Enhancing Patient-specific Quality Assurance in Carbon-ion Radiation Therapy: Recalculating Delivered Dose Distribution Using Log Data

被引:0
|
作者
Yun, Yongdo [1 ]
Han, Min cheol [1 ]
Kim, Changhwan [1 ]
Hong, Chae-Seon [1 ]
Kim, Dong wook [1 ]
Lee, Ho [1 ]
Kim, Hojin [1 ]
Han, Soorim [1 ]
Souda, Hikaru [2 ]
Lee, Sung hyun [3 ]
Miyasaka, Yuya [2 ]
Iwai, Takeo [2 ]
Kim, Jin sung [1 ,4 ]
机构
[1] Yonsei Univ, Coll Med, Heavy Ion Therapy Res Inst, Dept Radiat Oncol,Yonsei Canc Ctr, Seoul 03722, South Korea
[2] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[3] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
IN VIVO | 2025年 / 39卷 / 02期
关键词
Carbon-ion radiation therapy; log data; patient-specific quality assurance; treatment planning system; biological dose distribution;
D O I
10.21873/invivo.13913
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Log data from radiation treatment machines can play a crucial role in quality assurance by enabling the recalculation of the delivered dose distribution and identification of deviations in treatment delivery. This article proposes a novel method for recalculating the delivered dose distribution in carbon-ion radiation therapy using log data. Materials and Methods: The proposed approach leverages existing functionality in commercial treatment planning systems, thus eliminating the need for specialized in-house software for dose calculation and evaluation. The performed tests entail data generation from actual log files using the Digital Imaging and Communications in Medicine standard, biological dose calculations, and gamma evaluations. Results: The log-based approach demonstrated notable advantages, including improved time efficiency and the ability to calculate three-dimensional biological doses. By recalculating the delivered dose distributions, our method improves quality assurance accuracy in carbon-ion radiation therapy. It complements conventional measurement-based patient- specific quality assurance methods, serving as a valuable addition to the arsenal of tools available for treatment evaluation. Conclusion: We believe that our method has the potential to enhance the efficacy of patient-specific quality assurance and contribute significantly to the advancement of carbon-ion radiation therapy, thereby reinforcing the ongoing evolution of particle therapy.
引用
收藏
页码:1086 / 1093
页数:8
相关论文
共 50 条
  • [41] Machine Log File and Calibration Errors-based Patient-specific Quality Assurance (QA) for Volumetric Modulated Arc Therapy (VMAT)
    Ma, Yangguang
    Mou, Xuanqin
    Beeraka, Narasimha M.
    Guo, Yuexin
    Liu, Junqi
    Dai, Jianrong
    Fan, Ruitai
    CURRENT PHARMACEUTICAL DESIGN, 2023, 29 (34) : 2738 - 2751
  • [42] An Improved Statistical Model for Gamma Index Pass Rates in Intensity Modulated Radiation Therapy Patient-Specific Quality Assurance
    Jensen, P. James
    Donahue, William
    Chen, Zhe
    MEDICAL PHYSICS, 2021, 48 (06)
  • [43] Toward Safe Delivery of Radiation Therapy-Assessment of the Sensitivity of Clinically Used Patient-Specific Quality Assurance Methods
    Lehmann, Joerg
    Hussein, Mohammad
    Standen, Therese
    Siva, Shankar
    Moore, Alisha
    Subramanian, Brindha
    Barnes, Michael
    Greer, Peter
    Clark, Catharine
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2019, 15 : 23 - 23
  • [44] PATIENT-SPECIFIC QUALITY ASSURANCE FOR PROSTATE CANCER PATIENTS RECEIVING SPOT SCANNING PROTON THERAPY USING SINGLE-FIELD UNIFORM DOSE
    Zhu, X. Ronald
    Poenisch, Falk
    Song, Xiaofei
    Johnson, Jennifer L.
    Ciangaru, George
    Taylor, M. Brad
    Lii, MingFwu
    Martin, Craig
    Arjomandy, Bijan
    Lee, Andrew K.
    Choi, Seungtaek
    Quynh Nhu Nguyen
    Gillin, Michael T.
    Sahoo, Narayan
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : 552 - 559
  • [45] Evaluation of 4-Hz log files and secondary Monte Carlo dose calculation as patient-specific quality assurance for VMAT prostate plans
    Szeverinski, Philipp
    Kowatsch, Matthias
    Kunzler, Thomas
    Meinschad, Marco
    Clemens, Patrick
    DeVries, Alexander F.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (07): : 235 - 244
  • [46] Carbon-Ion Therapy Patient-Specific QA: Preliminary Results Derived Using 3D Polymer Gel Dosimetry in Anthropomorphic Inhomogeneous Geometry
    Vai, A.
    Magro, G.
    Kalaitzakis, G.
    Zourari, K.
    Makris, D. N.
    Pappas, E.
    Anemoni, L.
    Piazzola, M. E.
    Tampellini, S.
    Imparato, S.
    Ciocca, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : S141 - S141
  • [47] COMPARISON OF PATIENT-SPECIFIC QUALITY ASSURANCE RESULTS FROM A DELIVER-LOG BASED CALCULATION SYSTEM AND DOSE RECONSTRUCTION IN PATIENT ANATOMY BASED ON PHANTOM MEASUREMENTS
    Chan, Gordon
    Ostapiak, Orest
    Chow, Tom
    Liu, Baochang
    Wierzbicki, Marcin
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S136 - S136
  • [48] Dose Verification of 2D and 3D Intrafractional Tumor Motion for Patient-Specific Quality Assurance of Respiratory-Gated Radiation Therapy
    Lim, K.
    Lee, J.
    Park, Y.
    Park, J.
    Ye, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S700 - S700
  • [49] A patient-specific quality assurance study on absolute dose verification using ionization chambers of different volumes in RapidArc treatments
    Kumar, S. A. Syam
    Sukumar, Prabakar
    Sriram, Padmanaban
    Rajasekaran, Dhanabalan
    Aketi, Srinu
    Vivekanandan, Nagarajan
    MEDICAL DOSIMETRY, 2012, 37 (04) : 436 - 441
  • [50] Correlation between patient-specific quality assurance in volumetric modulated arc therapy and 2D dose image features
    Guo, Yixiao
    Hu, Jinyan
    Li, Yang
    Ran, Juntao
    Cai, Hongyi
    SCIENTIFIC REPORTS, 2023, 13 (01)