Enhancing Patient-specific Quality Assurance in Carbon-ion Radiation Therapy: Recalculating Delivered Dose Distribution Using Log Data

被引:0
|
作者
Yun, Yongdo [1 ]
Han, Min cheol [1 ]
Kim, Changhwan [1 ]
Hong, Chae-Seon [1 ]
Kim, Dong wook [1 ]
Lee, Ho [1 ]
Kim, Hojin [1 ]
Han, Soorim [1 ]
Souda, Hikaru [2 ]
Lee, Sung hyun [3 ]
Miyasaka, Yuya [2 ]
Iwai, Takeo [2 ]
Kim, Jin sung [1 ,4 ]
机构
[1] Yonsei Univ, Coll Med, Heavy Ion Therapy Res Inst, Dept Radiat Oncol,Yonsei Canc Ctr, Seoul 03722, South Korea
[2] Yamagata Univ, Grad Sch Med Sci, Dept Heavy Particle Med Sci, Yamagata, Japan
[3] Seoul Natl Univ, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[4] Oncosoft Inc, Seoul, South Korea
来源
IN VIVO | 2025年 / 39卷 / 02期
关键词
Carbon-ion radiation therapy; log data; patient-specific quality assurance; treatment planning system; biological dose distribution;
D O I
10.21873/invivo.13913
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background/Aim: Log data from radiation treatment machines can play a crucial role in quality assurance by enabling the recalculation of the delivered dose distribution and identification of deviations in treatment delivery. This article proposes a novel method for recalculating the delivered dose distribution in carbon-ion radiation therapy using log data. Materials and Methods: The proposed approach leverages existing functionality in commercial treatment planning systems, thus eliminating the need for specialized in-house software for dose calculation and evaluation. The performed tests entail data generation from actual log files using the Digital Imaging and Communications in Medicine standard, biological dose calculations, and gamma evaluations. Results: The log-based approach demonstrated notable advantages, including improved time efficiency and the ability to calculate three-dimensional biological doses. By recalculating the delivered dose distributions, our method improves quality assurance accuracy in carbon-ion radiation therapy. It complements conventional measurement-based patient- specific quality assurance methods, serving as a valuable addition to the arsenal of tools available for treatment evaluation. Conclusion: We believe that our method has the potential to enhance the efficacy of patient-specific quality assurance and contribute significantly to the advancement of carbon-ion radiation therapy, thereby reinforcing the ongoing evolution of particle therapy.
引用
收藏
页码:1086 / 1093
页数:8
相关论文
共 50 条
  • [31] A study to establish reasonable action limits for patient-specific quality assurance in intensity-modulated radiation therapy
    Both, Stefan
    Alecu, Ionut M.
    Stan, Andrada R.
    Alecu, Marius
    Ciura, Andrei
    Hansen, Jeremy M.
    Alecu, Rodica
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 1 - 8
  • [32] Trend lines on patient specific quality assurance in ion beam therapy with protons and carbon ions
    Schafasand, M.
    Kragl, G.
    Osorio, J.
    Vatnitsky, S.
    Stock, M.
    Carlino, A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S748 - S748
  • [33] Error detection using a convolutional neural network with dose difference maps in patient-specific quality assurance for volumetric modulated arc therapy
    Kimura, Yuto
    Kadoya, Noriyuki
    Tomori, Seiji
    Oku, Yohei
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 : 57 - 64
  • [34] Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
    Mancuso, Gordon M.
    Fontenot, Jonas D.
    Gibbons, John P.
    Parker, Brent C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4378 - 4385
  • [35] Virtual pretreatment patient-specific quality assurance of volumetric modulated arc therapy using deep learning
    Yoganathan, S. A.
    Ahmed, Sharib
    Paloor, Satheesh
    Torfeh, Tarraf
    Aouadi, Souha
    Al-Hammadi, Noora
    Hammoud, Rabih
    MEDICAL PHYSICS, 2023, 50 (12) : 7891 - 7903
  • [36] Using an Electronic Portal Imaging Device for Patient-Specific Volumetric Modulated Arc Therapy Quality Assurance
    Bakhtiari, M.
    Kumaraswamy, L.
    de Boer, S.
    Malhotra, H.
    Podgorsak, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3087 - +
  • [37] Treatment plan prescreening for patient-specific quality assurance measurements using independent Monte Carlo dose calculations
    Xu, Yuan
    Zhang, Ke
    Liu, Zhiqiang
    Liang, Bin
    Ma, Xiangyu
    Ren, Wenting
    Men, Kuo
    Dai, Jianrong
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [38] Therapeutic dose prediction using score-based diffusion model for pretreatment patient-specific quality assurance
    Yu, Xiuwen
    Lin, Jiabin
    Gong, Changfei
    Zhang, Minhui
    Luo, Xianyu
    Liu, Qiegen
    Zhang, Yun
    FRONTIERS IN ONCOLOGY, 2025, 14
  • [39] Applications of artificial intelligence for machine- and patient-specific quality assurance in radiation therapy: current status and future directions
    Ono, Tomohiro
    Iramina, Hiraku
    Hirashima, Hideaki
    Adachi, Takanori
    Nakamura, Mitsuhiro
    Mizowaki, Takashi
    JOURNAL OF RADIATION RESEARCH, 2024, 65 (04) : 421 - 432
  • [40] Development of an integrated patient-specific quality assurance program in radiation therapy: A pilot project by the gastrointestinal site group.
    Barrett, K
    Medlam, G
    Ditomasso, A
    Price, J
    Kelly, V
    Wong, R
    Warde, P
    Brierley, J
    Bissonnette, JP
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S155 - S155