Enhancing Patient-specific Quality Assurance in Carbon-ion Radiation Therapy: Recalculating Delivered Dose Distribution Using Log Data

被引:0
|
作者
Yun, Yongdo [1 ]
Han, Min cheol [1 ]
Kim, Changhwan [1 ]
Hong, Chae-Seon [1 ]
Kim, Dong wook [1 ]
Lee, Ho [1 ]
Kim, Hojin [1 ]
Han, Soorim [1 ]
Souda, Hikaru [2 ]
Lee, Sung hyun [3 ]
Miyasaka, Yuya [2 ]
Iwai, Takeo [2 ]
Kim, Jin sung [1 ,4 ]
机构
[1] Yonsei Univ, Coll Med, Heavy Ion Therapy Res Inst, Dept Radiat Oncol,Yonsei Canc Ctr, Seoul 03722, South Korea
[2] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[3] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
IN VIVO | 2025年 / 39卷 / 02期
关键词
Carbon-ion radiation therapy; log data; patient-specific quality assurance; treatment planning system; biological dose distribution;
D O I
10.21873/invivo.13913
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Log data from radiation treatment machines can play a crucial role in quality assurance by enabling the recalculation of the delivered dose distribution and identification of deviations in treatment delivery. This article proposes a novel method for recalculating the delivered dose distribution in carbon-ion radiation therapy using log data. Materials and Methods: The proposed approach leverages existing functionality in commercial treatment planning systems, thus eliminating the need for specialized in-house software for dose calculation and evaluation. The performed tests entail data generation from actual log files using the Digital Imaging and Communications in Medicine standard, biological dose calculations, and gamma evaluations. Results: The log-based approach demonstrated notable advantages, including improved time efficiency and the ability to calculate three-dimensional biological doses. By recalculating the delivered dose distributions, our method improves quality assurance accuracy in carbon-ion radiation therapy. It complements conventional measurement-based patient- specific quality assurance methods, serving as a valuable addition to the arsenal of tools available for treatment evaluation. Conclusion: We believe that our method has the potential to enhance the efficacy of patient-specific quality assurance and contribute significantly to the advancement of carbon-ion radiation therapy, thereby reinforcing the ongoing evolution of particle therapy.
引用
收藏
页码:1086 / 1093
页数:8
相关论文
共 50 条
  • [21] Patient-specific Quality Assurance Using a 4-dimensional Programmable Motion Platform in Respiratory Gated Radiation Therapy
    Lee, J.
    Park, Y.
    Sung, W.
    Kim, J.
    Choi, C.
    Ye, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S785 - S785
  • [22] Patient-specific dose verification and synchronization quality assurance tests for helical tornotherapy using film
    James, J
    Hui, S
    Mackie, T
    Fenwick, J
    MEDICAL PHYSICS, 2004, 31 (06) : 1845 - 1845
  • [23] Evaluation of Patient-Specific Quality Assurance for RapidArc Treatment Delivery Using Dose Volume Histogram
    Manna, Sumanta
    Singh, Benoy Kumar
    Das, K. J. Maria
    JOURNAL OF POLYMER & COMPOSITES, 2023, 11 : S14 - S22
  • [24] TomoEQA: Dose verification for patient-specific quality assurance in helical tomotherapy using an exit detector
    Han, Min Cheol
    Chang, Kyung Hwan
    Kim, Jihun
    Han, Su Chul
    Park, Kwangwoo
    Kim, Dong Wook
    Kim, Hojin
    Kim, Jin Sung
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 82 : 1 - 6
  • [25] Patient-specific quality assurance and plan dose errors on breast intensity-modulated proton therapy
    Liu, Chunbo
    Zheng, Dandan
    Bradley, Julie A.
    Vega, Raymond B. Mailhot
    Li, Zuofeng
    Mendenhall, Nancy P.
    Liang, Xiaoying
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 84 - 91
  • [26] A management method for the statistical results of patient-specific quality assurance for intensity-modulated radiation therapy
    Nakamura, Satoshi
    Okamoto, Hiroyuki
    Wakita, Akihisa
    Umezawa, Rei
    Takahashi, Kana
    Inaba, Koji
    Murakami, Naoya
    Kato, Toru
    Igaki, Hiroshi
    Ito, Yoshinori
    Abe, Yoshihisa
    Itami, Jun
    JOURNAL OF RADIATION RESEARCH, 2017, 58 (04) : 572 - 578
  • [27] Comparison of patient-specific intensity modulated radiation therapy quality assurance for the prostate across multiple institutions
    Kubo, Kazuki
    Monzen, Hajime
    Shimomura, Kohei
    Matsumoto, Kenji
    Sato, Tomoharu
    Tamura, Mikoto
    Nakamatsu, Kiyoshi
    Ishii, Kentaro
    Kawamorita, Ryu
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2019, 24 (06) : 600 - 605
  • [28] Effect of patient positioning on carbon-ion therapy planned dose distribution to pancreatic tumors and organs at risk
    Miki, Kentaro
    Fukahori, Mai
    Kumagai, Motoki
    Yamada, Shigeru
    Mori, Shinichiro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 33 : 38 - 46
  • [29] Prospective Clinical Validation of Virtual Patient-Specific Quality Assurance of Volumetric Modulated Arc Therapy Radiation Therapy Plans
    Wall, Phillip D. H.
    Hirata, Emily
    Morin, Olivier
    Valdes, Gilmer
    Witztum, Alon
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 113 (05): : 1091 - 1102
  • [30] Dosimetric validation of a GPU-based dose engine for a fast in silico patient-specific quality assurance program in light ion beam therapy
    Magro, Giuseppe
    Fassi, Martina
    Mirandola, Alfredo
    Rossi, Eleonora
    Molinelli, Silvia
    Russo, Stefania
    Bazani, Alessia
    Vai, Alessandro
    Ciocca, Mario
    Donetti, Marco
    Mairani, Andrea
    MEDICAL PHYSICS, 2022, 49 (12) : 7802 - 7814