. A range of electrochemical approaches, including both voltammetric (e.g., cyclic, square wave, and alternating current voltammetry) and non-voltammetric (e.g., chronoamperometry, electrochemical phase interrogation) methods have been used to monitor this change in transfer rate, with square wave voltammetry having dominated recent reports. To date, however, the literature has seen few direct comparisons of the performance of these various approaches. In response we describe here comparisons of EAB sensors interrogated using square wave, differential pulse, and alternating current voltammetry. We find that, while the noise associated with AC voltammetry (in vitro in 37 degrees C whole blood) is exceptionally low, neither this approach nor differential pulse voltammetry support accurate drift correction under these same conditions, suggesting that neither approach is suitable for deployment in vivo. Square wave voltammetry, in contrast, matches or surpasses the gain achieved by the other two approaches, achieves good signal-to-noise, and supports high-accuracy drift correction in 37 degrees C whole blood. Taken together, these results finally confirm that square wave voltammetry is the preferred pulsed voltammetric method for interrogating EAB sensors in complex biological fluids. Electrochemical aptamer-based sensors support real-time, in vivo molecular measurements. Here we compare the relative merits of square-wave, alternating current, and differential pulse voltammetry in the interrogation of such sensors.
引用
收藏
页码:95 / 103
页数:9
相关论文
共 50 条
  • [41] Determination of glyphosate using electrochemical aptamer-based label-free voltammetric biosensing platform
    Maghsoudi, Armin Salek
    Akmal, Milad Rezaei
    Mcclements, David Julian
    Sani, Mahmood Alizadeh
    Torabi, Raheleh
    Ataei, Mahshid
    Ganjali, Mohammad Reza
    Abdollahi, Mohammad
    Hassani, Shokoufeh
    MICROCHEMICAL JOURNAL, 2024, 203
  • [42] Recent Developments in Aptamer-Based Sensors for Diagnostics
    Sheraz, Muhammad
    Sun, Xiao-Feng
    Wang, Yongke
    Chen, Jiayi
    Sun, Le
    Sensors, 2024, 24 (23)
  • [43] Advanced aptamer-based sensors for monitoring theophylline
    Hartati, Yeni Wahyuni
    Zein, Muhammad Ihda H. L.
    Ibrahim, Abdullahi Umar
    Kharismasari, Clianta Yudin
    Syafira, Ratu Shifa
    Irkham
    Gunlazuardi, Jarnuzi
    Jiwanti, Prastika Krisma
    CLINICA CHIMICA ACTA, 2025, 571
  • [44] Aptamer-Based Sensors for Thrombin Detection Application
    Sun, Hongzhi
    Wang, Nannan
    Zhang, Lin
    Meng, Hongmin
    Li, Zhaohui
    CHEMOSENSORS, 2022, 10 (07)
  • [45] Electrochemical switching with a DNA aptamer-based electrochemical sensor
    Beiranvand, Shabnam
    Azadbakht, Azadeh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 76 : 925 - 933
  • [46] Aptamer-based sensors work in live animals
    Arnaud, Celia
    CHEMICAL & ENGINEERING NEWS, 2017, 95 (03) : 4 - 4
  • [47] Chronoamperometric interrogation of an electrochemical aptamer-based sensor with tetrahedral DNA nanostructure pendulums for continuous biomarker measurements
    Wang, Yizhou
    Duan, Haowei
    Yalikun, Yaxiaer
    Cheng, Shaokoon
    Li, Ming
    ANALYTICA CHIMICA ACTA, 2024, 1305
  • [48] A nanoporous electrochemical aptamer-based sensors for rapid detection of cardiac troponin I in blood
    Qin, Sai-Nan
    Nong, Yun-Chuan
    Cao, Chuan-Liang
    Chen, Li-Yang
    Cao, Yi-Jie
    Wan, Ting
    Feng, Lei
    Salminen, Kalle
    Sun, Jian-Jun
    Li, Ju
    TALANTA, 2025, 284
  • [49] Ferrocenyl Compounds as Alternative Redox Labels for Robust and Versatile Electrochemical Aptamer-Based Sensors
    Kim, Gyeongho
    Park, Soo Eun
    Lee, Woohyeong
    Joo, Jung Min
    Yang, Haesik
    ACS SENSORS, 2024, 9 (12): : 6450 - 6459
  • [50] Achieving Reproducible Performance of Electrochemical, Folding Aptamer-Based Sensors on Microelectrodes: Challenges and Prospects
    Liu, Juan
    Wagan, Samiullah
    Morris, Melissa Davila
    Taylor, James
    White, Ryan J.
    ANALYTICAL CHEMISTRY, 2014, 86 (22) : 11417 - 11424