Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT

被引:0
|
作者
Oechsner, Tim [1 ]
Soschynski, Martin [1 ]
Schlett, Christopher L. [1 ]
Krauss, Tobias [1 ]
Schupppert, Christopher [1 ]
Mueller-Peltzer, Katharina [1 ]
Vecsey-Nagy, Milan [3 ]
Kravchenko, Dmitrij [2 ,4 ]
Varga-Szemes, Akos
Emrich, Tilman [2 ,5 ]
Scheu, Raphael [6 ]
Taron, Jana [1 ]
Bamberg, Fabian [1 ]
Hagar, Muhammad Taha [1 ,2 ]
机构
[1] Univ Freiburg, Med Ctr, Fac Med, Dept Diagnost & Intervent Radiol, Freiburg, Germany
[2] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC USA
[3] Semmelweis Univ, Heart & Vasc Ctr, Budapest, Hungary
[4] Univ Hosp Bonn, Dept Diagnost & Intervent Radiol, Bonn, Germany
[5] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Diagnost & Intervent Radiol, Mainz, Germany
[6] Univ Cambridge, Sch Clin Med, Dept Publ Hlth & Primary Care, Cambridge, England
关键词
Aorta; CT; Photon-counting; Iodine; Contrast medium; COMPUTED-TOMOGRAPHY; CONTRAST MATERIAL; IMAGE QUALITY; ENERGY CT; RISK; MANAGEMENT;
D O I
10.1016/j.ejrad.2025.111919
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose. Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT. Images were acquired with fast pitch and full spectral capabilities (collimation 144 x 0.4 mm). The contrast protocol included a mixture of sodium chloride and iodinated contrast agent (Iopromide, total iodine dose: 9.5-9.8 g). Virtual monoenergetic images (VMIs) were reconstructed at 40, 50, 60, and 68 keV. Two blinded radiologists evaluated image quality on a 4-point scale. Attenuation was measured across eight regions in the aorta and iliac arteries, and contrast-to-noise ratio (CNR) was calculated. Statistical comparisons were performed using repeated measures ANOVA and Bonferroni post-hoc tests. Results: The final cohort consisted of 39 subjects (mean age: 69.6 +/- 9.6 years; 30.8 % female). VMI at 40 keV provided significantly higher attenuation: 478 +/- 114 HU, compared to 50 keV (331 +/- 74 HU), 60 keV (241 +/- 51 HU), and 68 keV (190 +/- 48 HU) (p < 0.01). This translated in increased CNR for 40 keV reconstructions (11.8 +/- 3.9), followed by 50 keV (9.1 +/- 3.0), 60 keV (7.0 +/- 2.3), and 68 keV (6.1 +/- 1.9) (p < 0.01). Subjective image quality was rated excellent at 40 keV (4 [3,4]), though associated with highest noise (38 +/- 7.4 HU, p = 0.02). Conclusion: Aortoiliac CTA using dual-source PCD-CT at 40 keV achieved high attenuation and CNR, enabling effective imaging with only 9.8 g of iodine.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Low-dose Ultra-high-resolution Photon-Counting Detector CT for Visceral Artery CT Angiography: A Preliminary Study
    Wang, Lingyun
    Hu, Yangfan
    Zhong, Jingyu
    Yue, Xing
    Xu, Zhihan
    Ding, Bei
    Chu, Jingshen
    Yan, Fuhua
    Yao, Weiwu
    Zhang, Huan
    Hu, Weiguo
    ACADEMIC RADIOLOGY, 2024, 31 (12) : 5087 - 5099
  • [32] Simultaneous high-pitch multi-energy CT pulmonary angiography using a dual-source photon-counting-detector CT: A phantom experiment
    Mihailovic, Jelena M.
    Bruesewitz, Michael R.
    Swicklik, Joseph R.
    Yalon, Mariana
    Rajiah, Prabhakar S.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Yu, Lifeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (11):
  • [33] Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study
    Tao, Shengzhen
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL PHYSICS, 2019, 46 (09) : 4105 - 4115
  • [34] Image quality and dose exposure of contrast-enhanced abdominal CT on a 1st generation clinical dual-source photon-counting detector CT in obese patients vs. a 2nd generation dual-source dual energy integrating detector CT
    Hagen, Florian
    Hofmann, Johannes
    Wrazidlo, Robin
    Gutjahr, Ralf
    Schmidt, Bernhard
    Faby, Sebastian
    Nikolaou, Konstantin
    Horger, Marius
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [35] Visualization of bone details in a novel photon-counting dual-source CT scanner—comparison with energy-integrating CT
    Stefanie J. Bette
    Franziska M. Braun
    Mark Haerting
    Josua A. Decker
    Jan H. Luitjens
    Christian Scheurig-Muenkler
    Thomas J. Kroencke
    Florian Schwarz
    European Radiology, 2022, 32 : 2930 - 2936
  • [36] Low-dose lung cancer screening with photon-counting CT: a feasibility study
    Symons, Rolf
    Cork, Tyler E.
    Sahbaee, Pooyan
    Fuld, Matthew K.
    Kappler, Steffen
    Folio, Les R.
    Bluemke, David A.
    Pourmorteza, Amir
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (01): : 202 - 213
  • [37] Image quality of lung perfusion with photon-counting-detector CT: comparison with dual-source, dual-energy CT
    Remy-Jardin, Martine
    Guiffault, Lucas
    Oufriche, Idir
    Duhamel, Alain
    Flohr, Thomas
    Schmidt, Bernhard
    Remy, Jacques
    EUROPEAN RADIOLOGY, 2024, 34 (12) : 7831 - 7844
  • [38] Multi-Contrast Imaging on Dual-Source Photon-Counting-Detector (PCD) CT
    Tao, Shengzhen
    Rajendran, Kishore
    McCollough, Cynthia H.
    Leng, Shuai
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [39] Low-Dose Scan Protocols in Dual-Source CT Coronary Angiography
    Li, Min
    Sun, Gang
    RADIOLOGY, 2012, 263 (03) : 937 - 938
  • [40] Photon-counting detector CT (PCD-CT) generated iodine maps to characterize parenchymal lung disease: A feasibility study
    Huisinga, C.
    Bredemeier, S.
    Hartung, D.
    Schaefer-Prokop, C.
    Scharm, S.
    Werncke, T.
    Renz, D.
    Wacker, F.
    Shin, H.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181